文献速递生殖医学

胚胎评估的可靠性与一致性:一项外部质量控制项目5年的结果

Reliability and agreement on embryo assessment: 5 years of an external quality control programme.
PubMed 文献 · Reprod Biomed Online · 2017-12-29

该研究评估了一个纳入标准化胚胎分级方案的形态学胚胎质量评估外部质量控制项目,为期5年,旨在确定IVF中心临床胚胎学家之间以及其与专家组意见之间的观察者间可靠性和一致性。按照GRRAS指南计算Gwet指数及阳性与阴性一致率。结果显示,中心与专家组之间胚胎形态学评估的可靠性较高(Gwet指数0.76;95%CI 0.70至0.84),良好胚胎的一致性高于差质量胚胎;多核化和空泡观察时可靠性低(Ppos分别为0.56和0.43);囊胚中内细胞团特征差异最大;胚胎最终处置决策的可靠性中等(Gwet指数0.51;95%CI 0.41至0.60)。结论认为,临床胚胎学家在早期卵裂期胚胎多核化和空泡评估以及囊胚内细胞团分类方面的能力需要提高。

要点

  • 中心与专家组胚胎形态学评估的可靠性较高,Gwet指数0.76(95%CI 0.70至0.84)。
  • 多核化或空泡观察时可靠性低,Ppos分别为0.56和0.43。
  • 囊胚内细胞团特征差异最大;胚胎最终处置决策可靠性中等(Gwet指数0.51)。

核心结论

  • 临床胚胎学家在评估早期卵裂期胚胎多核化和空泡以及确定囊胚内细胞团类别方面的能力需要提高。

研究设计与样本

  • 对纳入标准化胚胎分级方案的形态学胚胎质量评估外部质量控制项目进行为期5年的评估,按照GRRAS指南计算Gwet指数及阳性和阴性一致率。

主要发现

  • 胚胎形态学评估中,中心与专家组之间的可靠性较高(Gwet指数0.76;95%CI 0.70至0.84)。
  • 良好质量胚胎的一致性高于差质量胚胎。
  • 观察到多核化或空泡时可靠性低(Ppos分别为0.56和0.43)。
  • 囊胚中内细胞团特征呈现最大差异。
  • 胚胎最终处置决策中,中心与专家组之间的可靠性中等(Gwet指数0.51;95%CI 0.41至0.60)。

关键数值与推荐

  • 胚胎形态学评估中心与专家组间Gwet指数0.76(95%CI 0.70至0.84)。
  • 多核化时Ppos为0.56,空泡时Ppos为0.43。
  • 胚胎最终处置决策中心与专家组间Gwet指数0.51(95%CI 0.41至0.60)。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

An external quality-control programme for morphology-based embryo quality assessment, incorporating a standardized embryo grading scheme, was evaluated over a period of 5 years to determine levels of inter-observer reliability and agreement between practising clinical embryologists at IVF centres and the opinions of a panel of experts. Following Guidelines for Reporting Reliability and Agreement Studies, the Gwet index and proportion of positive (Ppos) and negative agreement were calculated. For embryo morphology assessment, a substantial degree of reliability was measured between the centres and the panel of experts (Gwet index: 0.76; 95% CI 0.70 to 0.84). The agreement was higher for good- versus poor-quality embryos. When multinucleation or vacuoles were observed, low levels of reliability were obtained (Ppos: 0.56 and 0.43, respectively). In blastocysts, the characteristic that presented the largest discrepancy was that related to the inner cell mass. In decisions about the final disposition of the embryo, reliability between centre and the panel of experts was moderate (Gwet index: 0.51; 95% CI 0.41 to 0.60). In conclusion, the ability of clinical embryologists to evaluate the presence of multinucleation and vacuoles in the early cleavage embryo, and to determine the category of the inner cell mass in blastocysts, needs to be improved.

来源:Reprod Biomed Online,查看原文。版权归原作者所有。

引用

  1. Martínez-Granados L, Serrano M, González-Utor A, et al. Reliability and agreement on embryo assessment: 5 years of an external quality control programme. Reprod Biomed Online. 2017. PMID: 29339017. doi:10.1016/j.rbmo.2017.12.008

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。