文献速递产科母胎医学

全国性胎儿畸形筛查规划的实施改善主要心脏缺陷的产前检出:一项11年全国人群队列研究

The implementation of a nationwide anomaly screening programme improves prenatal detection of major cardiac defects: an 11-year national population-based cohort study.
PubMed 文献 · BJOG · 2019-01-25

结果显示UVH产前检出率从50.4%升至82.8%,TGA从12.3%升至41.0%(P<0.0001),母亲肥胖等危险因素未影响检出率,但地区间差异明显。

要点

  • 全国筛查实施后UVH产前检出率由50.4%升至82.8%,TGA由12.3%升至41.0%(P<0.0001)。
  • 母亲肥胖、体外受精、孕前糖尿病和吸烟未影响产前检出率。
  • 检出率地区间存在明显差异,实施筛查规划需建立结构化指南,并推荐前瞻性筛查登记。

核心结论

  • 全国性筛查规划改善了UVH和TGA的总体产前检出率,但观察到地区差异。
  • 肥胖或其他母亲危险因素未影响筛查规划效能。
  • 实施筛查规划时建立结构化指南和推荐至关重要;此外强烈推荐建立前瞻性筛查登记以确保筛查高质量。

研究设计与样本

  • 共纳入642456名产妇和3449例因严重胎儿畸形终止妊娠者。
  • 在筛查前、过渡期和筛查期三个时间段计算产前检出率,并评估母亲危险因素(肥胖、体外受精、孕前糖尿病和吸烟)的影响。

主要发现

  • 共检出483例UVH和184例TGA。
  • UVH产前检出率从50.4%升至82.8%,TGA从12.3%升至41.0%(P<0.0001)。
  • 母亲危险因素未影响产前检出率,但检出率按地区差异显著。

临床怎么用

  • 作者认为实施筛查规划时建立结构化指南和推荐至关重要。
  • 作者强烈推荐建立前瞻性筛查登记以确保筛查高质量。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To evaluate whether a nationwide prenatal anomaly screening programme improves detection rates of univentricular heart (UVH) and transposition of great arteries (TGA), and whether maternal risk factors for severe fetal heart disease affect prenatal detection. DESIGN: Population-based cohort study. SETTING: Nationwide data from Finnish registries 2004-14. POPULATION: A total of 642 456 parturients and 3449 terminated pregnancies due to severe fetal anomaly. METHODS: Prenatal detection rates were calculated in three time periods (prescreening, transition and screening phase). The effect of maternal risk factors (obesity, in vitro fertilisation, pregestational diabetes and smoking) was evaluated. MAIN OUTCOME MEASURES: Change in detection rates and impact of maternal risk factors on screening programme efficacy. RESULTS: In total, 483 cases of UVH and 184 of TGA were detected. The prenatal detection rate of UVH increased from 50.4% to 82.8% and of TGA from 12.3% to 41.0% (P < 0.0001). Maternal risk factors did not affect prenatal detection rate, but detection rate differed substantially by region. CONCLUSIONS: A nationwide screening programme improved overall UVH and TGA detection rates, but regional differences were observed. Obesity or other maternal risk factors did not affect the screening programme efficacy. The establishment of structured guidelines and recommendations is essential when implementing the screening programme. In addition, a prospective screening register is highly recommended to ensure high quality of screening. TWEETABLE ABSTRACT: Implementation of a nationwide prenatal anomaly screening improved detection rates of UVH and TGA.

来源:BJOG,查看原文。版权归原作者所有。

引用

  1. Hautala J, Gissler M, Ritvanen A, et al. The implementation of a nationwide anomaly screening programme improves prenatal detection of major cardiac defects: an 11-year national population-based cohort study. BJOG. 2019. PMID: 30576052. doi:10.1111/1471-0528.15589

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。