母体心脏参数有助于区分子痫前期的临床特征并预测从轻度向重度进展
这项前瞻性队列研究纳入38例子痫前期孕妇和61例血压正常孕妇,用超声心输出量监测系统比较血流动力学参数。合并小于胎龄儿或早发型子痫前期者心输出量低于对照,全身血管阻力均高于对照;轻度子痫前期中进展为重度者血流动力学参数与稳定者显著不同,全身血管阻力Z评分联合子宫动脉搏动指数Z评分预测进展的敏感度95%、特异度80%(曲线下面积0.90)。
要点
- 合并小于胎龄儿或早发型子痫前期者心输出量低于正常孕妇,全身血管阻力高于正常孕妇。
- 早发型与晚发型子痫前期之间、合并小于胎龄儿与适于胎龄儿子痫前期之间心脏参数基本相似。
- 全身血管阻力Z评分联合子宫动脉搏动指数Z评分预测轻度子痫前期进展为重度:敏感度95%、特异度80%。
核心结论
- 评估母体心血管系统可能帮助临床医生识别胎盘受损更严重的子痫前期患者亚群,并可能预测临床起病时为轻度的子痫前期进展为重度的可能性。
研究设计与样本
- 前瞻性队列研究,使用超声心输出量监测系统比较子痫前期孕妇与健康血压正常孕妇(按1:2比例入组对照)的血流动力学参数。
- 共纳入38例子痫前期孕妇和61例血压正常孕妇。
- 子痫前期孕妇按早发型(<34周妊娠)与晚发型(≥34周妊娠)分组,并按合并小于胎龄儿或适于胎龄儿分组进行比较。
- 比较临床起病时为轻度且保持稳定者与进展为重度者的血流动力学特征。
主要发现
- 合并小于胎龄儿子痫前期组、合并适于胎龄儿子痫前期组与对照组全身血管阻力分别为1580.6 ± 483.2、1479.1 ± 433.3、1105.3 ± 293.1(P < .0001)。
- 合并小于胎龄儿子痫前期组心输出量低于对照组(5.7 ± 1.5 vs 6.5 ± 1.3,P = .02)。
- 合并小于胎龄儿子痫前期组与合并适于胎龄儿子痫前期组心脏参数相似,仅前者每搏输出量较低(64.8 ± 24.4 vs 75.2 ± 17.8,P = .04)。
- 早发型子痫前期组、晚发型子痫前期组与对照组全身血管阻力分别为1559.5 ± 528.3、1488.5 ± 292.9、1105.3 ± 293.1(P < .001);仅早发型组心输出量低于对照组(5.5 ± 1.2,P = .02)。
- 早发型与晚发型子痫前期之间母体心脏参数相似。
关键数值与推荐
- 心输出量Z评分、全身血管阻力Z评分、子宫动脉搏动指数Z评分预测进展的敏感度分别为80%、75%、80%,特异度分别为73%、73%、74%。
- 全身血管阻力Z评分联合子宫动脉搏动指数Z评分预测进展为重度:敏感度95%、特异度80%(曲线下面积0.90)。
临床怎么用
- 原文结论认为评估母体心血管系统可能帮助临床医生识别胎盘受损更严重的子痫前期患者亚群。
- 原文结论认为评估母体心血管系统可能预测临床起病时为轻度的子痫前期进展为重度的可能性。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: A primary role of maternal heart dysfunction in the pathophysiology of preeclampsia had been previously advocated although if contradictory results have been reported. OBJECTIVES: The objectives of the study were to describe maternal hemodynamic parameters according to 2 main preeclampsia phenotypes and to investigate whether cardiac findings may be helpful in characterizing the severity and the progression of the disease. STUDY DESIGN: This was a prospective cohort study. We used an ultrasonic cardiac output monitor system to compare the hemodynamic parameters of women with preeclampsia with a group of healthy normotensive women enrolled as controls with a ratio of 1:2. Cardiac output, systemic vascular resistance, and stroke volume were compared among controls and preeclamptic women who were grouped in accordance to the following characteristics: early preeclampsia (<34 weeks' gestation) vs late preeclampsia onset (≥34 weeks' gestation); preeclampsia associated with appropriate for gestational age or small-for-gestational-age newborns. Hemodynamic characteristics were also compared between preeclamptic women with a mild form vs those who progressed toward a severe form. RESULTS: A total of 38 preeclamptic women and 61 normotensive women were included in the study. Both cases of preeclampsia associated with small-for-gestational-age neonates as those with normal-sized ones showed higher systemic vascular resistance compared with the control group (respectively, 1580.6 ± 483.2 vs 1479.1 ± 433.3 vs 1105.3 ± 293.1; P < .0001), while a lower cardiac output was reported only for preeclamptic women with small-for-gestational-age neonates compared with controls (5.7 ± 1.5 vs 6.5 ± 1.3; P = .02). Maternal cardiac parameters were comparable between these 2 groups of preeclamptic women (small-for-gestational-age vs appropriate-for-gestational-age preeclampsia) with the exception of a lower stroke volume in the former one (64.8 ± 24.4 vs 75.2 ± 17.8; P = .04). Similarly, women with both early and late preeclampsia showed higher systemic vascular resistance compared with controls (1559.5 ± 528.3 vs 1488.5 ± 292.9 vs 1105.3 ± 293.1, respectively; P < .001), while a lower cardiac output was noted only in the early-onset group compared with controls (5.5 ± 1.2 P = .02). Maternal cardiac findings were similar between women with early vs late-onset preeclampsia. Hemodynamic parameters are significantly different between those women with mild preeclampsia who remained stable compared with those who progressed toward a severe disease. Cardiac output Z-score, systemic vascular resistance Z-score, and uterine arteries' pulsatility index Z-score showed similar sensitivity (80% vs 75% vs 80%, respectively) and specificity (73% vs. 73% vs 74%, respectively), while the association of systemic vascular resistance Z-score and uterine arteries pulsatility index Z-score showed a sensitivity of 95% and a specificity of 80% (area under the curve, 0.90) in predicting evolution toward severe forms. CONCLUSION: Evaluation of maternal cardiovascular system could help clinician in defining a subset of preeclamptic patients with more profound placental impairment and might predict the likelihood of progression toward a severe condition in cases with a mild preeclampsia at clinical onset.
引用
- Di Pasquo E, Ghi T, Dall'Asta A, et al. Maternal cardiac parameters can help in differentiating the clinical profile of preeclampsia and in predicting progression from mild to severe forms. Am J Obstet Gynecol. 2019. PMID: 31226294. doi:10.1016/j.ajog.2019.06.029
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。