诊断性宫腔镜评估输卵管通畅性准确性:与腹腔镜对比的回顾性队列研究
该回顾性队列研究纳入2008至2016年间511例不孕女性,评估宫腔镜下输卵管口「流」效应预测输卵管通畅性的准确性。998条输卵管分析显示,宫腔镜评估「流」预测通畅性敏感性86.4%(95%CI 83.7-88.8)、特异性77.6%(95%CI 72.1-82.5),阳性预测值约91%。假阴性风险因素包括子宫肌瘤、同侧输卵管积水及输卵管周围粘连。
要点
- 宫腔镜下见输卵管口「流」效应预测通畅性敏感性86.4%、特异性77.6%,阳性预测值约91%。
- 子宫肌瘤、同侧输卵管积水及输卵管周围粘连是宫腔镜假阴性的风险因素。
- 了解宫腔镜输卵管「流」效应有助于规划不孕患者的个体化诊疗方案。
核心结论
- 宫腔镜下可见的输卵管「流」效应可准确预测输卵管通畅性,阳性预测值约91%。
- 了解宫腔镜输卵管「流」效应有助于规划个体患者的后续诊疗方案。
研究设计与样本
- 回顾性队列研究(加拿大特别工作组分类II-2)。
- 分析研究中心的2008年至2016年间因不孕接受手术的全部患者数据。
- 纳入511例同时接受宫腔镜和腹腔镜检查的不孕女性。
- 主要结局参数为腹腔镜亚甲蓝通液评估的输卵管通畅性。
主要发现
- 998条输卵管分析中,宫腔镜评估输卵管「流」预测通畅性高度准确(p < .001),敏感性86.4%(95%CI 83.7-88.8),特异性77.6%(95%CI 72.1-82.5)。
- 宫腔镜假阴性结果的风险因素包括子宫肌瘤(OR=2.11;95%CI 1.10-4.05;p=.025)、分析侧输卵管积水(OR=2.50;95%CI 1.17-5.34;p=.019)及分析输卵管周围粘连(OR=2.87;95%CI 1.21-6.76;p=.016)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
STUDY OBJECTIVE: To evaluate whether the presence of a visualizable "flow" effect in the fallopian tube ostia in hysteroscopic routine evaluation is predictive of tube patency. DESIGN: A retrospective cohort study (Canadian Task Force Classification II-2). SETTING: Data from all patients who underwent surgery because of infertility at the study center between 2008 and 2016 were analyzed retrospectively. The main outcome parameter was fallopian tube patency as assessed by laparoscopic chromopertubation. The predictive parameters tested were the presence of hysteroscopic tube "flow," general patient characteristics, and intraoperative findings. PATIENTS: Five hundred eleven infertile women who underwent combined hysteroscopy and laparoscopy were included. INTERVENTIONS: All women underwent combined hysteroscopy and laparoscopy. Some had other interventions when necessary, but no additional interventions were taken because of this study. RESULTS: In an analysis of 998 fallopian tubes, the hysteroscopic assessment of fallopian tube "flow" was highly accurate in predicting fallopian tube patency (p < .001), with a sensitivity of 86.4% (95% confidence interval [CI], 83.7-88.8) and a specificity of 77.6% (95% CI, 72.1-82.5). Risk factors for a false-negative hysteroscopy result were the presence of uterine myomas (odds ratio [OR] = 2.11; 95% CI, 1.10-4.05; p = .025), the presence of a hydrosalpinx on the analyzed side (OR = 2.50, 95% CI, 1.17-5.34; p = .019), and the presence of peritubal adhesions surrounding the analyzed tube (OR = 2.87; 95% CI, 1.21-6.76; p = .016). CONCLUSION: A visualizable tube "flow" in hysteroscopy was accurate in the prediction of tubal patency, with a positive predictive value of about 91%. Knowledge about hysteroscopic fallopian tube "flow" can help to plan the future approach in an individual patient.
引用
- Promberger R, Simek IM, Nouri K, et al. Accuracy of Tubal Patency Assessment in Diagnostic Hysteroscopy Compared with Laparoscopy in Infertile Women: A Retrospective Cohort Study. J Minim Invasive Gynecol. 2017. PMID: 29221993. doi:10.1016/j.jmig.2017.11.020
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。