文献速递产科母胎医学

双胎妊娠先兆早产中单次与重复宫颈长度测量的研究

Single and repeat cervical-length measurement in twin gestation with threatened preterm labor.
PubMed 文献 · Ultrasound Obstet Gynecol · 2020-01-01

该回顾性研究纳入2012至2018年德国图宾根大学医院围产中心257例24+0至33+6周出现规律宫缩的双胎妊娠孕妇,评估单次与重复宫颈长度测量对早产的预测价值。结果显示宫颈长度与7天内分娩相关但预测能力较弱,首次与第二次测量预测7天内分娩的ROC曲线下面积无显著差异。

要点

  • 宫颈长度<10.0mm组7天内分娩率为29.0%,≥25.0mm组为0%。
  • 首次宫颈长度测量与入院至分娩间隔存在弱但显著的关联(P=0.003,r=0.184)。
  • 首次与第二次宫颈长度测量预测7天内分娩的AUC分别为0.676与0.661,无显著差异。

核心结论

  • 超声测量宫颈长度有助于预测有症状双胎妊娠孕妇就诊后7天内的早产,但预测能力相对较弱。

研究设计与样本

  • 回顾性研究,纳入2012至2018年德国图宾根大学医院围产中心257例双胎妊娠孕妇,孕周24+0至33+6周,出现疼痛性规律宫缩。
  • 入院时行经阴道超声测量宫颈长度,并在宫缩停止后数天重复测量。
  • 治疗包括使用宫缩抑制剂(通常为口服硝苯地平)不超过48小时,宫颈长度≤25mm时使用类固醇。

主要发现

  • 研究人群80.2%为双绒毛膜双羊膜囊双胎,入院时母亲年龄中位数32.0岁,孕周中位数29.9周。
  • 入院后7天内早产23例(8.9%),34周前分娩82例(31.9%),全人群宫颈长度中位数17.0mm。
  • 首次评估后7天内分娩率:宫颈长度<10.0mm组29.0%,10.0-14.9mm组10.6%,15.0-19.9mm组4.2%,20.0-24.9mm组6.3%,≥25.0mm组0%。
  • 248例在中位时间间隔3天(IQR 2-5天)后重复测量宫颈长度,中位数17.0mm(IQR 11.5-22.0mm),第二次测量后7天内分娩25/248例(10.1%)。
  • 二元回归分析显示,首次宫颈长度测量(OR 0.895,P=0.003)和第二次测量(OR 0.908,P=0.002)与第二次测量后7天内分娩显著相关,但两次测量差值(OR 0.961,P=0.361)无显著关联。

关键数值与推荐

  • 宫颈长度分组界值:<10.0mm、10.0-14.9mm、15.0-19.9mm、20.0-24.9mm、≥25.0mm。
  • 宫颈长度≤25mm时使用类固醇。
  • 宫缩抑制剂(通常为口服硝苯地平)使用不超过48小时。

临床怎么用

  • 对于有症状的双胎妊娠孕妇,超声测量宫颈长度可辅助预测就诊后7天内的早产,但预测能力相对较弱。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To examine the effectiveness of single and repeat sonographic cervical-length (CL) measurement in predicting preterm delivery in symptomatic women with a twin pregnancy. METHODS: This was a retrospective study of women with a twin gestation who presented with painful and regular uterine contractions at 24 + 0 to 33 + 6 weeks' gestation at the perinatal unit of the University Hospital of Tübingen, Tübingen, Germany between 2012 and 2018. CL was measured on transvaginal ultrasound at the time of admission and a few days later after cessation of contractions. Treatment included administration of tocolytics (usually oral nifedipine), for no more than 48 h, and administration of steroids if CL was ≤ 25 mm. Patients were clustered into five groups according to the CL measurement obtained at first assessment: < 10.0 mm; between 10.0 and 14.9 mm; between 15.0 and 19.9 mm; between 20.0 and 24.9 mm; and ≥ 25.0 mm. For each group, we calculated the test performance of CL measurement for prediction of preterm delivery within the subsequent 7 days and before 34 weeks' gestation. Regression analysis was used to evaluate the test performance of the second CL measurement for predicting preterm delivery within 7 days after the second assessment. RESULTS: The study population consisted of 257 twin pregnancies, of which 80.2% were dichorionic diamniotic. Median maternal and gestational ages at the time of admission were 32.0 years and 29.9 weeks' gestation, respectively. Preterm birth within 7 days of admission occurred in 23 (8.9%) pregnancies, and 82 (31.9%) patients delivered prior to 34 weeks' gestation. Median CL for the entire study population was 17.0 mm. Delivery within 7 days after the first assessment occurred in 29.0%, 10.6%, 4.2%, 6.3% and 0% of women with CL < 10.0 mm, 10.0-14.9 mm, 15.0-19.9 mm, 20.0-24.9 mm and ≥ 25.0 mm, respectively. There was a weak, but significant, association between the CL measurement at the time of admission and the time interval between admission and delivery (interval = 27.9 + 0.58 × CL; P = 0.003, r = 0.184). CL was measured again after a median time interval of 3 (interquartile range (IQR), 2-5) days in 248 cases. Median second CL measurement was 17.0 (IQR, 11.5-22.0) mm. Delivery occurred within the subsequent 7 days after the second measurement in 25/248 (10.1%) cases. Binary regression analysis indicated that the first (odds ratio (OR), 0.895; P = 0.003) and second (OR, 0.908; P = 0.002) CL measurements, but not the difference between the two measurements (OR, 0.961; P = 0.361), were associated significantly with delivery within 7 days after the second measurement. Receiver-operating-characteristics (ROC)-curve analysis for the prediction of delivery within 7 days after the second assessment did not show a significant difference between the predictive performance of the first (area under ROC curve (AUC), 0.676 (95% CI, 0.559-0.793)) and the second (AUC, 0.661 (95% CI, 0.531-0.790)) measurement. CONCLUSION: Sonographic measurement of CL can be helpful in predicting preterm delivery within 7 days of presentation in symptomatic women with a twin gestation; however, the test performance is relatively weak. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Prodan N, Wagner P, Sonek J, et al. Single and repeat cervical-length measurement in twin gestation with threatened preterm labor. Ultrasound Obstet Gynecol. 2020. PMID: 31066097. doi:10.1002/uog.20306

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。