文献速递生殖医学产科

平均孕囊直径与头臀长差值作为体外受精后早孕期妊娠丢失标志物的研究

Difference between mean gestational sac diameter and crown-rump length as a marker of first-trimester pregnancy loss after in vitro fertilization.
PubMed 文献 · Fertil Steril · 2017-11-23

该回顾性队列研究纳入2005年1月至2014年12月在爱荷华大学医院与诊所接受新鲜或冷冻自体胚胎移植后单胎妊娠的1243个IVF周期,分析孕45-56天超声测量的平均孕囊直径与头臀长差值(mGSD-CRL)与早孕期妊娠丢失及不良妊娠结局的关系。结果显示mGSD-CRL<5 mm组早孕期妊娠丢失率43.7%,显著高于5-9.99 mm组15.8%、10-14.99 mm组9.9%和≥15 mm组7.1%,但mGSD-CRL并不比单独mGSD或CRL更能预测妊娠丢失,且与新生儿出生体重、分娩孕周或其他妊娠并发症无相关性。

要点

  • IVF单胎妊娠中,mGSD-CRL<5 mm组早孕期妊娠丢失率为43.7%,显著高于其他三组。
  • mGSD-CRL与早孕期妊娠丢失呈强负相关,但预测能力并不优于单独mGSD或CRL。
  • mGSD-CRL<5 mm且妊娠持续超过20周者,并发症风险未增加。

核心结论

  • 在IVF患者中,mGSD-CRL与早孕期妊娠丢失呈强负相关,但mGSD-CRL<5 mm时的妊娠丢失发生率显著低于既往报道。
  • mGSD-CRL较小与妊娠持续超过20周者的并发症风险增加无关。
  • mGSD、CRL与流产之间的关联是复杂的。

研究设计与样本

  • 回顾性队列研究,纳入2005年1月至2014年12月在爱荷华大学医院与诊所接受新鲜或冷冻自体胚胎移植后单胎妊娠的1243个IVF周期。
  • 纳入周期均包含孕45-56天的超声mGSD和CRL测量。

主要发现

  • 早孕期妊娠丢失率在mGSD-CRL<5 mm组为43.7%,显著高于5-9.99 mm组15.8%、10-14.99 mm组9.9%和≥15 mm组7.1%。
  • mGSD-CRL与新生儿出生体重、分娩孕周或其他妊娠并发症均无相关性。
  • mGSD-CRL对妊娠丢失的预测并不优于单独mGSD或CRL。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To investigate whether the difference between mean gestational sac diameter and crown-rump length (mGSD - CRL) is associated with first-trimester pregnancy loss or adverse pregnancy outcomes after in vitro fertilization (IVF) and to determine if mGSD - CRL is a better predictor of pregnancy loss than either measurement alone. DESIGN: Retrospective cohort study. SETTING: University hospital. PATIENT(S): A total of 1,243 IVF cycles with fresh or cryopreserved autologous embryo transfers resulting in singleton gestations performed at the University of Iowa Hospitals and Clinics from January 2005 through December 2014. Cycles included ultrasound measurements of mGSD and CRL at 45-56 days' gestation. INTERVENTION(S): Mean gestational sac diameter to crown-rump length difference. MAIN OUTCOME MEASURE(S): Primary outcomes were first-trimester pregnancy loss and gestational age at delivery. Secondary outcomes were infant birth weight and pregnancy complications. RESULT(S): First-trimester pregnancy loss rates were significantly higher in pregnancies with mGSD - CRL <5 mm (43.7%) compared with 5-9.99 mm (15.8%), 10-14.99 mm (9.9%), and ≥15 mm (7.1%). No correlations were found with infant birth weight, gestational age at delivery, or other pregnancy complications. mGSD - CRL was not a better predictor of pregnancy loss than mGSD or CRL alone. CONCLUSION(S): There is a strong inverse relationship between mGSD - CRL and first-trimester pregnancy loss in IVF patients, although the incidence of pregnancy loss with a mGSD - CRL <5 mm was significantly lower than previously reported. Small mGSD - CRL was not associated with an increased risk of complications in pregnancies that continued beyond 20 weeks. The association between mGSD, CRL, and miscarriage is complex.

来源:Fertil Steril,查看原文。版权归原作者所有。

引用

  1. Kapfhamer JD, Palaniappan S, Summers K, et al. Difference between mean gestational sac diameter and crown-rump length as a marker of first-trimester pregnancy loss after in vitro fertilization. Fertil Steril. 2017. PMID: 29175064. doi:10.1016/j.fertnstert.2017.09.031

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。