超声医师特征与初级产前保健中心胎儿颈项透明层测量质量更高的关系
在加泰罗尼亚卫生研究所14个初级产前保健中心,对102名超声医师的16448次颈项透明层(NT)测量计算中位数MoM,中位NT MoM为0.94。46%的超声医师存在NT低估;年超声量超过230次、完成FMF在线课程、接受定期审核及经验更丰富者低估频率更低。
要点
- 14个初级产前保健中心102名超声医师共16448次NT测量,中位NT MoM为0.94。
- 46%的超声医师存在NT低估,年超声量超过230次者低估频率26% vs 53%(p=.022)。
- 完成FMF在线课程者低估22% vs 54%(p=.021),接受定期审核者24% vs 56%(p=.021)。
核心结论
- 年超声量更多、扫描经验更丰富、完成FMF在线课程及接受定期审核的超声医师,其NT测量质量更高。
研究设计与样本
- 对加泰罗尼亚卫生研究所14个参与初级产前保健中心的102名超声医师进行调查,计算每名医师NT测量的中位数MoM。
主要发现
- 16448次NT测量的中位NT MoM为0.94,46%的超声医师存在NT低估。
- 年超声量超过230次的医师低估频率26% vs 年超声量不超过230次者53%(p=.022)。
- 完成FMF在线课程的医师低估频率22% vs 未完成者54%(p=.021)。
- 接受定期审核的医师低估频率24% vs 未接受者56%(p=.021)。
- 随着经验年限增加,低估率从不足5年者的60%降至6至15年者的33%和超过15年者的14%(p=.029)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To assess the quality of nuchal translucency (NT) measurements in primary care and the sonologist's characteristics related with a higher quality. METHODS: The median NT expressed in multiples of the median (MoM) was calculated for each sonologist of 14 participating antenatal primary care centers of the Catalan Institute of Health. A survey to the sonologists was used to establish variables related to higher-quality measurements. RESULTS: The median NT MoM obtained in 16 448 NT measurements, performed by 102 sonologists, was 0.94 MoM. NT underestimation was observed in 46% of the sonologists. Underestimation were less frequent among professionals who performed more than 230 ultrasounds per year (26% vs 53%;p = .022), those who completed the online Fetal Medicine Foundation (FMF) course (22% vs 54%; p = .021), and those who were subject to periodic audits (24% vs 56%; p = .021). Underestimation rate decreased from 60%, to 33% and 14% with the increase of the years of experience from less than 5 years, to 6 to 15 years and more than 15 years of experience, respectively (p = .029). CONCLUSIONS: Higher-quality measurements were demonstrated in sonologists who performed more ultrasounds per year, those with more years of scanning experience, those who completed the online FMF course, and those periodically audited.
引用
- Torrent A, Manrique G, Gómez-Castelló T, et al. Sonologist's characteristics related to a higher quality in fetal nuchal translucency measured in primary antenatal care centers. Prenat Diagn. 2019. PMID: 31237971. doi:10.1002/pd.5512
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。