文献速递产科母胎医学

常规孕晚期超声预测大于胎龄儿

Prediction of large-for-gestational-age neonate by routine third-trimester ultrasound.
PubMed 文献 · Ultrasound Obstet Gynecol · 2019-07-23

本回顾性研究基于21 989例和45 847例单胎妊娠数据,比较孕31+0至33+6周与35+0至36+6周超声估计胎儿体重(EFW)和腹围(AC)预测大于胎龄儿(LGA)的性能。结果显示EFW优于AC,36周优于32周,EFW>90百分位预测性能中等,并提出36周EFW>70百分位筛查、38周EFW>85百分位考虑医源性分娩的两阶段策略。

要点

  • 孕35+0至36+6周EFW预测LGA优于孕31+0至33+6周,EFW优于AC。
  • EFW>90百分位筛查LGA的预测性能中等,筛查阳性率10%时检出率46%~65%。
  • 作者提出36周EFW>70百分位筛查、38周EFW>85百分位考虑医源性分娩的两阶段策略。

核心结论

  • 孕晚期超声预测LGA的性能在36周高于32周、EFW高于AC、出生体重>97百分位高于>90百分位、分娩在10天内高于之后任何时间。
  • EFW>90百分位预测LGA性能中等,本研究提出两阶段策略以提高产前预测。

研究设计与样本

  • 回顾性研究,比较21 989例和45 847例单胎妊娠的EFW与AC预测性能。
  • 14 497例单胎妊娠用于多变量logistic回归分析生长速度的附加价值。
  • 45 847例妊娠数据库用于计算不同EFW百分位切点的筛查阳性率和检出率。

主要发现

  • EFW Z-score的AUC显著高于AC Z-score,35+0至36+6周显著高于31+0至33+6周(P<0.001)。
  • 35+0至36+6周EFW Z-score筛查LGA的性能未因加入EFW或AC生长速度而显著改善。
  • 35+0至36+6周EFW>90百分位筛查≥37周LGA,筛查阳性率10%时,出生体重>97和>90百分位儿的检出率分别为65%和46%。
  • 同前筛查≤10天内分娩的LGA,筛查阳性率11%时,出生体重>97和>90百分位儿的检出率分别为84%和71%。
  • 35+0至36+6周EFW>70百分位筛查≥37周LGA,筛查阳性率32%时,出生体重>97和>90百分位儿的检出率分别为91%和82%。

关键数值与推荐

  • 孕36周常规胎儿生物测量作为巨大儿筛查而非诊断试验。
  • EFW>70百分位用于识别需在38周再次扫描的妊娠。
  • 38周扫描EFW>85百分位者应考虑在38周内医源性分娩。

临床怎么用

  • 孕36周常规超声EFW>70百分位者应在38周复查超声。
  • 38周超声EFW>85百分位者作者建议可考虑医源性分娩。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: First, to evaluate and compare the performance of routine ultrasonographic estimated fetal weight (EFW) and fetal abdominal circumference (AC) at 31 + 0 to 33 + 6 and 35 + 0 to 36 + 6 weeks' gestation in the prediction of a large-for-gestational-age (LGA) neonate born at ≥ 37 weeks' gestation. Second, to assess the additive value of fetal growth velocity between 32 and 36 weeks' gestation to the performance of EFW at 35 + 0 to 36 + 6 weeks' gestation for prediction of a LGA neonate. Third, to define the predictive performance for a LGA neonate of different EFW cut-offs on routine ultrasound examination at 35 + 0 to 36 + 6 weeks' gestation. Fourth, to propose a two-stage strategy for identifying pregnancies with a LGA fetus that may benefit from iatrogenic delivery during the 38th gestational week. METHODS: This was a retrospective study. First, data from 21 989 singleton pregnancies that had undergone routine ultrasound examination at 31 + 0 to 33 + 6 weeks' gestation and 45 847 that had undergone routine ultrasound examination at 35 + 0 to 36 + 6 weeks were used to compare the predictive performance of EFW and AC for a LGA neonate with birth weight > 90th and > 97th percentiles born at ≥ 37 weeks' gestation. Second, data from 14 497 singleton pregnancies that had undergone routine ultrasound examination at 35 + 0 to 36 + 6 weeks' gestation and had a previous scan at 30 + 0 to 34 + 6 weeks were used to determine, through multivariable logistic regression analysis, whether addition of growth velocity, defined as the difference in EFW Z-score or AC Z-score between the early and late third-trimester scans divided by the time interval between the scans, improved the performance of EFW at 35 + 0 to 36 + 6 weeks in the prediction of delivery of a LGA neonate at ≥ 37 weeks' gestation. Third, in the database of the 45 847 pregnancies that had undergone routine ultrasound examination at 35 + 0 to 36 + 6 weeks' gestation, the screen-positive and detection rates for a LGA neonate born at ≥ 37 weeks' gestation and ≤ 10 days after the initial scan were calculated for different EFW percentile cut-offs between the 50th and 90th percentiles. RESULTS: First, the areas under the receiver-operating characteristics curves (AUC) of screening for a LGA neonate were significantly higher using EFW Z-score than AC Z-score and at 35 + 0 to 36 + 6 than at 31 + 0 to 33 + 6 weeks' gestation (P < 0.001 for all). Second, the performance of screening for a LGA neonate achieved by EFW Z-score at 35 + 0 to 36 + 6 weeks was not significantly improved by addition of EFW growth velocity or AC growth velocity. Third, in screening by EFW > 90th percentile at 35 + 0 to 36 + 6 weeks' gestation, the predictive performance for a LGA neonate born at ≥ 37 weeks' gestation was modest (65% and 46% for neonates with birth weight > 97th and > 90th percentiles, respectively, at a screen-positive rate of 10%), but the performance was better for prediction of a LGA neonate born ≤ 10 days after the scan (84% and 71% for neonates with birth weight > 97th and > 90th percentiles, respectively, at a screen-positive rate of 11%). Fourth, screening by EFW > 70th percentile at 35 + 0 to 36 + 6 weeks' gestation predicted 91% and 82% of LGA neonates with birth weight > 97th and > 90th percentiles, respectively, born at ≥ 37 weeks' gestation, at a screen-positive rate of 32%, and the respective values of screening by EFW > 85th percentile for prediction of a LGA neonate born ≤ 10 days after the scan were 88%, 81% and 15%. On the basis of these results, it was proposed that routine fetal biometry at 36 weeks' gestation is a screening rather than diagnostic test for fetal macrosomia and that EFW > 70th percentile should be used to identify pregnancies in need of another scan at 38 weeks, at which those with EFW > 85th percentile should be considered for iatrogenic delivery during the 38th week. CONCLUSIONS: First, the predictive performance for a LGA neonate by routine ultrasonographic examination during the third trimester is higher if the scan is carried out at 36 than at 32 weeks, the method of screening is EFW than fetal AC, the outcome measure is birth weight > 97th than > 90th percentile and if delivery occurs within 10 days than at any stage after assessment. Second, prediction of a LGA neonate by EFW > 90th percentile is modest and this study presents a two-stage strategy for maximizing the prenatal prediction of a LGA neonate. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Khan N, Ciobanu A, Karampitsakos T, et al. Prediction of large-for-gestational-age neonate by routine third-trimester ultrasound. Ultrasound Obstet Gynecol. 2019. PMID: 31236963. doi:10.1002/uog.20377

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。