剖宫产子宫切口缝合中无结倒刺缝线与传统缝线的随机临床试验
在以色列Ziv医学中心开展的前瞻性非盲随机对照试验,将102名剖宫产产妇随机分为无结倒刺缝线组(51例)与传统缝线组(51例),比较子宫切口缝合时间、额外止血缝线需求和失血量。结果显示无结倒刺缝线组缝合时间平均缩短1分43秒(P<.001,95%CI 67.69-138.47秒),额外止血缝线需求更低(中位数0 vs 1,P<.001),缝合期间失血量更少(平均221 mL vs 268 mL,P<.005)。
要点
- 无结倒刺缝线组子宫切口缝合时间较传统缝线组平均缩短1分43秒(P<.001)。
- 无结倒刺缝线组额外止血缝线需求中位数为0,传统缝线组为1(P<.001)。
- 无结倒刺缝线组缝合期间失血量平均221 mL,传统缝线组268 mL(P<.005)。
核心结论
- 使用无结倒刺缝线是传统缝线的合理替代方案,因其缩短了子宫切口缝合时间,且额外止血缝线需求更少、估计失血量略低。
研究设计与样本
- 前瞻性、非盲、随机对照试验,在以色列Ziv医学中心开展。
- 共随机102名产妇,无结倒刺缝线组51例,传统缝线组51例。
- 主要结局为子宫切口缝合时间,从子宫上第一针缝线开始至获得子宫止血为止。
- 采用密封信封在手术室内于子宫缝合前随机分组,以尽量减少操作者偏倚。
主要发现
- 无结倒刺缝线组子宫切口缝合时间较传统缝线组平均缩短1分43秒(P<.001,95%CI 67.69-138.47秒)。
- 无结倒刺缝线组额外止血缝线需求中位数为0,传统缝线组为1(P<.001)。
- 无结倒刺缝线组缝合期间失血量平均221 mL,传统缝线组平均268 mL(P<.005)。
- 两组人口学特征及既往剖宫产次数相似。
临床怎么用
- 作者认为,无结倒刺缝线是传统缝线的合理替代方案,因其缩短了子宫切口缝合时间。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Knotless barbed sutures are monofilament sutures with barbs cut into them. These sutures self-anchor, maintaining tissue approximation without the need for surgical knots. OBJECTIVE: The hypothesis of this study was that knotless barbed suture could be used on the myometrium to close the hysterotomy at cesarean delivery. The objective was to compare uterine closure time, need for additional sutures, and blood loss between this and a conventional suture. STUDY DESIGN: This was a prospective, unblinded, randomized controlled trial conducted at the Ziv Medical Center, Zefat, Israel. The primary outcome was the length of time needed to close the uterine incision, which was measured from the start of the first suture on the uterus until obtaining uterine hemostasis. To minimize provider bias, women were randomized by sealed envelopes that were opened in the operating room just prior to uterine closure with either a bidirectional knotless barbed suture or conventional suture. Secondary outcomes included the number of additional hemostatic sutures needed and blood loss during incision closure. RESULTS: Patients were enrolled from August 2016 until March 2017. One hundred two women were randomized. Fifty-one had uterine closure with knotless barbed suture and 51 with conventional suture. The groups were similar for demographics as well as number of previous cesarean deliveries. Uterine closure time using the knotless barbed suture was significantly shorter than the conventional suture by a mean of 1 minute 43 seconds (P < .001, 95% confidence interval, 67.69-138.47 seconds). Knotless barbed sutures were associated with a lower need for hemostatic sutures (median 0 vs 1, P < .001), and blood loss measured during incision closure was significantly lower (mean 221 mL vs 268 mL, P < .005). CONCLUSION: The use of a knotless barbed suture is a reasonable alternative to conventional sutures because it reduced the closure time of the uterine incision. There was also less need for additional hemostatic sutures and slightly reduced estimated blood loss.
引用
- Peleg D, Ahmad RS, Warsof SL, et al. A randomized clinical trial of knotless barbed suture vs conventional suture for closure of the uterine incision at cesarean delivery. Am J Obstet Gynecol. 2018. PMID: 29496259. doi:10.1016/j.ajog.2018.01.043
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。