使用5-氨基乙酰丙酸的宫腔镜光动力诊断:一种高灵敏度的子宫内膜恶性疾病诊断方法
本研究为单中心、开放标签、探索性干预研究,纳入34例在庆应义塾大学医院妇产科行宫腔镜切除术的患者,术前约3小时口服5-氨基乙酰丙酸(5ALA),术中行5ALA光动力诊断(PDD)并活检。5ALA-PDD诊断宫腔内恶性的敏感度为93.8%、特异度为51.9%;基于R/B和G/B比值的逻辑回归模型曲线下面积为0.838, cutoff值0.220时敏感度90.6%、特异度65.4%。作者认为宫腔镜5ALA-PDD对微小病灶诊断可能有帮助。
要点
- 5ALA-PDD诊断宫腔恶性的敏感度为93.8%,特异度为51.9%。
- 恶性病变的R/B比值最高,依次高于良性病变和正常子宫组织,组间差异有统计学意义(p<.05)。
- 预测模型曲线下面积为0.838,cutoff值0.220时敏感度90.6%、特异度65.4%。
核心结论
- 据作者所知,这是首项关于5ALA-PDD诊断宫腔内恶性肿瘤准确性的研究。
- 宫腔镜5ALA-PDD具有较高的敏感度和病灶可识别性。
- 这些发现提示宫腔镜5ALA-PDD可能有助于微小病灶的诊断。
研究设计与样本
- 单中心、开放标签、探索性干预研究,设置于日本一所大学医院。
- 纳入34例在庆应义塾大学医院妇产科行宫腔镜切除术的患者。
- 患者术前约3小时口服5ALA,术中行宫腔观察和子宫内膜活检,标本行组织病理学诊断。
- 因内镜系统故障排除3例,最终经内镜采集113份标本。
主要发现
- 5ALA-PDD诊断宫腔内恶性的敏感度为93.8%,特异度为51.9%。
- 影像分析中R/B比值在恶性病变最高,其次为良性病变和正常子宫组织,组间差异有统计学意义(p<.05)。
- 基于逻辑回归用R/B和G/B比值构建恶性预测公式,其受试者工作特征曲线下面积为0.838。
- 公式cutoff值为0.220时,诊断恶性疾病的敏感度为90.6%,特异度为65.4%。
关键数值与推荐
- 5ALA-PDD诊断宫腔内恶性的敏感度为93.8%,特异度为51.9%。
- 预测公式cutoff值0.220时,诊断恶性疾病的敏感度为90.6%,特异度为65.4%,曲线下面积为0.838。
临床怎么用
- 作者认为宫腔镜5ALA-PDD可能有助于微小病灶的诊断。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
STUDY OBJECTIVE: To examine the diagnostic accuracy of hysteroscopic photodynamic diagnosis (PDD) using 5-aminolevulinic acid (5ALA) in patients with endometrial cancer and premalignant atypical endometrial hyperplasia. DESIGN: A single-center, open-label, exploratory intervention study. SETTING: University Hospital in Japan. PATIENTS: Thirty-four patients who underwent hysteroscopic resection in the Department of Obstetrics and Gynecology at Keio University Hospital. INTERVENTIONS: Patients were given 5ALA orally approximately 3 hours before surgery and underwent observation of the uterine cavity and endometrial biopsy using 5ALA-PDD during hysteroscopic resection. Specimens were diagnosed histopathologically and the diagnostic sensitivity and specificity of hysteroscopic 5ALA-PDD for malignancy in the uterine cavity was determined. Red (R), blue (B), and green (G) intensity values were determined from PDD images, and the relationships of histopathological diagnosis with these values were used to develop a model for objective diagnosis of uterine malignancy. MEASUREMENTS AND MAIN RESULTS: Three patients were excluded from the study because of failure of the endoscope system. A total of 113 specimens were collected endoscopically. The sensitivity and specificity of 5ALA-PDD for diagnosis of malignancy in the uterine cavity were 93.8% and 51.9%, respectively. The R/B ratio in imaging analysis was highest in malignant lesions, followed by benign lesions and normal uterine tissue, with significant differences among these groups (p <.05). The R/B and G/B ratios were used in a formula for prediction of malignancy based on logistic regression and the area under the receiver operating characteristic curve for this formula was 0.838. At a formula cutoff value of 0.220, the sensitivity and specificity for diagnosis of malignant disease were 90.6% and 65.4%, respectively. CONCLUSION: To our knowledge, this is the first study of the diagnostic accuracy of 5ALA-PDD for malignancies in the uterine cavity. Hysteroscopic 5ALA-PDD had higher sensitivity and identifiability of lesions. These findings suggest that hysteroscopic 5ALA-PDD may be useful for diagnosis of minute lesions.
引用
- Matoba Y, Banno K, Kisu I, et al. Hysteroscopic Photodynamic Diagnosis Using 5-Aminolevulinic Acid: A High-Sensitivity Diagnostic Method for Uterine Endometrial Malignant Diseases. J Minim Invasive Gynecol. 2019. PMID: 31415818. doi:10.1016/j.jmig.2019.08.012
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。