文献速递产科母胎医学

引产前评估胎儿枕位与脊柱位置的可信度如何

How reliable is fetal occiput and spine position assessment prior to induction of labor?
PubMed 文献 · Ultrasound Obstet Gynecol · 2019-02-27

前瞻性纳入136名初产妇,在决定引产后立即行经腹超声确定胎头与脊柱位置,至少1小时后引产前再次评估。两次评估间枕位不一致34例(25.0%)、脊柱位置不一致40例(29.4%);枕后位在剖宫产组与阴道分娩组发生率无显著差异(19例(18.8%)vs 6例(17.1%);P=0.826)。作者认为引产前评估枕位与脊柱位置似乎与分娩方式无关,临床价值不大。

要点

  • 引产前两次超声评估中,25.0%孕妇枕位不一致、29.4%脊柱位置不一致,提示胎位动态变化。
  • 剖宫产组与阴道分娩组枕后位发生率无显著差异(18.8% vs 17.1%;P=0.826)。
  • 枕后位者引产至分娩间隔长于非枕后位者(1786±805 vs 1347±784 min;P=0.013)。

核心结论

  • 相当比例引产孕妇的胎儿枕位与脊柱位置呈动态变化,其评估似乎与分娩方式无关。
  • 作者认为引产前评估枕位与脊柱位置不太可能具有临床实用性。

研究设计与样本

  • 前瞻性研究,纳入136名初产妇,在决定引产后立即经腹超声确定胎头与脊柱位置。
  • 至少1小时后、引产前再次评估枕位与脊柱位置,并比较阴道分娩与剖宫产孕妇的胎位差异。

主要发现

  • 首次与第二次评估枕位分别为前位55例(40.4%)与62例(45.6%)、横位52例(38.2%)与49例(36.0%)、后位29例(21.3%)与25例(18.4%)。
  • 首次与第二次评估脊柱位置分别为前位58例(42.6%)与52例(38.2%)、横位42例(30.9%)与50例(36.8%)、后位36例(26.5%)与34例(25.0%)。
  • 两次评估枕位不一致34例(25.0%),脊柱位置不一致40例(29.4%)。
  • 剖宫产组与阴道分娩组枕后位发生率无显著差异(19例(18.8%)vs 6例(17.1%);P=0.826),脊柱后位发生率亦无显著差异(27例(26.7%)vs 7例(20%);P=0.428)。
  • 枕后位者引产至分娩间隔长于非枕后位者(1786±805 vs 1347±784 min;P=0.013)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To assess the reliability of fetal occiput and spine position determination in nulliparous women prior to induction of labor (IOL), and to evaluate identification of fetal occiput and spine positions prior to IOL in the prediction of labor outcome. METHODS: A series of 136 nulliparous women were recruited prospectively, immediately after the decision to perform IOL was made. Transabdominal ultrasound was performed to determine fetal head and spine positions. After at least 1 h, and prior to IOL, fetal occiput and spine positions were reassessed. Fetal occiput and spine positions were then compared between women who underwent vaginal delivery and those who delivered by Cesarean section. RESULTS: On the first and second assessments, respectively, fetal occiput position was anterior in 55 (40.4%) and 62 (45.6%) women, transverse in 52 (38.2%) and 49 (36.0%) women, and posterior in 29 (21.3%) and 25 (18.4%) women, while fetal spine position was anterior in 58 (42.6%) and 52 (38.2%) women, transverse in 42 (30.9%) and 50 (36.8%) women, and posterior in 36 (26.5%) and 34 (25.0%) women. Discordance between the first and second assessments of fetal occiput position was identified in 34 (25.0%) women, whereas discordance of fetal spine position was observed in 40 (29.4%) women. The incidence of fetal occiput posterior position in women undergoing Cesarean section was comparable to that in the vaginal-delivery group (19 (18.8%) vs 6 (17.1%); P = 0.826), which was similarly the case for fetal posterior spine position (27 (26.7%) vs 7 (20%); P = 0.428). Women with fetal occiput posterior position had a longer induction-to-delivery interval in comparison to those with non-occiput posterior fetal position (1786 ± 805 vs 1347 ± 784 min; P = 0.013). CONCLUSIONS: Fetal occiput and spine positions are dynamic in a considerable proportion of women undergoing IOL, and their assessment does not seem to correlate with mode of delivery. Occiput and spine position assessment in women prior to IOL is unlikely to be clinically useful. Copyright © 2018 ISUOG. Published by John Wiley & Sons Ltd.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Kamel R, Youssef A. How reliable is fetal occiput and spine position assessment prior to induction of labor? Ultrasound Obstet Gynecol. 2019. PMID: 29947161. doi:10.1002/uog.19169

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。