估计胎儿体重低于第十百分位胎儿四腔心切面大小与形态研究
本研究回顾性分析50例估测胎儿体重低于第十百分位、孕25至37周的胎儿,测量四腔心切面大小、形态及心室面积。结果显示无论脐动脉搏动指数和脑胎盘率是否正常,四腔心切面大小和形态异常率均较高,正常脐动脉搏动指数组中80%存在至少一项异常。
要点
- 估测胎儿体重低于第十百分位者四腔心切面大小和形态异常率较高。
- 脐动脉搏动指数和脑胎盘率正常的胎儿中80%存在至少一项四腔心异常。
- 脐动脉搏动指数异常者心室面积及右室/左室面积比异常率较高。
核心结论
- 估测胎儿体重低于第十百分位胎儿四腔心切面大小和形态异常率较高,与脐动脉搏动指数和脑胎盘率测量值无关。
- 脐动脉搏动指数正常而脑胎盘率异常的胎儿四腔心切面测量值更大、更宽,形态较对照组更呈球形或圆形。
- 这些胎儿围产期并发症及儿童和/或成年心血管疾病风险可能增加。
研究设计与样本
- 回顾性研究,纳入50例孕25至37周、估测胎儿体重低于第十百分位的胎儿,分析其最后一次检查数据。
主要发现
- 50例中50%(n=25)脐动脉搏动指数和脑胎盘率正常,该组四腔心切面大小和形态异常显著多于对照组(P<0.02至P<0.0001)。
- 脐动脉搏动指数和脑胎盘率正常组中,44%四腔心切面面积大于第90百分位,32%整体球形指数低于第10百分位,56%四腔心切面宽度大于第90百分位,80%存在至少一项大小和/或形态异常。
- 另50%(n=25)脐动脉搏动指数和/或脑胎盘率一项或两项异常,该组四腔心切面面积大于第90百分位者36%、整体球形指数低于第10百分位者28%、宽度大于第90百分位者68%,均显著高于对照组(P<0.05至P<0.0001)。
- 仅脐动脉搏动指数异常胎儿心室大小有显著变化:56%左心室面积低于第10百分位,28%右心室面积低于第10百分位,36%右室/左室面积比大于第90百分位。
- 上述异常测量中至少一项存在于92%的胎儿。
关键数值与推荐
- 脐动脉搏动指数大于第90百分位和脑胎盘率低于第10百分位定义为异常。
- 以对照胎儿数据将各心脏测量值按小于第10百分位或大于第90百分位分类。
临床怎么用
- 源自四腔心切面的筛查工具可作为心室功能不全的替代指标,可能识别可从进一步全面检查和未来预防性干预中获益的胎儿。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Fetuses with an estimated fetal weight below the 10th centile have an increased risk of adverse perinatal and long-term outcomes as well as increased rates of cardiac dysfunction, which often alters cardiac size and shape of the 4-chamber view and the individual ventricles. As a result, a simple method has emerged to screen for potential cardiac dysfunction in fetuses with estimated fetal weights <10th centile by measuring the size and shape of the 4-chamber view and the size of the ventricles. OBJECTIVE: To determine the number of fetuses with an abnormal size and shape of the 4-chamber view and size of the ventricles in fetuses with an estimated fetal weight <10th centile. MATERIALS AND METHODS: This was a retrospective study of 50 fetuses between 25 and 37 weeks of gestation with an estimated fetal weight <10th centile. Data from their last examination were analyzed. From an end-diastolic image of the 4-chamber view, the largest basal-apical length and transverse width were measured from their corresponding epicardial borders. This allowed the 4-chamber view area and global sphericity index (4-chamber view length/4-chamber view width) to be computed. In addition, tracing along the endocardial borders with speckle tracking software enabled measurements of the right and left ventricular chamber areas and the right ventricle/left ventricle area ratios to be computed. Doppler waveform pulsatility indices from the umbilical (umbilical artery pulsatility index) and middle cerebral arteries (middle cerebral artery pulsatility index) were analyzed, and the cerebroplacental ratio (middle cerebral artery pulsatility index/umbilical artery pulsatility index) computed. Umbilical artery pulsatility indices >90th and cerebroplacental ratios <10th centile were considered abnormal. Using data from the control fetuses, the centile for each of the cardiac measurements was categorized by whether it was <10th or >90th centile, depending upon the measurement. RESULTS: Of the 50 fetuses with estimated fetal weight <10th centile, 50% (n = 25) had a normal umbilical artery pulsatility index and cerebroplacental ratio. These fetuses had significantly more (P < 0.02 to <0.0001) abnormalities of the size and shape of the 4-chamber view than controls. In all, 44% had a 4-chamber view area >90th centile, 32% had a 4-chamber view global sphericity index <10th centile, 56% had a 4-chamber view width >90th centile, and 80% had 1 or more abnormalities of size and/or shape. The remaining 50% of fetuses (n = 25) had abnormalities of 1 or both for the umbilical artery pulsatility index and/or cerebroplacental ratio. These fetuses had significantly higher rates of abnormalities (P <0.05 to <0.0001) than controls for the following 4-chamber view measurements: 36% had a 4-chamber view area >90th centile; 28% had a 4-chamber view global sphericity index <10th centile; and 68% had a 4-chamber view width >90th centile. Only those fetuses with an abnormal umbilical artery pulsatility index had significant changes in ventricular size; 56% had a left ventricular area <10th centile; 28% had a right ventricular area <10th centile; 36% had right ventricular/left ventricular area ratio >90th centile. One or more of the above abnormal measurements were present in 92% of the fetuses. CONCLUSION: Higher rates of abnormalities of cardiac size and shape of the 4-chamber view were found in fetuses with an estimated fetal weight <10th centile, regardless of their umbilical artery pulsatility index and cerebroplacental ratio measurements. Those with a normal umbilical artery pulsatility index and an abnormal cerebroplacental ratio had larger and wider measurements of the 4-chamber view. In addition, the shape of the 4-chamber view was more globular or round than in controls. These fetuses may have an increased risk of perinatal complications and childhood and/or adult cardiovascular disease. Screening tools derived from the 4-chamber view, acting as surrogates for ventricular dysfunction, may identify fetuses who could benefit from further comprehensive testing and future preventive interventions.
引用
- Hobbins JC, Gumina DL, Zaretsky MV, et al. Size and shape of the four-chamber view of the fetal heart in fetuses with an estimated fetal weight less than the tenth centile. Am J Obstet Gynecol. 2019. PMID: 31207236. doi:10.1016/j.ajog.2019.06.008