文献速递妇科

有症状盆腔器官脱垂女性阴道子宫托放置失败预测因素的前瞻性研究

Predictors for unsuccessful pessary fitting in women with symptomatic pelvic organ prolapse: a prospective study.
PubMed 文献 · BJOG · 2018-05-29

该前瞻性观察研究纳入2015年5月至2016年12月北京协和医院343例有症状盆腔器官脱垂女性,阴道子宫托放置成功率为88.0%。较高BMI与较短TVL是不成功放置的独立预测因素,TVL小于7.3cm者不适宜作为阴道子宫托候选者。

要点

  • 343例中302例放置成功,成功率88.0%。
  • 较高BMI与较短TVL是不成功放置的独立预测因素。
  • TVL小于7.3cm者不适宜作为阴道子宫托候选者。

核心结论

  • 较高BMI和较短TVL是不成功阴道子宫托放置的独立预测因素。
  • TVL小于7.3cm的患者不适宜作为阴道子宫托的候选者。

研究设计与样本

  • 前瞻性观察研究,纳入2015年5月至2016年12月北京协和医院妇产科343例有症状盆腔器官脱垂女性。
  • 放置成功定义为初次放置后2周仍继续使用。

主要发现

  • 302例放置成功,成功率为88.0%。
  • 成功组BMI为24.7±3.1 kg/m2,不成功组为25.7±3.8 kg/m2,OR 1.174,95%CI 1.055-1.307,P=0.003。
  • 成功组TVL为8.0(8-9)cm,不成功组为7.0(6.8-8)cm,OR 0.338,95%CI 0.223-0.513,P<0.001。
  • ROC曲线显示TVL小于7.3cm者不成功放置率更高,灵敏度=0.82,特异度=0.64。

关键数值与推荐

  • TVL小于7.3cm为不成功放置的预测阈值,灵敏度=0.82,特异度=0.64。
  • 较高BMI的OR为1.174,95%CI 1.055-1.307,P=0.003。
  • 较短TVL的OR为0.338,95%CI 0.223-0.513,P<0.001。

临床怎么用

  • 作者认为TVL小于7.3cm的患者不适宜作为阴道子宫托的候选者。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To evaluate the success rate of vaginal pessary fitting and identify the risk factors associated with unsuccessful pessary fitting in a large cohort of patients with symptomatic pelvic organ prolapse (POP). DESIGN: Prospective observational study. SETTING: The Department of Obstetrics and Gynaecology, Peking Union Medical College Hospital, Beijing, China. POPULATION: Women with symptomatic POP between May 2015 and December 2016 (n = 343). METHODS: A successful pessary fitting was defined as a patient fitted with a pessary at the initial fitting and continued use 2 weeks later. The independent samples t-test, non-parametric test, Chi-square test, Fisher's exact test, logistic regression and receiver operating characteristic curves were used for the data analysis. MAIN OUTCOME MEASURES: The success rate of vaginal pessary fitting and the risk factors associated with unsuccessful pessary fitting. RESULTS: 302 patients had successful pessary fitting (88.0% success rate). A higher body mass index [BMI; 24.7 ± 3.1 kg/m2 in the successful group versus 25.7 ± 3.8 kg/m2 in the unsuccessful group, odds ratio (OR) 1.174, 95% CI 1.055-1.307, P = 0.003] and a shorter TVL [8.0 (8-9) cm in the successful group versus 7.0 (6.8-8) cm in the unsuccessful group, OR 0.338, 95% CI 0.223-0.513, P < 0.001) were independent predictors of an unsuccessful pessary fitting. The receiver operating characteristic curve showed that patients with a total vaginal length (TVL) less than 7.3 cm had a higher unsuccessful pessary fitting rate (sensitivity = 0.82, specificity = 0.64). CONCLUSIONS: A higher BMI and shorter TVL were independent predictors of an unsuccessful pessary fitting. Patients with a TVL <7.3 cm are not appropriate candidates for a vaginal pessary. TWEETABLE ABSTRACT: A higher BMI and shorter TVL (<7.3 cm) were independent predictors of an unsuccessful pessary fitting.

来源:BJOG,查看原文。版权归原作者所有。

引用

  1. Mao M, Ai F, Zhang Y, et al. Predictors for unsuccessful pessary fitting in women with symptomatic pelvic organ prolapse: a prospective study. BJOG. 2018. PMID: 29700950. doi:10.1111/1471-0528.15260

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。