文献速递妇科

吲哚菁绿近红外成像检测子宫内膜异位症病灶(Gre-Endo试验):一项先导研究

Near-Infrared Imaging with Indocyanine Green for Detection of Endometriosis Lesions (Gre-Endo Trial): A Pilot Study.
PubMed 文献 · J Minim Invasive Gynecol · 2018-03-15

单中心、前瞻性、单臂先导研究纳入27例子宫内膜异位症患者,在腹腔镜手术中使用静脉吲哚菁绿近红外成像(NIR-ICG)识别病灶,共切除116个可疑病灶,其中16个由NIR-ICG检出并切除,111个病理证实为子宫内膜异位症;NIR-ICG可能有助于术中诊断和识别隐匿病灶,但需更大样本前瞻性研究验证。

要点

  • 27例患者共切除116个可疑子宫内膜异位症病灶,111个病理阳性。
  • 白光成像已识别100个病灶,NIR-ICG额外检出并切除16个病灶。
  • NIR-ICG的敏感度82%、特异度97.9%、阳性预测值97.8%、阴性预测值82.3%。

核心结论

  • NIR-ICG可能作为术中诊断工具,用于确认可见的子宫内膜异位症病灶并识别隐匿病灶。
  • 作者认为需要更大样本的前瞻性研究来验证这些初步结果。

研究设计与样本

  • 单中心、前瞻性、单臂先导研究(加拿大任务组分类II-2)。
  • 研究在学术三级医疗与研究中心开展,纳入27例有症状的子宫内膜异位症患者。
  • 患者接受使用NIR-ICG的腹腔镜系统原型的腹腔镜手术。

主要发现

  • 27例患者共切除116个可疑子宫内膜异位症病灶,其中111个标本病理阳性。
  • 专家外科医生在白光成像下已识别100个病灶,其余16个通过NIR-ICG检出并切除。
  • 白光成像与NIR-ICG的阳性预测值分别为95%和97.8%,阴性预测值分别为86.2%和82.3%。
  • 白光成像与NIR-ICG的敏感度分别为85.6%和82%,特异度分别为95.2%和97.9%。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文结论指出需要更大样本的前瞻性研究来验证这些初步结果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

STUDY OBJECTIVE: To evaluate near-infrared radiation imaging with intravenous indocyanine green (NIR-ICG) during laparoscopic intervention to identify endometriosis lesions. DESIGN: A single-center, prospective, single-arm pilot study (Canadian Task Force classification II-2). SETTING: An academic tertiary care and research center. PATIENTS: Twenty-seven patients with symptomatic endometriosis were enrolled. INTERVENTIONS: Patients underwent laparoscopic surgery using a laparoscopic system prototype with NIR-ICG. MEASUREMENTS AND MAIN RESULTS: A total of 116 suspected endometriosis lesions were removed from 27 patients. One hundred lesions had already been visualized in white light imaging by an expert surgeon; the remaining 16 were detected and removed using NIR-ICG. A total of 111 specimens were positive for endometriosis pathology. Positive predictive value of 95% and 97.8% and negative predictive value of 86.2% and 82.3% were found by white light imaging and NIR-ICG, respectively, with sensitivity of 85.6% and 82% and specificity of 95.2% and 97.9%, respectively. CONCLUSION: NIR-ICG may be a tool for intraoperative diagnosis, confirmation of visible endometriosis lesions, and a marker for identifying occult endometriosis. Further prospective studies with a larger population sample are warranted to validate these encouraging preliminary results.

来源:J Minim Invasive Gynecol,查看原文。版权归原作者所有。

引用

  1. Cosentino F, Vizzielli G, Turco LC, et al. Near-Infrared Imaging with Indocyanine Green for Detection of Endometriosis Lesions (Gre-Endo Trial): A Pilot Study. J Minim Invasive Gynecol. 2018. PMID: 29551477. doi:10.1016/j.jmig.2018.02.023

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。