文献速递产科母胎医学生殖医学

辅助生殖技术后孕产妇产时及产后近失的发生情况:一项回顾性研究

Maternal intra- and postpartum near-miss following assisted reproductive technology: a retrospective study.
PubMed 文献 · BJOG · 2018-07-10

该回顾性队列研究纳入意大利Del Ponte医院2005至2016年分娩的650例辅助生殖技术(ART)妊娠与22803例自然妊娠,比较产时严重孕产妇疾病风险。ART组潜在危及生命情况和孕产妇近失的粗发生率均高于非ART组,调整后近失风险仍升高,供卵ART者风险更高。

要点

  • ART妊娠孕产妇近失调整后风险升高(自体卵aOR 3.61,供卵aOR 13.57)。
  • ART组潜在危及生命情况27.1% vs 非ART组5.7%,近失2.6% vs 0.3%。
  • 近失最常见原因为围产期子宫切除、输注≥5单位红细胞和需血管活性药物的心血管功能障碍。

核心结论

  • ART妊娠,尤其是供卵ART妊娠,产时潜在危及生命情况和近失风险升高,但不能排除未测混杂因素。

研究设计与样本

  • 回顾性队列研究,使用前瞻性维护的机构数据库,纳入2005至2016年意大利Del Ponte医院分娩的650例ART妊娠与22803例自然妊娠。

主要发现

  • 全队列近失发生率为3.3例/1000例分娩(95%CI 2.6-4.1)。
  • ART组与非ART组潜在危及生命情况粗发生率分别为27.1%与5.7%,近失分别为2.6%与0.3%。
  • 近失最常见三大原因为围产期子宫切除、输注≥5单位红细胞和需血管活性药物的心血管功能障碍。
  • 调整后近失风险:自体卵ART妊娠aOR 3.61(95%CI 1.61-8.09),供卵ART妊娠aOR 13.57(95%CI 5.45-33.77)。

关键数值与推荐

  • 采用世界卫生组织潜在危及生命情况和孕产妇近失死亡标准。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 不能排除未测混杂因素。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To assess whether risk of severe maternal morbidity at delivery differs for women who conceived using assisted reproductive technology (ART), compared with those with a spontaneous conception. DESIGN: A cohort study using a prospectively maintained institutional database. SETTING: A tertiary university maternity hospital. POPULATION: All women delivering at Del Ponte Hospital, Italy, between 2005 and 2016. METHODS: Data from 650 ART-conceived pregnancies were compared with 22 803 spontaneously conceived pregnancies. We used multivariable analysis to estimate the odds of severe maternal morbidity at delivery associated with ART conception, adjusting for maternal demographic and health factors, gestational age, and mode of delivery. MAIN OUTCOME MEASURES: The World Health Organization criteria for potentially life-threatening conditions and near-miss maternal mortality were used. RESULTS: The incidence of near-miss in the entire cohort was 3.3 cases per 1000 births (95% confidence interval, 95% CI, 2.6-4.1). The crude prevalences of potentially life-threatening conditions and maternal near-miss were higher among ART than among non-ART deliveries (27.1 versus 5.7% and 2.6 versus 0.3%, respectively). The three most common causes of maternal near-miss cases were peripartum hysterectomy, transfusion of ≥5 units of red blood cells, and cardiovascular dysfunction requiring vasoactive drugs. The odds of a maternal near-miss at delivery were increased for ART-conceived pregnancies compared with non-ART-conceived pregnancies (adjusted odds ratio, aOR 3.61, 95% CI 1.61-8.09, for ART-conceived pregnancies with autologous oocytes; aOR 13.57, 95% CI 5.45-33.77, for ART pregnancies conceived with donor oocytes). CONCLUSION: Although we cannot exclude unmeasured confounding, we found that pregnancies conceived via ART, especially those conceived with donor oocytes, are at increased risk of maternal potentially life-threatening conditions and near-miss at delivery. FUNDING: This research received no specific grant from any funding agency in the public, commercial, or not-for-profit sectors. TWEETABLE ABSTRACT: Conceiving through assisted reproductive technology increases the likelihood of maternal near miss.

来源:BJOG,查看原文。版权归原作者所有。

引用

  1. Cromi A, Marconi N, Casarin J, et al. Maternal intra- and postpartum near-miss following assisted reproductive technology: a retrospective study. BJOG. 2018. PMID: 29873186. doi:10.1111/1471-0528.15308

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。