文献速递产科

随机意大利产前枕位超声试验:真空吸引术前超声评估胎头位置

Randomised Italian Sonography for occiput POSition Trial Ante vacuum (R.I.S.POS.T.A.).
PubMed 文献 · Ultrasound Obstet Gynecol · 2018-11-08

这项在13家意大利产科医院开展的随机对照试验纳入孕37+0至41+6周单胎头位需真空吸引助产的孕妇,比较单用阴道检查与阴道检查联合经腹超声评估胎头位置对真空吸引失败所致急诊剖宫产的影响;因无效性中期分析提前终止,两组主要结局及母胎结局无显著差异。

要点

  • 随机分组后,阴道检查联合经腹超声组与单用阴道检查组在真空吸引失败所致急诊剖宫产率上无显著差异。
  • 联合超声组在随机化时非枕前位发生率更高,枕位诊断错误率更低。
  • 联合超声组会阴切开率高于单用阴道检查组。

核心结论

  • 这项提前终止的随机对照试验未显示真空吸引术前超声评估胎头位置能降低助产失败风险或母胎并发症。

研究设计与样本

  • 随机对照试验,2014年4月至2017年6月在13家意大利产科医院开展,纳入孕37+0至41+6周单胎头位需真空吸引助产的孕妇。
  • 计划每组653例,实际随机222例,最终分析221例,其中单用阴道检查组132例(59.7%),阴道检查联合经腹超声组89例(40.3%)。

主要发现

  • 因无效性中期分析试验提前终止。
  • 两组真空吸引失败所致急诊剖宫产率及其他母胎结局无显著差异。
  • 联合超声组随机化时非枕前位发生率高于单用阴道检查组,枕位诊断错误率低于单用阴道检查组。
  • 联合超声组会阴切开率高于单用阴道检查组。

局限性

  • 试验因无效性中期分析提前终止。
  • 实际随机222例,最终分析221例,远低于计划每组653例的样本量。
  • 原文结论称该提前终止的随机对照试验未显示获益。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To assess whether sonographic diagnosis of fetal head position before instrumental vaginal delivery can reduce the risk of failed vacuum extraction and improve delivery outcome. METHODS: Randomised Italian Sonography for occiput POSition Trial Ante vacuum (R.I.S.POS.T.A.) is a randomized controlled trial of term (37 + 0 to 41 + 6 weeks' gestation) singleton pregnancies with cephalic presentation requiring instrumental delivery by vacuum extraction, which was conducted between April 2014 and June 2017 and involved 13 Italian maternity hospitals. Patients were randomized to assessment of fetal head position before attempted instrumental delivery by either vaginal examination (VE) alone or VE plus transabdominal sonography (TAS). Primary outcome was incidence of emergency Cesarean section due to failed vacuum extraction. A sample size of 653 women per group was planned to compare the primary outcome between the two groups. The sample size estimation was based on the hypothesis that the risk of failed vacuum delivery in the VE group would be 5% and that ultrasound assessment of fetal position prior to vacuum extraction would decrease this risk to 2%. RESULTS: On interim analysis, the trial was stopped for futility. During this period, 222 women were randomized and 221 were included in the final data analysis, of whom 132 (59.7%) were randomized to evaluation of fetal head position by VE only and 89 (40.3%) to assessment by VE plus TAS prior to vacuum extraction. No significant differences were observed between the two groups with respect to incidence of emergency Cesarean section due to failed instrumental delivery and other maternal and fetal outcomes. Women randomized to assessment by VE plus TAS showed higher incidence of non-occiput anterior position of the fetal head at randomization and lower incidence of incorrect diagnosis of occiput position compared with women undergoing assessment by VE alone. A higher rate of episiotomy was noted in the women undergoing both VE and TAS compared with those in the VE-only group. CONCLUSIONS: Our prematurely discontinued randomized controlled trial did not demonstrate any benefit in terms of reduced risk of failed instrumental delivery or maternal and fetal morbidity in women undergoing sonographic assessment of fetal head position prior to vacuum extraction. Copyright © 2018 ISUOG. Published by John Wiley & Sons Ltd.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Ghi T, Dall'Asta A, Masturzo B, et al. Randomised Italian Sonography for occiput POSition Trial Ante vacuum (R.I.S.POS.T.A.). Ultrasound Obstet Gynecol. 2018. PMID: 29785716. doi:10.1002/uog.19091

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。