机械去除玻璃化复苏人囊胚的透明带不影响临床结局
一项前瞻性随机对照研究将419对夫妇分配至透明带去除组(n=209)或透明带完整组(n=210)行玻璃化复苏胚胎移植。结论认为完全机械去除透明带未影响所测试的临床结局参数。
要点
- 前瞻性随机对照研究纳入419对夫妇,比较透明带去除与完整囊胚移植。
核心结论
- 完全机械去除透明带未影响所测试的临床结局参数。
研究设计与样本
- 前瞻性随机对照研究,419对夫妇随机分配至透明带去除组(n=209)或透明带完整组(n=210)行玻璃化复苏胚胎移植。
主要发现
- 两组临床妊娠、着床和持续妊娠率相似。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
RESEARCH QUESTION: Does complete mechanical removal of the zona pellucida modify the outcome of transfer of vitrified-warmed human blastocysts? DESIGN: In a prospective randomized controlled study, 419 couples were allocated to either zona pellucida-free (n = 209) or zona intact (n = 210) vitrified-warmed embryo transfer. Main outcome measures included clinical pregnancy, implantation and ongoing pregnancy rates. RESULTS: Transfer of zona pellucida-free blastocysts resulted in clinical pregnancy, implantation and ongoing pregnancy rates (35,9%, 33,9% and 32,1%, respectively), similar to those achieved with zona intact control embryos (39%, 36,4% and 33,1%, respectively). CONCLUSION: Total mechanical removal of the zona pellucida did not affect the tested parameters of clinical outcomes.
引用
- Kirienko KV, Apryshko VP, Naumova AA, et al. Mechanical zona pellucida removal of vitrified-warmed human blastocysts does not affect the clinical outcome. Reprod Biomed Online. 2019. PMID: 31530444. doi:10.1016/j.rbmo.2019.06.003