文献速递生殖医学

囊胚腔液核型与滋养外胚层及内细胞团的符合率低

Karyotype of the blastocoel fluid demonstrates low concordance with both trophectoderm and inner cell mass.
PubMed 文献 · Fertil Steril · 2018-01-01

本研究前瞻性比较同一囊胚的囊胚腔液(BF)、内细胞团(ICM)和滋养外胚层(TE)的基因组图谱。16枚冻存囊胚中,BF-DNA核型与TE或ICM完全一致的仅40.0%,而TE与ICM之间一致率为85.7%;BF-DNA嵌合非整倍体负荷更高。结论认为BF不能充分代表胚胎其余部分的状态,TE活检仍是预测胚胎核型最有效的方法,目前不建议将BF作为植入前遗传学筛查的唯一DNA来源。

要点

  • BF-DNA核型与TE或ICM完全一致的仅40.0%,TE与ICM一致率为85.7%。
  • BF中受累染色体总数显著高于TE和ICM,且BF-DNA嵌合非整倍体负荷更高。
  • 作者认为BF不能充分代表胚胎其余部分状态,目前不建议将BF作为植入前遗传学筛查的唯一DNA来源。

核心结论

  • BF-DNA可成功扩增并进行NGS,但因与ICM和TE符合率低,BF不能充分代表胚胎其余部分的状态。
  • 为克服BF采样与处理的生物学和技术挑战,囊胚穿刺需改进实验室方案和非整倍体判定算法。
  • TE活检仍是预测胚胎核型最有效的方法,目前不建议将BF作为植入前遗传学筛查的唯一DNA来源。

研究设计与样本

  • 前瞻性研究,比较同一囊胚的BF、ICM和TE细胞的基因组图谱。
  • 研究在学术机构和体外受精单位进行,纳入16枚捐赠的囊胚期冻存胚胎。
  • 从每枚囊胚中获取BF、TE和ICM细胞,采用下一代测序(NGS)进行染色体分析。

主要发现

  • 16枚囊胚中,10份BF样本和14份TE及ICM样本提供了可用于全面染色体分析的可靠NGS数据。
  • BF-DNA核型与TE或ICM完全一致的仅40.0%,而TE与ICM之间一致率为85.7%。
  • BF-DNA存在嵌合非整倍体,且BF中受累染色体总数显著高于TE和ICM。

临床怎么用

  • 作者认为,TE活检仍是预测胚胎核型最有效的方法。
  • 作者认为,目前不建议将BF作为植入前遗传学筛查的唯一DNA来源。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To compare the genomic profiles of blastocoel fluid (BF), inner cell mass (ICM), and trophectoderm (TE) cells derived from the same blastocyst. DESIGN: Prospective study. SETTING: Academic and in vitro fertilization units. PATIENT(S): Sixteen donated cryopreserved embryos at blastocyst stage. INTERVENTION(S): BF, TE, and ICM cells were retrieved from each blastocyst for chromosome analysis by means of next-generation sequencing (NGS). MAIN OUTCOME MEASURE(S): Aneuploidy screening and assessment of mosaicism in BF, TE and ICM samples with subsequent comparison of genomic profiles between the three blastocyst compartments. RESULT(S): Out of 16 blastocysts, 10 BF samples and 14 TE and ICM samples provided reliable NGS data for comprehensive chromosome analysis. Only 40.0% of BF-DNA karyotypes were fully concordant with TE or ICM, compared with 85.7% concordance between TE and ICM. In addition, BF-DNA was burdened with mosaic aneuploidies and the total number of affected chromosomes in BF was significantly higher compared with the TE and ICM. CONCLUSION(S): BF-DNA can be successfully amplified and subjected to NGS, but owing to increased discordance with ICM and TE, BF does not adequately represent the status of the rest of the embryo. To overcome biologic and technical challenges associated with BF sampling and processing, blastocentesis would require improvement in both laboratory protocols and aneuploidy calling algorithms. Therefore, TE biopsy remains the most effective way to predict embryonic karyotype, and the use of BF as a single source of DNA for preimplantation genetic screening is not yet advised.

来源:Fertil Steril,查看原文。版权归原作者所有。

引用

  1. Tšuiko O, Zhigalina DI, Jatsenko T, et al. Karyotype of the blastocoel fluid demonstrates low concordance with both trophectoderm and inner cell mass. Fertil Steril. 2018. PMID: 29935648. doi:10.1016/j.fertnstert.2018.02.008

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。