文献速递产科母胎医学

小于胎龄儿妊娠中母体血流动力学指标是否为胎儿生长受限的标志物

Are maternal hemodynamic indices markers of fetal growth restriction in pregnancies with a small-for-gestational-age fetus?
PubMed 文献 · Ultrasound Obstet Gynecol · 2020-01-01

前瞻性研究比较102例胎儿生长受限(FGR)、64例小于胎龄儿(SGA)及401例对照妊娠的母体血流动力学。FGR组心率(80 vs 85 bpm)和心输出量(0.91 vs 0.98 MoM)低于对照,平均动脉压、系统血管阻力及子宫动脉搏动指数高于对照;SGA组与对照无显著差异。母体血流动力学指标可能有助于区分FGR与SGA妊娠。

要点

  • FGR妊娠母体心率及心输出量低于对照,平均动脉压、系统血管阻力及子宫动脉阻力高于对照。
  • SGA妊娠无FGR证据者,母体血流动力学指标与对照无显著差异。
  • 母体血流动力学指标可能有助于区分FGR与SGA妊娠。

核心结论

  • FGR妊娠表现为母体血流动力学功能受损,证据为心率及心输出量降低,平均动脉压、系统血管阻力及子宫动脉阻力升高。
  • 分娩SGA新生儿但无FGR证据的妊娠,母体血流动力学功能正常。
  • 母体血流动力学指标可能有助于区分FGR与SGA妊娠。

研究设计与样本

  • 前瞻性研究,纳入血压正常的FGR妊娠102例、SGA胎儿妊娠64例及对照妊娠401例。
  • FGR定义为估测胎儿体重(EFW)小于第3百分位或存在胎盘-胎儿血流受损的多普勒证据;SGA定义为EFW小于第10百分位。
  • 使用无创设备(USCOM-1A®)评估母体血流动力学,经腹超声测量子宫动脉搏动指数(UtA-PI)。
  • 采用设备特异性参考范围校正受孕龄及母体特征影响的血流动力学变量,组间比较采用卡方检验或Mann-Whitney U检验。

主要发现

  • 中位孕龄36周;FGR组及SGA组孕妇身高及体重均低于对照组。
  • 与对照组相比,FGR组中位母体心率较低(80 bpm vs 85 bpm;P=0.001),心输出量MoM较低(0.91 vs 0.98;P=0.003)。
  • 与对照组相比,FGR组中位母体平均动脉压较高(90 mmHg vs 87 mmHg;P=0.040),系统血管阻力MoM较高(1.2 vs 1.0;P<0.001),UtA-PI MoM较高(1.1 vs 0.96;P<0.001)。
  • FGR组与对照组相比,每搏输出量MoM无显著差异(1.0 vs 0.98;P=0.647)。
  • 与SGA组相比,FGR组中位心率较低(80 bpm vs 87 bpm;P=0.022),中位平均动脉压较高(90 mmHg vs 85 mmHg;P=0.025),系统血管阻力MoM较高(1.2 vs 1.0;P=0.002),UtA-PI MoM较高(1.1 vs 0.98;P=0.005)。

临床怎么用

  • 作者认为母体血流动力学指标可能有助于区分FGR与SGA妊娠。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Pregnancies complicated by fetal growth restriction (FGR) have a worse outcome than those with a small-for-gestational-age (SGA) fetus. There is increasing evidence of a maternal cardiovascular role in the pathophysiology of FGR. We aimed to compare maternal hemodynamic indices between pregnancies complicated by FGR and those delivering a SGA neonate, using a non-invasive device. METHODS: This was a prospective study of normotensive pregnancies complicated by FGR (defined as estimated fetal weight (EFW) < 3rd centile or Doppler evidence of impaired placental-fetal blood flow), those with a SGA fetus (defined as EFW < 10th centile) and control pregnancies with an appropriately grown fetus. Assessment of maternal hemodynamics (heart rate (HR), cardiac output (CO), mean arterial pressure (MAP), systemic vascular resistance (SVR) and stroke volume) was performed using a non-invasive device (USCOM-1A®). Uterine artery (UtA) pulsatility index (PI) was measured using transabdominal ultrasound. Hemodynamic variables that are affected by gestational age and maternal characteristics were corrected for using device-specific reference ranges. Comparison between groups was performed using the chi-square test or the Mann-Whitney U-test, as appropriate. RESULTS: A total of 102 FGR, 64 SGA and 401 control pregnancies, with a median gestational age of 36 weeks, were included in the analysis. Women with a pregnancy complicated by FGR and those with a SGA fetus were shorter and weighed less than did controls. Compared with controls, the FGR group had significantly lower median maternal HR (80 beats per min (bpm) vs 85 bpm; P = 0.001) and CO multiples of the median (MoM; 0.91 vs 0.98; P = 0.003), and higher median maternal MAP (90 mmHg vs 87 mmHg; P = 0.040), SVR MoM (1.2 vs 1.0; P < 0.001) and UtA-PI MoM (1.1 vs 0.96; P < 0.001), but there was no significant difference in stroke volume MoM (1.0 vs 0.98; P = 0.647). Compared with the SGA group, the FGR group had a significantly lower median HR (80 bpm vs 87 bpm; P = 0.022), and higher median maternal MAP (90 mmHg vs 85 mmHg; P = 0.025), SVR MoM (1.2 vs 1.0; P = 0.002) and UtA-PI MoM (1.1 vs 0.98; P = 0.005), but there was no significant difference in CO MoM (0.91 vs 0.96; P = 0.092) or stroke volume MoM (1.0 vs 1.0; P = 0.806). There were no significant differences in adjusted maternal hemodynamic indices between the SGA group and controls. CONCLUSION: Pregnancies complicated by FGR presented with impaired maternal hemodynamic function, as evidenced by lower HR and CO, as well as higher MAP, SVR and UtA resistance. Pregnancies delivering a SGA neonate, without evidence of FGR, had normal maternal hemodynamic function. Maternal hemodynamic indices may therefore be of value in distinguishing FGR from SGA pregnancies. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Perry H, Lehmann H, Mantovani E, et al. Are maternal hemodynamic indices markers of fetal growth restriction in pregnancies with a small-for-gestational-age fetus? Ultrasound Obstet Gynecol. 2020. PMID: 31381215. doi:10.1002/uog.20419

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。