经宫颈器械举宫辅助的经阴道自然腔道内镜手术子宫切除术
本文以视频逐步描述经阴道自然腔道内镜手术(vNOTES)子宫切除术中借助经宫颈器械举宫的技术。患者47岁,因月经过多4年且药物治疗失败就诊,超声提示子宫增大、可疑子宫腺肌病,体重指数27,有2次阴道分娩史及腹腔镜输卵管绝育史。举宫提供杠杆作用帮助暴露子宫各附着处并防止子宫意外旋转,手术无并发症完成,估计总失血量55 mL,患者第3天出院。
要点
- 经宫颈置入器械举宫可为vNOTES子宫切除术提供杠杆,暴露子宫各附着处。
- 举宫可防止子宫及其附件的意外旋转,并让术者第二只手用于牵拉肠管和附件。
- 因器械尖端在vNOTES中不能完全可见,举宫使子宫及附件偏离重要结构,防止器械尖端热损伤。
核心结论
- 由于器械尖端在vNOTES手术中不能完全可见,举宫有助于使子宫及其附件偏离重要结构,从而防止器械尖端造成意外热损伤。
- 作者认为这是vNOTES子宫切除术中可行且安全的技术。
研究设计与样本
- 视频形式,逐步描述技术。
- 地点为印度贾尔冈海军多专科医院微创妇科手术科。
- 患者为1例47岁女性。
主要发现
- 患者有4年月经过多史及月经过多药物治疗失败史。
- 超声显示子宫增大,表现提示子宫腺肌病。
- 患者体重指数为27,有2次正常阴道分娩史,既往行腹腔镜输卵管绝育术。
- 术中经宫颈将器械置入子宫进行举宫,提供杠杆作用,帮助获得子宫各附着处的良好暴露。
- 举宫还防止了子宫及其附件的意外旋转,术者无需用第二只手牵拉子宫,第二只手可用于牵拉肠管和附件。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
STUDY OBJECTIVE: To describe the technique of transvaginal natural orifice transluminal endoscopic surgery (vNOTES) hysterectomy with the aid of transcervical instrumental uterine manipulation. DESIGN: Video with step by step description of technique. SETTING: Minimally Invasive Gynaecological Surgery Department, Naval Multi Speciality Hospital, Jalgaon, India. PATIENT: A 47-year-old woman. INTERVENTION: vNOTES hysterectomy. MEASUREMENTS AND MAIN RESULTS: A 47-year-old patient presented with history of menorrhagia since 4 years as well as a history of failed medical management for menorrhagia. Ultrasonography showed an enlarged uterus with findings suggestive of adenomyosis. Body mass index of the patient was 27. She had a history of 2 normal vaginal deliveries and had undergone laparoscopic tubal sterilization in the past. During vNOTES hysterectomy, an instrument was placed transcervically into the uterus for manipulation, providing leverage that helped gain good exposure of all uterine attachments. It also prevented unintentional rotation of uterus and its attachments. Therefore, the surgeon did not need to use a second hand for retraction of the uterus during surgery, allowing that second hand for retraction of bowel and adnexa. Hysterectomy was completed without any complications. Total estimated blood loss was 55 mL, and the patient was discharged on the third day. CONCLUSION: Because the tip of instrument is not completely visible in vNOTES surgery, manipulation helps to deflect the uterus and its attachments away from important structures, thus preventing inadvertent thermal damage from the tip of the instrument. This is a feasible and safe technique for vNOTES hysterectomy.
引用
- Naval S, Naval R, Naval S, et al. Transvaginal Natural Orifice Transluminal Endoscopic Surgery Hysterectomy Aided by Transcervical Instrumental Uterine Manipulation. J Minim Invasive Gynecol. 2019. PMID: 31100341. doi:10.1016/j.jmig.2019.05.004
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。