超声评估盆底肌收缩:可靠性及基于超声的收缩量表开发
横断面研究纳入195名女性(压力性尿失禁手术65例、脱垂手术65例、初孕妇65例),用阴道触诊改良牛津量表(MOS)和2D/3D经会阴超声评估盆底肌收缩。2D提肛肌裂孔前后径比例变化组内ICC为0.81,组间ICC为0.82,与MOS评分相关性中等(rS=0.52),并据此构建超声收缩量表。
要点
- 2D提肛肌裂孔前后径比例变化的组内ICC为0.81(95%CI 0.74-0.85)。
- 组间ICC:2D前后径0.82、3D前后径0.80、裂孔面积0.72。
- 超声收缩量表:2D前后径比例变化<1%为无收缩,2-14%弱,15-29%正常,>30%强。
核心结论
- 超声似乎是评估盆底肌收缩的客观且可靠的方法。
- 2D提肛肌裂孔前后径比例变化的ICC最高,与阴道触诊MOS评分呈中等相关,并据此构建了超声收缩量表。
研究设计与样本
- 横断面研究,纳入195名女性,其中压力性尿失禁手术65例、脱垂手术65例、初孕妇65例。
- 盆底肌收缩通过阴道触诊改良牛津量表(MOS)及2D/3D经会阴超声评估。
- 一名评估者重复所有超声测量用于组内信度与一致性分析,三名独立评估者分析60个超声容积用于组间信度与一致性分析。
- 采用组内相关系数(ICC)评估信度,Bland-Altman分析评估一致性,断层超声识别重大提肛肌损伤,Spearman秩相关系数(rS)评估超声测量与MOS评分的相关性。
主要发现
- 2D提肛肌裂孔前后径比例变化的组内ICC为0.81(95%CI 0.74-0.85)。
- 组间ICC:2D前后径比例变化0.82(95%CI 0.72-0.89),3D前后径比例变化0.80(95%CI 0.69-0.88),裂孔面积比例变化0.72(95%CI 0.56-0.83)。
- 重大提肛肌损伤的患病率为22.6%。
- 超声测量与MOS评分的相关性:2D前后径rS=0.52,3D前后径rS=0.62,裂孔面积rS=0.47(所有P<0.001)。
关键数值与推荐
- 超声收缩量表:2D提肛肌裂孔前后径比例变化<1%对应无收缩,2-14%对应弱收缩,15-29%对应正常收缩,>30%对应强收缩。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To determine intra- and interrater reliability and agreement for ultrasound measurements of pelvic floor muscle contraction and to assess the correlation between ultrasound and vaginal palpation. We also aimed to develop an ultrasound scale for assessment of pelvic floor muscle contraction. METHODS: This was a cross-sectional study of 195 women scheduled for stress urinary incontinence (n = 65) or prolapse (n = 65) surgery or who were primigravid (n = 65). Pelvic floor muscle contraction was assessed by vaginal palpation using the Modified Oxford Scale (MOS) and by two- and three-dimensional (2D/3D) transperineal ultrasound. Proportional change in 2D and 3D levator hiatal anteroposterior (AP) diameter and 3D levator hiatal area between rest and contraction were used as measures of pelvic floor muscle contraction. One rater repeated all ultrasound measurements on stored volumes, which were used for intrarater reliability and agreement analysis, and three independent raters analyzed 60 ultrasound volumes for interrater reliability and agreement analysis. Reliability was assessed using the intraclass correlation coefficient (ICC) and agreement using Bland-Altman analysis. Tomographic ultrasound was used to identify women with major levator injury. Spearman's rank correlation coefficient (rS ) was used to assess the correlation between ultrasound measurements of pelvic floor muscle contraction and MOS score. The proportion of women allocated to each category of muscle contraction (absent, weak, moderate or strong) by palpation was used to determine the cut-offs for the ultrasound scale. RESULTS: Intrarater ICC was 0.81 (95% CI, 0.74-0.85) for proportional change in 2D levator hiatal AP diameter. Interrater ICC was 0.82 (95% CI, 0.72-0.89) for proportional change in 2D AP diameter, 0.80 (95% CI, 0.69-0.88) for proportional change in 3D AP diameter and 0.72 (95% CI, 0.56-0.83) for proportional change in hiatal area. The prevalence of major levator injury was 22.6%. The strength of correlation (rS ) between ultrasound measurements and MOS score was 0.52 for 2D AP diameter, 0.62 for 3D AP diameter and 0.47 for hiatal area (P < 0.001 for all). On the ultrasound contraction scale, proportional change in 2D levator hiatal AP diameter of < 1% corresponds to absent, 2-14% to weak, 15-29% to normal and > 30% to strong contraction. CONCLUSIONS: Ultrasound seems to be an objective and reliable method for evaluation of pelvic floor muscle contraction. Proportional change in 2D levator hiatal AP diameter had the highest ICC and moderate correlation with MOS score assessed by vaginal palpation, and we constructed an ultrasound scale for assessment of pelvic floor muscle contraction based on this measure. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.
引用
- Nyhus MØ, Oversand SH, Salvesen Ø, et al. Ultrasound assessment of pelvic floor muscle contraction: reliability and development of an ultrasound-based contraction scale. Ultrasound Obstet Gynecol. 2019. PMID: 31237722. doi:10.1002/uog.20382
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。