文献速递母胎医学产科

平台、大小过滤阈值及靶向区域对产前诊断中染色体基因组微阵列检测拷贝数变异和单亲二体的影响:5026例妊娠的结果

Effects of platforms, size filter cutoffs, and targeted regions of cytogenomic microarray on detection of copy number variants and uniparental disomy in prenatal diagnosis: Results from 5026 pregnancies.
PubMed 文献 · Prenat Diagn · 2019-02-08

研究纳入5026例连续性产前标本(>98%为高危妊娠),用高分辨率染色体基因组微阵列检测,非靶向区域缺失阈值50 kb、重复阈值200 kb,靶向区域缺失阈值20 kb、重复阈值100 kb。当前检测率为11.2%(562/5026),其中异常发现543例、可能致病变异19例。若改用分辨率相同或更低、阈值更小或更大的平台,总体变异(排除可能良性)和单亲二体的假想检出率下降范围为3.8%至23.0%;对于<1 Mb的致病及可能致病拷贝数变异亚组,检出率下降范围为2.7%至24.3%。

要点

  • 当前高分辨率染色体基因组微阵列产前检测率为11.2%(562/5026)。
  • 改用分辨率更低或阈值不同的平台,总体变异和单亲二体检出率假想下降3.8%至23.0%。
  • <1 Mb的致病及可能致病拷贝数变异检出率假想下降2.7%至24.3%。

核心结论

  • 所选染色体基因组微阵列平台、数据分析所用大小过滤阈值及靶向区域对产前病例队列中拷贝数变异和单亲二体的检出有显著影响。

研究设计与样本

  • 研究纳入5026例连续性产前标本(>98%为高危妊娠),采用高分辨率染色体基因组微阵列检测。
  • 非靶向区域阈值设为缺失50 kb、重复200 kb,靶向区域阈值设为缺失20 kb、重复100 kb。
  • 评估当前检测方法的实际检出率,并评估使用分辨率相同或更低、阈值更小或更大的平台时的假想检出率。

主要发现

  • 当前检测方法的检出率为11.2%(562/5026),包括异常发现543例和可能致病变异19例。
  • 假想总体变异(排除可能良性)和单亲二体检出率下降范围为3.8%至23.0%。
  • 对于<1 Mb的致病及可能致病拷贝数变异亚组,检出率下降范围为2.7%至24.3%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: We evaluated the effects of platforms, size filter cutoffs, and targeted regions of cytogenomic microarray (CMA) on the detection of copy number variants (CNVs) and uniparental disomy (UPD) in prenatal diagnosis. METHODS: Five thousand twenty-six consecutive prenatal specimens (>98% high-risk pregnancy) were studied by high-resolution CMA, with cutoffs of 50 kb for losses and 200 kb for gains in nontargeted regions and 20 kb for losses and 100 kb for gains in targeted regions. We assessed actual detection rates using the current assay as well as hypothetical detection rates using platforms with the same or lower resolution and smaller or larger cutoffs. RESULTS: The detection rate of our current assay was 11.2% (562 of 5026), including abnormal findings in 543 cases and likely pathogenic variants in 19. The hypothetical decrease in the overall detection of variants (excluding likely benign) and UPD ranged from 3.8% to 23.0%. For the subgroup of pathogenic and likely pathogenic CNVs < 1 Mb, the decrease of detection ranged from 2.7% to 24.3%. CONCLUSIONS: These findings underscore the significant effects of chosen CMA platform, as well as size filter cutoffs and targeted regions used in data analysis, on detection of CNVs and UPDs in a cohort of prenatal cases.

来源:Prenat Diagn,查看原文。版权归原作者所有。

引用

  1. Wang JC, Radcliff J, Coe SJ, et al. Effects of platforms, size filter cutoffs, and targeted regions of cytogenomic microarray on detection of copy number variants and uniparental disomy in prenatal diagnosis: Results from 5026 pregnancies. Prenat Diagn. 2019. PMID: 30734327. doi:10.1002/pd.5375

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。