文献速递产科母胎医学

比较Hadlock胎儿生长标准与尤妮斯·肯尼迪·施莱弗国家儿童健康与人类发展研究所种族/民族标准对新生儿疾病及小于胎龄儿的预测

Comparing the Hadlock fetal growth standard to the Eunice Kennedy Shriver National Institute of Child Health and Human Development racial/ethnic standard for the prediction of neonatal morbidity and small for gestational age.
PubMed 文献 · Am J Obstet Gynecol · 2018-08-14

本回顾性诊断准确性研究纳入2013年1月1日至2017年3月31日新墨西哥大学医院1514例单胎妊娠,比较Hadlock标准与NICHD种族/民族特异性标准预测新生儿疾病和小于胎龄儿的能力。Hadlock标准在预测复合及严重复合新生儿疾病方面曲线下面积更高(均P<.001),预测小于胎龄儿的敏感性更高(61.1% vs 36.2%,P<.01),超声与出生体重百分位差异更小(6.1 vs 16.5百分位点,P<.01)。

要点

  • Hadlock标准预测新生儿疾病的曲线下面积高于NICHD标准(P<.001),但两者区分能力均不佳(曲线下面积均<0.8)。
  • Hadlock预测小于胎龄儿的敏感性为61.1%,高于NICHD插值法36.2%和整周第10百分位法46.7%(均P<.01)。
  • Hadlock的超声与出生体重百分位差异为6.1,低于NICHD的16.5百分位点(P<.01)。

核心结论

  • 尽管Hadlock标准已发表超过25年,其在预测新生儿疾病和小于胎龄儿方面均优于NICHD种族/民族特异性标准。

研究设计与样本

  • 回顾性诊断准确性研究,纳入2013年1月1日至2017年3月31日新墨西哥大学医院分娩的单胎、孕周明确、胎儿无畸形且估计胎儿体重在分娩前30天内的孕妇,共1514例。

主要发现

  • 预测复合及严重复合新生儿疾病时,Hadlock法的曲线下面积高于NICHD法(均P<.001),但两者区分能力均不佳(曲线下面积均<0.8)。
  • 预测小于胎龄儿时,Hadlock法的敏感性为61.1%,高于NICHD插值法的36.2%(P<.01)和NICHD整周第10百分位法的46.7%(P<.01)。
  • Hadlock法预测小于胎龄儿的曲线下面积为0.89,高于NICHD插值法的0.88(P<.01)。
  • Hadlock法的超声与出生体重百分位差异为6.1,低于NICHD法的16.5百分位点(P<.01)。
  • 被Hadlock法归类为生长受限但未被NICHD法归类的胎儿,其复合疾病发生率显著高于正常生长胎儿。

关键数值与推荐

  • 小于胎龄儿定义为出生体重低于第10百分位,发生率为13.6%(n=206)。
  • 预测复合及严重复合新生儿疾病时,Hadlock法曲线下面积高于NICHD法(均P<.001)。
  • 预测小于胎龄儿时,Hadlock法敏感性61.1%,NICHD插值法36.2%(P<.01),NICHD整周第10百分位法46.7%(P<.01)。
  • 预测小于胎龄儿曲线下面积Hadlock法0.89 vs NICHD插值法0.88(P<.01)。
  • 超声与出生体重百分位差异Hadlock法6.1 vs NICHD法16.5百分位点(P<.01)。

临床怎么用

  • 在美洲原住民女性中,Hadlock法预测复合及严重复合疾病的曲线下面积最高,而Hadlock法与所有NICHD种族/民族特异性方法预测小于胎龄儿的性能相当。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The fetal growth standard in widest use was published by Hadlock >25 years ago and was derived from a small, homogeneous cohort. In 2015, The Eunice Kennedy Shriver National Institute of Child Health and Human Development Fetal Growth Study published updated standards that are specific to race/ethnicity. These do not allow for precise estimated fetal weight percentile calculation, however, and their effectiveness to predict neonatal morbidity and small for gestational age has not yet been compared to the long-standing Hadlock standard. OBJECTIVE: We compared the ability of the Hadlock standard to predict neonatal morbidity and small for gestational age at birth with that of The Eunice Kennedy Shriver National Institute of Child Health and Human Development race-/ethnicity-specific standard. Our secondary objective was to compare their performance among our Native American population, which is not accounted for in the Eunice Kennedy Shriver National Institute of Child Health and Human Development standard. STUDY DESIGN: For this retrospective study of diagnostic accuracy, we reviewed deliveries at the University of New Mexico Hospital from Jan. 1, 2013, through March 31, 2017. We included mothers with singleton, well-dated pregnancies and nonanomalous fetuses with an estimated fetal weight within 30 days of delivery. Cubic spline interpolation was performed on the Eunice Kennedy Shriver National Institute of Child Health and Human Development estimated fetal weight-percentile tables to calculate percentiles specific to the gestational day. Estimated fetal weight percentiles were then calculated using both the Hadlock and Eunice Kennedy Shriver National Institute of Child Health and Human Development race-/ethnicity-specific standards according to maternal self-identified race/ethnicity. We calculated the receiver operator area under the curve of each method to predict composite and severe composite neonatal morbidity and small for gestational age at birth (birthweight <10th percentile). As an additional measure of method accuracy, we calculated the mean ultrasound-birthweight percentile discrepancy. For Native Americans, percentiles were calculated using the Hadlock and Eunice Kennedy Shriver National Institute of Child Health and Human Development race/ethnicity standards (white, black, Hispanic, Asian), and test characteristics were calculated for each to predict neonatal morbidity and small for gestational age. RESULTS: We included 1514 women, with a mean ultrasonography-to-delivery interval of 14.4 days (±8.8) and a small for gestational age rate of 13.6% (n = 206). For the prediction of both composite and severe composite neonatal morbidity, the Hadlock method had superior performance, with higher areas under the curve than the Eunice Kennedy Shriver National Institute of Child Health and Human Development method (P < .001 for both), though neither had good discriminatory value (all areas under the curve <0.8). For the prediction of small for gestational age at birth, the Hadlock standard had higher sensitivity (61.1%) than the Eunice Kennedy Shriver National Institute of Child Health and Human Development standard, both when using the interpolated Eunice Kennedy Shriver National Institute of Child Health and Human Development method (36.2%, P < .01) and the Eunice Kennedy Shriver National Institute of Child Health and Human Development whole-week 10th percentile cutoff (46.7%, P < .01). The Hadlock method also had a higher area under the curve than the Eunice Kennedy Shriver National Institute of Child Health and Human Development interpolated method to predict small for gestational age (0.89 vs 0.88, P < .01). The Hadlock method had a lower ultrasound-birthweight percentile discrepancy than the Eunice Kennedy Shriver National Institute of Child Health and Human Development method (6.1 vs 16.5 percentile points, P < .01). Fetuses classified as growth restricted by Hadlock but not Eunice Kennedy Shriver National Institute of Child Health and Human Development had significantly higher composite morbidity than normally grown fetuses. Among Native American women, the Hadlock method had the highest area under the curve to predict composite and severe composite morbidity, while the Hadlock and all Eunice Kennedy Shriver National Institute of Child Health and Human Development race-/ethnicity-specific methods performed comparably to predict small for gestational age. CONCLUSION: Despite its publication >25 years ago, the Hadlock standard is superior to the Eunice Kennedy Shriver National Institute of Child Health and Human Development race-/ethnicity-specific standard for the prediction of both neonatal morbidity and small for gestational age.

来源:Am J Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Blue NR, Beddow ME, Savabi M, et al. Comparing the Hadlock fetal growth standard to the Eunice Kennedy Shriver National Institute of Child Health and Human Development racial/ethnic standard for the prediction of neonatal morbidity and small for gestational age. Am J Obstet Gynecol. 2018. PMID: 30118689. doi:10.1016/j.ajog.2018.08.011