文献速递产科母胎医学

早孕期子痫前期联合筛查中子宫动脉多普勒测量质量评估

Quality assessment of uterine artery Doppler measurement in first-trimester combined screening for pre-eclampsia.
PubMed 文献 · Ultrasound Obstet Gynecol · 2019-01-11

在澳大利亚悉尼一家大型诊所,对2014年5月至2017年2月连续早孕期筛查的子痫前期联合筛查病例,评估46名超声医师测量平均子宫动脉搏动指数的质量。总体中位UtA-PI MoM为1.042,41名(97.6%)测量超过50次的医师中多数处于可接受范围;测量偏低或偏高组筛查阳性率分别为7.2%和13.2%,与11.2%相比差异有统计学意义(P < 0.001)。结论认为遵循既定方案时训练有素的医师测量良好,但系统误差影响筛查阳性率,应建立质量控制并可能需要再培训。

要点

  • 46名超声医师中42名(91.3%)完成超过50次检查,其中41名(97.6%)的UtA-PI处于可接受范围。
  • 平均UtA-PI MoM低于0.95组筛查阳性率7.2%,高于1.05组13.2%,均与0.95-1.05组的11.2%有显著差异(P < 0.001)。
  • 遵循既定方案时训练有素的医师测量良好,但系统误差影响筛查阳性率,应建立质量控制并可能需要再培训。

核心结论

  • 遵循既定方案时,训练有素的医师对子宫动脉多普勒测量良好;轻微变异在预期之内,但测量的系统误差会影响筛查阳性率,因此应建立质量控制流程并可能需要再培训工作人员。

研究设计与样本

  • 在澳大利亚悉尼一家大型诊所,2014年5月至2017年2月连续纳入单胎妊娠并接受早孕期胎儿染色体异常筛查的妇女,同时基于胎儿医学基金会(FMF)算法进行子痫前期联合筛查,共21 010名妇女。

主要发现

  • 总体中位UtA-PI MoM为1.042(四分位距0.85-1.26)。
  • 46名超声医师中42名(91.3%)完成超过50次检查,其中41名(97.6%)测量的UtA-PI处于可接受范围。
  • 平均UtA-PI MoM低于0.95的医师筛查阳性率为7.2%,高于1.05的医师为13.2%,均与测量在0.95-1.05间的医师的11.2%相比差异有统计学意义(P < 0.001)。

关键数值与推荐

  • 平均UtA-PI MoM在0.95至1.05之间被视为理想,在0.90至1.10之间被视为可接受。
  • 按医师平均log10 UtA-PI MoM分组计算早产子痫前期筛查阳性率,并用卡方检验比较。

临床怎么用

  • 作者认为应建立质量控制流程,并可能需要再培训工作人员。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To assess the quality of mean uterine artery (UtA) pulsatility index (PI) measurement in a first-trimester pre-eclampsia screening program. METHODS: Consecutive women with a singleton pregnancy attending first-trimester screening for fetal chromosomal abnormalities also had combined screening for pre-eclampsia based on the Fetal Medicine Foundation (FMF) algorithm, at a large practice in Sydney, Australia, from May 2014 to February 2017. Distributions of mean UtA-PI multiples of the median (MoM) on a logarithmic scale were plotted in relation to the normal median with 95% CI for each operator and for each month. Central tendency and dispersion and cumulative sum charts were produced. Mean UtA-PI MoM values between 0.95 and 1.05 were considered ideal and those between 0.90 and 1.10 were considered acceptable. The screen-positive rates for preterm pre-eclampsia in different groups of sonographers according to their mean log10 UtA-PI MoM were calculated and compared using the chi-square test. RESULTS: A total of 21 010 women attended for first-trimester ultrasound and had screening for pre-eclampsia. The overall median UtA-PI MoM was 1.042 (interquartile range (IQR), 0.85-1.26). Of 46 sonographers, 42 (91.3%) performed more than 50 examinations and, of those, 41 (97.6%) measured UtA-PI within the acceptable range. Sonographers measuring UtA-PI MoM on average below 0.95 and those measuring it above 1.05 had, respectively, lower and higher screen-positive rates when compared with those with measurements within the 0.95-1.05 UtA-PI MoM interval (7.2% and 13.2% vs 11.2%, respectively, P < 0.001). CONCLUSION: UtA Doppler is measured well among trained operators when following an established protocol. While slight variations are expected, systematic error in this measurement impacts on the screen-positive rate. Therefore, a quality control process should be in place and retraining of staff may be required. Copyright © 2018 ISUOG. Published by John Wiley & Sons Ltd.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Rolnik DL, da Silva Costa F, Sahota D, et al. Quality assessment of uterine artery Doppler measurement in first-trimester combined screening for pre-eclampsia. Ultrasound Obstet Gynecol. 2019. PMID: 29917286. doi:10.1002/uog.19116

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。