滑动征在再次剖宫产妇女孕晚期超声评估腹腔内粘连中的新应用
前瞻性观察研究纳入至少一次剖宫产史孕妇,孕晚期经腹超声评估深呼吸时子宫在腹肌筋膜深面滑动情况,以滑动消失为严重粘连高风险。59例完成研究,高风险组19例中16例术中证实,低风险组40例中35例证实;敏感度76.2%、特异度92.1%。
要点
- 孕晚期超声评估子宫滑动征可用于预测再次剖宫产腹腔内粘连风险。
- 滑动消失判为严重粘连高风险,滑动明显或中等判为低风险。
- 滑动征预测粘连敏感度76.2%、特异度92.1%,观察者间kappa 0.52、观察者内0.77。
核心结论
- 作者认为简单的超声征象或可区分有剖宫产史患者腹腔内粘连的高风险与低风险。
- 作者认为该技术可能有助于再次剖宫产患者的临床决策。
研究设计与样本
- 前瞻性观察研究,纳入有至少一次剖宫产史的孕妇,于本次妊娠孕晚期行经腹超声评估。
- 共检查63例有至少一次剖宫产史患者,59例完成研究并在本机构接受剖宫产。
主要发现
- 因子宫滑动消失判为严重粘连高风险的19例中,16例术中证实粘连。
- 判为低风险的40例中,35例术中证实无粘连。
- 滑动征预测再次剖宫产妇女存在腹腔内粘连的敏感度为76.2%,特异度为92.1%。
- 观察者间Cohen kappa系数为0.52,观察者内为0.77。
关键数值与推荐
- 深呼吸时子宫在腹肌筋膜深面滑动消失判为严重粘连高风险。
- 子宫滑动明显或中等判为低风险。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Intra-abdominal adhesions are associated with an increased risk of complications during repeat Cesarean section (CS), such as bladder and bowel injury, hemorrhage, infection and hysterectomy. We present a simple sonographic marker, the 'sliding sign' of the uterus, for the prediction of intra-abdominal adhesions in the third trimester of pregnancy in women undergoing repeat CS. METHODS: This was a prospective observational study of pregnant women with a history of at least one Cesarean delivery evaluated by transabdominal ultrasound during the third trimester of an ongoing pregnancy. In order to diagnose intra-abdominal adhesions, we assessed a sonographic sign, the sliding of the uterus under the inner part of the fascia of the abdominal muscles during deep breathing. Women were considered to be at high risk for severe adhesions if uterine sliding was absent and at low risk in the presence of obvious or moderate uterine sliding. A comparison between sonographic findings and intra-abdominal adhesions observed during surgery was performed. RESULTS: Of the 63 patients with one or more previous CS examined, 59 completed the study and underwent CS at our institution. In 16 of the 19 cases assigned to the high-risk group for severe adhesions due to absence of sliding of the uterus, the suspicion was confirmed at surgery. The prediction of low risk for adhesions was confirmed in 35 out of 40 patients. The sensitivity and specificity of the sliding sign in predicting presence of intra-abdominal adhesions in women undergoing repeat CS were 76.2% and 92.1%, respectively. Inter- and intraobserver correlation using Cohen's kappa coefficient were 0.52 and 0.77, respectively. CONCLUSION: Our data show that a simple sonographic sign might be able to discriminate between high and low risk for intra-abdominal adhesions in patients with a history of Cesarean delivery. This technique may aid clinical decisions in patients undergoing repeat CS. Copyright © 2018 ISUOG. Published by John Wiley & Sons Ltd.
引用
- Baron J, Tirosh D, Mastrolia SA, et al. Sliding sign in third-trimester sonographic evaluation of intra-abdominal adhesions in women undergoing repeat Cesarean section: a novel technique. Ultrasound Obstet Gynecol. 2018. PMID: 29575202. doi:10.1002/uog.19057
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。