文献速递妇科

二维与三维经阴道超声诊断内肌层子宫腺肌病的比较

Two- and three-dimensional transvaginal ultrasonography for diagnosis of adenomyosis of the inner myometrium.
PubMed 文献 · Reprod Biomed Online · 2018-12-26

研究连续纳入110例因异常子宫出血拟行子宫切除或子宫内膜肌层切除的绝经前女性,比较二维与三维经阴道超声诊断内肌层子宫腺肌病的准确性,以组织病理为金标准。内肌层子宫腺肌病患病率为29%。三维与二维超声准确度相似,三维特异性未达统计学显著优势(P=0.06)。

要点

  • 二维经阴道超声灵敏度72%(95%CI 53-86),特异度76%(95%CI 65-85),AUC 0.74(95%CI 0.7-0.8)。
  • 三维经阴道超声灵敏度69%(95%CI 50-84),特异度86%(95%CI 76-93),AUC 0.77(95%CI 0.7-0.9)。
  • 三维最准确特征为结合带不规则(JZmax-JZmin≥5mm)(AUC 0.78)。

核心结论

  • 三维经阴道超声诊断内肌层子宫腺肌病的准确度与二维经阴道超声相似,均较高。
  • 三维经阴道超声识别结合带不规则可能有助于诊断。
  • 两个或以上二维特征与两个或以上三维特征联合可能提供更客观的诊断,可能有助于临床实践和未来研究。

研究设计与样本

  • 连续纳入110例因异常子宫出血拟行子宫切除或子宫内膜肌层切除的绝经前女性。
  • 所有参与者均行实时二维经阴道超声,随后盲法离线行三维经阴道超声诊断子宫腺肌病。
  • 以内肌层详细组织病理学检查为金标准进行比较。

主要发现

  • 内肌层子宫腺肌病患病率为29%。
  • 二维经阴道超声灵敏度72%(95%CI 53-86),三维经阴道超声灵敏度69%(95%CI 50-84)。
  • 二维经阴道超声特异度76%(95%CI 65-85),三维经阴道超声特异度86%(95%CI 76-93)。
  • 二维经阴道超声AUC 0.74(95%CI 0.7-0.8),三维经阴道超声AUC 0.77(95%CI 0.7-0.9)。
  • 三维经阴道超声特异度未达统计学显著优于二维经阴道超声,两者差异接近统计学显著(P=0.06)。

关键数值与推荐

  • 三维最准确特征为结合带不规则(JZmax-JZmin≥5mm),AUC 0.78。
  • 两个或以上二维特征与两个或以上三维特征联合的AUC为0.77。

临床怎么用

  • 三维经阴道超声诊断内肌层子宫腺肌病的准确度与二维经阴道超声相似,均可用于诊断。
  • 三维经阴道超声识别结合带不规则可能有助于诊断。
  • 两个或以上二维特征与两个或以上三维特征联合可能提供更客观的诊断,可能有助于临床实践和未来研究。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

RESEARCH QUESTION: How diagnostically accurate is two-dimensional (2D-TVS) compared with three-dimensional transvaginal ultrasonography (3D-TVS) in diagnosing adenomyosis of the inner myometrium. What is the most accurate combination of ultrasonographic features? DESIGN: Premenopausal women (n = 110) scheduled for hysterectomy or transcervical resection of the endomyometrium owing to abnormal uterine bleeding were consecutively enrolled. All participants had real-time 2D-TVS and, later, blinded off-line 3D-TVS to diagnose adenomyosis. Results were compared with a detailed histopathological examination of the inner myometrium as gold standard. RESULTS: Prevalence of adenomyosis of the inner myometrium was 29%. For 2D-TVS and 3D-TVS, respectively, the diagnostic accuracy was sensitivity 72% (95% CI 53 to 86) and 69% (95% CI 50 to 84); specificity 76% (95% CI 65 to 85) and 86% (95% CI 76-93); and area under the curve (AUC) 0.74 (95% CI 0.7 to 0.8) and 0.77 (95% CI 0.7 to 0.9). Specificity of 3D-TVS was not statistically significantly better than 2D-TVS; the difference between them almost reached statistical significance (P = 0.06). The most accurate three-dimensional feature was junctional zone irregularity (JZmax-JZmin ≥5mm) (AUC: 0.78). A combination of two or more two-dimensional and two or more three-dimensional features was highly accurate (AUC: 0.77). CONCLUSIONS: For diagnosing adenomyosis of the inner myometrium, 3D-TVS offers a high accuracy similar to 2D-TVS. Identification of junctional zone irregularity with 3D-TVS may be beneficial to diagnosis. Two or more two-dimensional features and two or more three-dimensional features combined may give a more objective diagnosis, and may be useful for clinical practice and future research.

来源:Reprod Biomed Online,查看原文。版权归原作者所有。

引用

  1. Rasmussen CK, Hansen ES, Ernst E, et al. Two- and three-dimensional transvaginal ultrasonography for diagnosis of adenomyosis of the inner myometrium. Reprod Biomed Online. 2018. PMID: 30792048. doi:10.1016/j.rbmo.2018.12.033

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。