三维超声诊断的T形子宫与胚胎移植后不良妊娠结局相关
本研究为前瞻性队列研究的二次分析,纳入648例在胚胎移植前一天行三维超声检查的患者,按宫腔形态分为正常组472例、中间组166例和T形组10例。T形子宫患病率为1.5%,其活产率为40.0%,临床流产风险为40.0%,异位妊娠风险为10.0%,均高于正常组和中间组。结论认为T形子宫与单囊胚移植后不良妊娠结局相关,但需更大样本量化风险。
要点
- T形子宫患病率为1.5%,活产率为40.0%,低于正常组的66.5%和中间组的65.7%。
- T形子宫临床流产率为40.0%,高于正常组的7.0%和中间组的9.0%(P < 0.01)。
- T形子宫异位妊娠率为10.0%,高于正常组的1.1%和中间组的1.9%(P = 0.05)。
核心结论
- T形子宫腔形态与单囊胚移植后不良妊娠结局相关。
- 鉴于该病患病率低,量化风险程度需要更大的患者队列。
研究设计与样本
- 前瞻性队列研究的二次分析,纳入648例在胚胎移植前一天行三维超声检查的患者。
- 按宫腔形态分为正常组472例、中间组166例和T形组10例。
- 采用定量宫腔尺寸评估宫腔形态,比较各组活产、临床流产和异位妊娠结局。
主要发现
- T形子宫患病率为1.5%。
- 宫腔形态与宫口间距与峡部直径比值强烈相关(P < 0.01)。
- 活产率:正常组66.5%,中间组65.7%,T形组40.0%。
- 临床流产率:T形组40.0% vs 正常组7.0% vs 中间组9.0%(P < 0.01)。
- 异位妊娠率:T形组10.0% vs 正常组1.1% vs 中间组1.9%(P = 0.05)。
关键数值与推荐
- 宫口间距与峡部直径比值截断值为2时,对活产有弱预测价值,对临床流产或异位妊娠无预测价值。
临床怎么用
- 原文未据此给出推荐。
局限性
- T形子宫患病率低,量化风险程度需要更大的患者队列。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
RESEARCH QUESTION: Is T-shaped uterine cavity morphology associated with adverse pregnancy outcomes after transfer of a single thawed euploid blastocyst? DESIGN: In this secondary analysis of a prospective cohort study, 648 patients with three-dimensional ultrasound (3D-US) data obtained on the day before embryo transfer were categorized into three groups according to uterine cavity morphology: normal (n = 472), intermediate (n = 166) and T-shaped (n = 10). Quantitative uterine cavity dimensions were used to evaluate uterine cavity morphology. Pregnancy outcomes, including live birth, clinical miscarriage and ectopic pregnancy, were compared among the groups. RESULTS: The prevalence of a T-shaped uterus in this cohort was 1.5%. Uterine cavity morphology was strongly associated with the ratio of interostial distance and isthmic diameter (P < 0.01). Live birth rates were 66.5% for normal, 65.7% for intermediate and 40.0% for T-shaped cavity morphology. Women with a T-shaped uterus had an increased risk of clinical miscarriage (40.0% versus 7.0% for normal and 9.0% for intermediate cavity morphology, P < 0.01) and ectopic pregnancy (10.0% versus 1.1% for normal and 1.9% for intermediate cavity morphology, P = 0.05). When evaluating interostial distance and isthmic diameter ratio to determine pregnancy outcomes, a cut-off value of 2 was noted to have weak predictive value for live birth, but not clinical miscarriage or ectopic pregnancy. CONCLUSIONS: T-shaped uterine cavity morphology is associated with adverse pregnancy outcomes after transfer of a single thawed euploid blastocyst. Given the low prevalence of this condition, quantifying the magnitude of risk will require a larger cohort of patients.
引用
- Neal SA, Morin SJ, Werner MD, et al. Three-dimensional ultrasound diagnosis of T-shaped uterus is associated with adverse pregnancy outcomes after embryo transfer. Reprod Biomed Online. 2019. PMID: 31563452. doi:10.1016/j.rbmo.2019.07.030
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。