母源细胞污染对侵入性产前分子遗传学检测的干扰效应
该研究通过混合实验模拟1%至40%的母源细胞污染,确定Sanger测序、多重连接依赖探针扩增(MLPA)和焦磷酸测序对母源细胞污染的灵敏度。Sanger测序的灵敏度范围为5%至30%,MLPA在污染≥40%时导致诊断不确定性,焦磷酸测序可检测低至1%的污染。
要点
- Sanger测序对母源细胞污染的灵敏度范围为5%至30%。
- MLPA在母源细胞污染≥40%时导致诊断不确定性。
- 焦磷酸测序对母源细胞污染非常敏感,可检测低至1%的污染。
核心结论
- Sanger测序对母源细胞污染的灵敏度可变,MLPA仅在高水平污染时才有显著影响。
- 下一代测序方法对低水平母源细胞污染敏感,但平行确定污染水平并准确定量等位基因比例有助于解释诊断结果。
- 了解显著的母源细胞污染水平有助于在样本非纯胎儿来源时做出正确产前诊断,并在许多情况下避免重复采样。
研究设计与样本
- 通过混合实验模拟1%、5%、10%、20%、30%和40%的母源细胞污染,确定Sanger DNA测序、MLPA和焦磷酸测序的显著污染水平。
主要发现
- Sanger测序对母源细胞污染的灵敏度限为5%至30%。
- MLPA在母源细胞污染≥40%时导致诊断不确定性。
- 焦磷酸测序可检测低至1%的母源细胞污染。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Fetal samples obtained by invasive techniques are prone to maternal cell contamination (MCC), which may lead to false genotyping results. Our aim was to determine 3 molecular genetic tests' sensitivity to MCC. METHOD: By mixing experiments, 1%, 5%, 10%, 20%, 30%, and 40% MCC was simulated, and significant MCC levels were determined for Sanger DNA sequencing, multiplex ligation-dependent probe amplification (MLPA), and pyrosequencing, a next-generation sequencing method. RESULTS: For Sanger sequencing, the limit of sensitivity to MCC was 5% to 30%. For MLPA, a higher proportion of MCC (≥40%) was shown to lead to diagnostic uncertainty. In contrast, pyrosequencing proved to be very sensitive to MCC, detecting a proportion as low as 1%. CONCLUSION: In the case of Sanger sequencing, sensitivity to MCC was variable, while for MLPA, only high levels of MCC proved to be significant. Although the next-generation sequencing method was sensitive to low-level MCC, if MCC level is determined in parallel, accurate quantification of allelic ratios can help to interpret the diagnostic results. Knowledge of significant MCC levels allows correct prenatal diagnosis even if samples are not purely of fetal origin and repeated sampling can be avoided in many of the cases.
引用
- Koczok K, Gombos É, Madar L, et al. Interfering effect of maternal cell contamination on invasive prenatal molecular genetic testing. Prenat Diagn. 2018. PMID: 29935118. doi:10.1002/pd.5319
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。