文献速递产科

引产产妇需剖宫产者与经阴道分娩者的超声判定产程进展不同

Labor progress determined by ultrasound is different in women requiring cesarean delivery from those who experience a vaginal delivery following induction of labor.
PubMed 文献 · Am J Obstet Gynecol · 2019-05-30

该前瞻性纵向研究纳入2016年12月至2017年12月315例足月引产单胎孕妇,系列经会阴超声评估胎头下降,比较阴道分娩与剖宫产者的产程进展差异。需剖宫产者旁矢状角进展斜率更平缓,联合母体特征与旁矢状角时间变化预测因产程停滞需剖宫产的曲线下面积为0.85(95%CI 0.76-0.94),敏感度79%、特异度80%。

要点

  • 需剖宫产者旁矢状角进展与头会阴距离变化斜率较阴道分娩者更平缓。
  • 胎头位置每增加1单位,剖宫产组旁矢状角额外减少5.11度(P<.01)。
  • 联合母体特征与旁矢状角时间变化预测剖宫产的曲线下面积为0.85。

核心结论

  • 系列产时经会阴超声评估胎头下降可客观显示阴道分娩与剖宫产产妇的产程进展差异,该工具可能预测因产程停滞需剖宫产的产妇。

研究设计与样本

  • 前瞻性纵向研究,纳入2016年12月至2017年12月315例足月引产单胎孕妇。
  • 引产开始后系列配对行阴道检查评估宫颈扩张与胎头位置、经会阴超声评估旁矢状角与头会阴距离。
  • 按医院方案,潜伏期每24小时、活跃期每4小时评估一次,研究者与临床团队互相设盲,重复测量数据采用混合效应模型分析。

主要发现

  • 配对阴道检查与超声评估共1198次,每例中位3次,评估间隔中位4.6小时(四分位距4.3-5.1小时)。
  • 阴道分娩组(n=261)旁矢状角及头会阴距离对胎头位置和宫颈扩张的斜率均较剖宫产组(n=54)更陡。
  • 校正个体重复测量与混杂因素后,胎头位置每增加1单位,剖宫产组旁矢状角额外减少5.11度(P<.01);宫颈扩张每增加1单位,额外减少1.37度(P=.01)。
  • 胎头位置每增加1单位,剖宫产组头会阴距离额外增加0.27 cm(P<.01);宫颈扩张每增加1单位,额外增加0.12 cm(P<.01)。
  • 联合母体特征与胎头位置每增加1单位时旁矢状角的时间变化,预测因产程停滞需剖宫产的曲线下面积为0.85(95%CI 0.76-0.94),敏感度79%、特异度80%。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The diagnosis of labor dystocia generally is determined by the deviation of labor progress, which is assessed by the use of a partogram. Recently, intrapartum transperineal ultrasound for the assessment of fetal head descent has been introduced to assess labor progress in the first stage of labor in a more objective and noninvasive way. OBJECTIVE: The objective of the study was to determine the differences in labor progress by the use of serial transperineal ultrasound assessment of fetal head descent between women having vaginal and cesarean delivery. STUDY DESIGN: This was a prospective longitudinal study performed in 315 women with singleton pregnancy who were undergoing labor induction at term between December 2016 and December 2017. Paired assessment of cervical dilation and fetal head station by vaginal examination and transperineal ultrasonographic assessment of parasagittal angle of progression and head-perineum distance were made serially after the commencement of labor induction. According to the hospital protocol, assessment was performed every 24 hours and 4 hours, respectively, during latent and active phases of labor. The researchers and the clinical team were blinded to each other's findings. The repeated measures data were analyzed by mixed effect models. To determine the effect of mode of delivery on the association between parasagittal angle of progression and head-perineum distance against fetal head station and cervical dilation, the significance of the interaction term between each mode of delivery and fetal head station or cervical dilation was determined, which accounted for parity and obesity. Area under receiver-operating characteristic curve was used to evaluate the performance of serial intrapartum sonography in predicting women with cesarean delivery because of failure to progress. RESULTS: The total number of paired vaginal examination and ultrasound assessments was 1198, with a median of 3 per woman. The median assessment-to-assessment interval was 4.6 hours (interquartile range, 4.3-5.1 hours). Women who achieved vaginal delivery (n=261) had steeper slopes of parasagittal angle of progression and head-perineum distance against fetal head station and cervical dilation than those who achieved cesarean delivery (n=54). Objectively, an additional decrease of 5.11 and 1.37 degrees in parasagittal angle of progression was observed for an unit increase in fetal head station and cervical dilation, respectively, in women who required cesarean delivery (P<.01; P=.01), compared with women who achieved vaginal delivery, after taking account of repeated measures from individuals and confounding factors. The respective additional increases in head-perineum distance for a unit increase in fetal head station and cervical dilation were 0.27 cm (P<.01) and 0.12 cm (P<.01). A combination of maternal characteristics with the temporal changes of parasagittal angle of progression for an unit increase in fetal head station achieved an area under receiver-operating characteristic curve of 0.85 (95% confidence interval, 0.76-0.94), with sensitivity of 79% and specificity of 80%, for the prediction of women who required cesarean delivery because of failure to progress. CONCLUSION: The differences in labor progress between vaginal and cesarean delivery have been illustrated objectively by serial intrapartum transperineal ultrasonographic assessment of fetal head descent. This tool is potentially predictive of women who will require cesarean delivery because of failure to progress.

来源:Am J Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Tse WT, Chaemsaithong P, Chan WWY, et al. Labor progress determined by ultrasound is different in women requiring cesarean delivery from those who experience a vaginal delivery following induction of labor. Am J Obstet Gynecol. 2019. PMID: 31153931. doi:10.1016/j.ajog.2019.05.040

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。