文献速递妇科

术中成像工具诊断子宫内膜异位症的准确性:系统综述与Meta分析

Diagnostic Accuracy of Intraoperative Tools for Detecting Endometriosis: A Systematic Review and Meta-analysis.
PubMed 文献 · J Minim Invasive Gynecol · 2019-11-22

该系统综述与Meta分析检索至2019年2月底,纳入7项研究共472例女性、1717份组织病理标本,评估窄带成像、5-氨基乙酰丙酸诱导荧光、自身荧光成像、吲哚菁绿及三维机器人腹腔镜的诊断准确性。在4项适当进行对照活检的研究(171例女性、448份标本)中,增强成像技术的敏感度和特异度均高于白光检查(分别为0.84和0.89 vs 0.75和0.76,p≤.001)。作者结论认为增强成像可发现白光腹腔镜漏诊的额外病灶,但其对长期术后结局的益处尚未确定,目前这些工具仅应考虑在研究背景下使用。

要点

  • 增强成像技术敏感度0.84、特异度0.89,均高于白光检查的0.75和0.76(p≤.001)。
  • 所有研究中增强成像均诊断出白光检查未发现的额外子宫内膜异位病灶。
  • 不良事件少见(n=5),仅见于使用外源性光敏剂时。

核心结论

  • 增强成像可发现常规白光腹腔镜漏诊的额外子宫内膜异位病灶,但其对长期术后结局的益处尚未确定,目前这些工具仅应在研究背景下考虑使用。

研究设计与样本

  • 系统综述与Meta分析,检索MEDLINE、EMBASE和CENTRAL数据库至2019年2月底,纳入7项随机对照试验或前瞻性队列研究,共472例女性、1717份组织病理标本,以组织病理学评估为标准。

主要发现

  • 在4项适当进行对照活检的研究(171例女性、448份标本)中,增强成像技术的敏感度和特异度分别为0.84和0.89,白光检查分别为0.75和0.76,差异有统计学意义(p≤.001)。
  • 所有研究中,增强成像工具均诊断出白光检查未发现的额外子宫内膜异位病灶。
  • 不良事件少见(n=5),仅在使用外源性光敏剂时报告。
  • 无报告显示因更好检测子宫内膜异位病灶而改善患者报告的长期结局。
  • 4项研究存在高偏倚风险,3项研究未对正常外观腹膜进行活检验证,二者均为显著异质性来源,导致成像工具敏感度被高估、特异度被低估。

关键数值与推荐

  • 增强成像技术敏感度0.84、特异度0.89,白光检查敏感度0.75、特异度0.76(p≤.001)。
  • 纳入研究涉及窄带成像(2项)、5-氨基乙酰丙酸诱导荧光(2项)、自身荧光成像(1项)、吲哚菁绿(1项)和三维机器人腹腔镜(1项)。

临床怎么用

  • 作者认为,增强成像工具目前仅应在研究背景下考虑使用。

局限性

  • 4项研究存在高偏倚风险。
  • 3项研究未对正常外观腹膜进行活检以验证结果。
  • 上述因素为显著异质性来源,导致成像工具敏感度被高估、特异度被低估。
  • 增强成像发现额外病灶对长期术后结局的益处尚未确定。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To evaluate the diagnostic accuracy of intraoperative laparoscopic imaging tools in reference to that of histopathology for detecting endometriotic lesions and to compare them with conventional white-light inspection by performing a systematic review with meta-analysis. DATA SOURCES: We searched the MEDLINE, EMBASE, and CENTRAL databases in addition to citations and reference lists until the end of February 2019. METHODS OF STUDY SELECTION: Two authors screened 1038 citations for eligibility. We included randomized controlled trials or prospective cohort studies published in English, assessing the accuracy of intraoperative imaging tools for diagnosing endometriosis during laparoscopy. We considered studies using histopathologic evaluation as a standard criterion. TABULATION, INTEGRATION, AND RESULTS: Seven studies were eligible, including 472 women and 1717 histopathologic specimens, and they involved study of the use of narrow-band imaging (2 studies), 5-aminolevulinic acid-induced fluorescence (2 studies), autofluorescence imaging (1 study), indocyanine green (1 study), and a 3-dimensional robotic laparoscopy (1 study). Two authors extracted data and assessed the validity of the included studies. Bivariate random-effects models and McNemar's test were used to compare the tests and evaluate sources of heterogeneity. Four studies were attributed a high risk of bias, and biopsies of normal-looking peritoneum were not performed to verify the results in 3 studies; both factors were identified as significant sources of heterogeneity, leading to the overestimation of the sensitivity and underestimation of the specificity of imaging tools. In all studies, additional endometriotic lesions were diagnosed with the enhanced imaging tool compared with white-light inspection alone. In the 4 studies that appropriately performed control biopsies (171 women, 448 specimens), enhanced imaging techniques were associated with a higher sensitivity and specificity compared with white-light inspection (0.84 and 0.89 compared with 0.75 and 0.76, respectively, p ≤.001). Adverse events were uncommon (n = 5) and reported only with the use of exogeneous photosensitizers. There were no reports of long-term changes in patient-reported outcomes arising from better detection of endometriosis lesions. CONCLUSION: Studies report that enhanced imaging allows for the detection of additional endometriotic lesions missed by conventional white-light laparoscopy. The benefits of finding these additional lesions using enhanced imaging compared with white-light inspection alone on long-term postoperative outcomes have not been determined, and these tools should be considered only in a research context at this time.

来源:J Minim Invasive Gynecol,查看原文。版权归原作者所有。

引用

  1. Maheux-Lacroix S, Belanger M, Pinard L, et al. Diagnostic Accuracy of Intraoperative Tools for Detecting Endometriosis: A Systematic Review and Meta-analysis. J Minim Invasive Gynecol. 2019. PMID: 31760118. doi:10.1016/j.jmig.2019.11.010

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。