该回顾性队列研究纳入2008至2017年一所大学医院中有真空吸引助产失败史、随后再次妊娠分娩的166名女性,其中113名(68%)尝试剖宫产后阴道试产(TOLAC),总体成功率为67%;TOLAC失败组新生儿1分钟Apgar评分低于7分和5分钟Apgar评分低于8分的比例均高于成功组,TOLAC组未发生产科肛门括约肌损伤、产后出血和子宫破裂。

要点

  • 有真空吸引助产失败史者再次妊娠TOLAC成功率67%。
  • TOLAC失败组新生儿1分钟Apgar<7分6例(16%)vs 成功组2例(3%),OR 7.16。
  • TOLAC失败组新生儿5分钟Apgar<8分3例(8%)vs 成功组0例(0%),OR 15.5。

核心结论

  • 有真空吸引助产失败史的女性再次妊娠行TOLAC似乎与可接受的TOLAC成功率相关(原文用appears to be associated with an acceptable success rate)。
  • 这些数据应有助于改善患者咨询,并为希望在前次真空吸引助产失败后经阴道分娩者提供信心(原文用should improve patient counseling and provide reassurance)。

研究设计与样本

  • 回顾性队列研究,研究组为2008至2017年在一所大学医院有前次真空吸引助产失败、随后再次分娩的所有女性。
  • 共166名有前次真空吸引助产失败史的女性在研究期间分娩,中位分娩间隔28(21-36)个月。

主要发现

  • 166名女性中53名(32%)行择期重复剖宫产,113名(68%)行TOLAC。
  • 两组产前特征虽有小统计学差异,但无临床显著差异。
  • 113名行TOLAC者总体成功率为67%。
  • TOLAC失败组较成功组新生儿1分钟Apgar评分低于7分者6例(16%)vs 2例(3%),OR 7.16,95% CI 1.36-37.45,P=.01。
  • TOLAC失败组较成功组新生儿5分钟Apgar评分低于8分者3例(8%)vs 0例(0%),OR 15.5,95% CI 1.78-308.7,P=.03。

临床怎么用

  • 原文结论认为有前次真空吸引助产失败史者行TOLAC似乎与可接受的TOLAC成功率相关。
  • 原文认为这些数据应有助于改善患者咨询,并为希望在前次真空吸引助产失败后经阴道分娩者提供信心。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To examine trial of labor after cesarean delivery (TOLAC) success rates and its associated factors among women with a previous failed vacuum-assisted vaginal delivery. METHODS: We conducted a retrospective cohort study. The study group comprised all women with a prior failed vacuum-assisted vaginal delivery who subsequently delivered from 2008 to 2017 at a university hospital. RESULTS: Overall, 166 women with prior history of failed vacuum-assisted vaginal delivery delivered during the study period, with a median interdelivery interval of 28 (21-36) months. Of them, 53 (32%) had an elective repeat cesarean delivery, and 113 (68%) had a TOLAC. Although there were small statistical differences in the predelivery characteristics of the two groups, there were not clinically significant differences. Of the 113 women who underwent TOLAC in the subsequent pregnancy, the overall success rate was 67%. Neonatal 1- and 5-minute Apgar scores were lower among neonates born to women who experienced a failed TOLAC attempt compared with those who underwent successful TOLAC: 1-minute Apgar score less than 7 (6 [16%] vs 2 [3%], odds ratio [OR] 7.16, 95% CI 1.36-37.45, P=.01), 5-minute Apgar score less than 8 (3 [8%] vs 0 [0%], OR 15.5, 95% CI 1.78-308.7, P=.03). No events of obstetric anal sphincter injury, postpartum hemorrhage and uterine rupture were encountered among women who underwent TOLAC. CONCLUSION: Trial of labor after cesarean delivery in women with a previous failed vacuum-assisted vaginal delivery appears to be associated with an acceptable success rate. These data should improve patient counseling and provide reassurance for those who wish to deliver vaginally after a previous failed vacuum-assisted vaginal delivery.