机器人辅助腹腔镜盆腔 floor 手术后的网片暴露:一项前瞻性队列研究
这项前瞻性观察队列研究在两家大型教学医院纳入192例症状性盆腔器官脱垂(POP)且简化POP量化分期(S-POP)≥2期的患者,行机器人辅助腹腔镜骶骨固定术或机器人辅助腹腔镜骶骨宫颈固定术。166例(86.5%)接受随访检查,中位随访15.7个月(范围8.2-44.4个月),检出2例(1.2%)阴道网片暴露,均在门诊处理。
要点
- 192例POP患者行机器人辅助腹腔镜盆腔 floor 手术,166例(86.5%)完成随访检查。
- 中位随访15.7个月(范围8.2-44.4个月),检出2例(1.2%)阴道网片暴露,均在门诊处理。
- 1例无症状缝线暴露在门诊取出;作者认为机器人辅助腹部盆腔 floor 手术网片暴露率低。
核心结论
- 作者认为,本研究中机器人辅助腹部盆腔 floor 手术治疗POP的网片暴露率低。
- 作者指出,基于当前文献,经腹部网片手术的网片相关并发症似乎低于经阴道网片手术。
研究设计与样本
- 前瞻性观察队列研究(加拿大任务 force 分类II-2)。
- 在两家具有盆腔 floor 疾病三级转诊功能的大型教学医院开展。
- 纳入症状性POP且S-POP分期≥2期患者,排除有网片修补史或同期放置无张力阴道吊带者。
- 干预为机器人辅助腹腔镜骶骨固定术或机器人辅助腹腔镜骶骨宫颈固定术。
- 192例纳入,166例(86.5%)接受随访检查;中位随访15.7个月(范围8.2-44.4个月)。
主要发现
- 随访检查采用透明窥器行盲法阴道检查,网片暴露按国际妇科泌尿协会/国际控尿学会分类系统描述。
- 检出2例(1.2%)阴道网片暴露,均在门诊治疗。
- 1例无主诉患者发现缝线暴露,在门诊取出。
临床怎么用
- 作者认为,基于当前文献,经腹部网片手术的网片相关并发症似乎低于经阴道网片手术。
- 作者在本研究中观察到机器人辅助腹部盆腔 floor 手术治疗POP的网片暴露率低。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
STUDY OBJECTIVE: To prospectively evaluate the mesh exposure rate after robot-assisted laparoscopic pelvic floor surgery for the treatment of female pelvic organ prolapse (POP) in a large cohort. DESIGN: Prospective observational cohort study (Canadian Task Force classification II-2). SETTING: Two large teaching hospitals with a tertiary referral function for pelvic floor disorders. PATIENTS: Patients with symptomatic POP and simplified POP quantification (S-POP) stage ≥2. Patients with a history of mesh repair or concomitant insertion of a tension-free vaginal tape were excluded. INTERVENTIONS: Robot-assisted laparoscopic sacrocolpopexy or robot-assisted laparoscopic supracervical hysterectomy with a sacrocervicopexy. MEASUREMENTS AND MAIN RESULTS: A blinded vaginal examination with the aid of a transparent speculum was performed to look for mesh-related complications. Mesh exposures were described following the International Urogynecological Association/International Continence Society classification system. One hundred and ninety-two patients were included, of whom 166 (86.5%) were seen for follow-up examination. The median duration of follow-up was 15.7 months (range, 8.2-44.4 months). Two vaginal mesh exposures (1.2%) were detected, both of which were treated in the outpatient clinic. One patient without any complaints had a suture exposure, which was removed in the outpatient clinic. CONCLUSION: The safety of the use of mesh in pelvic floor surgery is a matter of debate owing to the occurrence of mesh-related complications. Based on the current literature, mesh-related complications seem to be lower in transabdominal mesh surgery than in transvaginal mesh surgery. In this study, a low mesh exposure rate was observed in robot-assisted abdominal pelvic floor surgery for POP.
引用
- van Zanten F, van Iersel JJ, Hartog FE, et al. Mesh Exposure After Robot-Assisted Laparoscopic Pelvic Floor Surgery: A Prospective Cohort Study. J Minim Invasive Gynecol. 2018. PMID: 29964179. doi:10.1016/j.jmig.2018.06.015