文献速递妇科生殖医学

肛门生殖器距离作为多囊卵巢综合征诊断工具的评估

Assessment of anogenital distance as a diagnostic tool in polycystic ovary syndrome.
PubMed 文献 · Reprod Biomed Online · 2018-10-06

病例对照研究纳入126例多囊卵巢综合征(PCOS)患者和159例对照,测量阴蒂前表面至肛门上缘距离(AGDAC)和后阴唇连合至肛门上缘距离(AGDAF)。AGDAC与PCOS及其各表型相关,预测全部PCOS的曲线下面积最高为0.62(95%CI 0.55-0.71),灵敏度50.0%、特异度73.0%。结论认为AGDAC可中等程度区分PCOS,可能是有用的临床工具。

要点

  • AGDAC与PCOS及其所有表型相关(P值<0.001至0.048)。
  • AGDAC预测全部PCOS的AUC为0.62(95%CI 0.55-0.71),灵敏度50.0%,特异度73.0%。
  • AGDAF与PCOS无关联。

核心结论

  • AGDAC可中等程度区分PCOS的存在,可能是有用的临床工具。

研究设计与样本

  • 病例对照研究,于2014年9月至2016年5月在西班牙东南部穆尔西亚地区大学临床医院妇产科进行,纳入126例PCOS病例和159例无PCOS对照。

主要发现

  • AGDAC与PCOS及其所有表型相关(P值<0.001至0.048),AGDAF与PCOS无关联。
  • AGDAC预测全部PCOS的曲线下面积最高为0.62(95%CI 0.55-0.71),灵敏度50.0%、特异度73.0%,阳性预测值59.0%、阴性预测值64.4%。

关键数值与推荐

  • AGDAC预测全部PCOS的AUC为0.62(95%CI 0.55-0.71),灵敏度50.0%,特异度73.0%,阳性预测值59.0%,阴性预测值64.4%。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

RESEARCH QUESTION: Is anogenital distance (AGD) a useful clinical tool for predicting polycystic ovarian syndrome (PCOS) and its main National Institutes of Health (NIH) phenotypes? DESIGN: Case-control study conducted between September 2014 and May 2016 at the Department of Obstetrics and Gynecology of the University Clinical Hospital 'Virgen de la Arrixaca' in the Murcia region (south-eastern Spain). One hundred and twenty-six cases of PCOS and 159 controls without PCOS were included. AGD measurements were taken from the anterior clitoral surface to the upper verge of the anus (AGDAC), and from the posterior fourchette to the upper verge of the anus (AGDAF). Parametric and non-parametric tests and receiver operating characteristic (ROC) curves were used to assess associations between AGD and the presence of PCOS and its phenotypes. RESULTS: AGDAC, but not AGDAF, was associated with PCOS and all its phenotypes (P-values < 0.001 to 0.048). The highest area under the curve (0.62; 95% confidence interval 0.55 to 0.71) was obtained for all PCOS with AGDAC with a sensitivity and specificity of 50.0% and 73.0%, and positive and negative predictive value of 59.0% and 64.4%, respectively. CONCLUSIONS: AGDAC could moderately discriminate the presence of PCOS and may be a useful clinical tool.

来源:Reprod Biomed Online,查看原文。版权归原作者所有。

引用

  1. Hernández-Peñalver AI, Sánchez-Ferrer ML, Mendiola J, et al. Assessment of anogenital distance as a diagnostic tool in polycystic ovary syndrome. Reprod Biomed Online. 2018. PMID: 30361047. doi:10.1016/j.rbmo.2018.08.020

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。