文献速递妇科

经阴道超声与磁共振成像诊断深部浸润型子宫内膜异位症的系统评价与Meta分析

Transvaginal ultrasound vs magnetic resonance imaging for diagnosing deep infiltrating endometriosis: systematic review and meta-analysis.
PubMed 文献 · Ultrasound Obstet Gynecol · 2018-01-01

该系统评价纳入6项研究(n=424),比较经阴道超声(TVS)与磁共振成像(MRI)诊断深部浸润型子宫内膜异位症(DIE)的准确性。结果显示两种技术在直肠乙状结肠、直肠阴道隔和宫骶韧带部位的诊断性能相似。

要点

  • TVS与MRI诊断直肠乙状结肠DIE的汇总敏感度均为0.85,特异度分别为0.96和0.95。
  • 直肠阴道隔DIE:MRI汇总敏感度0.66,TVS为0.59;特异度均为0.97。
  • 宫骶韧带DIE:MRI汇总敏感度0.70,TVS为0.67;特异度分别为0.93和0.86。

核心结论

  • TVS与MRI检测累及直肠乙状结肠、宫骶韧带和直肠阴道隔的DIE的诊断性能相似。

研究设计与样本

  • 系统评价与Meta分析,检索PubMed/MEDLINE和Web of Science 1989年1月至2016年10月的文献。
  • 纳入标准为同一组疑诊DIE患者中同时行TVS和MRI并以手术数据为参考标准的研究。
  • 共纳入6项研究,样本量n=424;使用QUADAS-2工具评估质量,采用随机效应模型。

主要发现

  • 直肠乙状结肠DIE:MRI汇总敏感度0.85(95%CI 0.78-0.90),特异度0.95(95%CI 0.83-0.99),LR+ 18.4(95%CI 4.7-72.4),LR- 0.16(95%CI 0.11-0.24),DOR 116(95%CI 23-585)。
  • 直肠乙状结肠DIE:TVS汇总敏感度0.85(95%CI 0.68-0.94),特异度0.96(95%CI 0.85-0.99),LR+ 20.4(95%CI 4.7-88.5),LR- 0.16(95%CI 0.07-0.38),DOR 127(95%CI 14-1126)。
  • 直肠阴道隔DIE:MRI汇总敏感度0.66(95%CI 0.51-0.79),特异度0.97(95%CI 0.89-0.99),LR+ 22.5(95%CI 6.7-76.2),LR- 0.38(95%CI 0.23-0.52),DOR 65(95%CI 21-204)。
  • 直肠阴道隔DIE:TVS汇总敏感度0.59(95%CI 0.26-0.86),特异度0.97(95%CI 0.94-0.99),LR+ 23.5(95%CI 9.1-60.5),LR- 0.42(95%CI 0.18-0.97),DOR 56(95%CI 11-275)。
  • 宫骶韧带DIE:MRI汇总敏感度0.70(95%CI 0.55-0.82),特异度0.93(95%CI 0.87-0.97),LR+ 10.4(95%CI 5.1-21.2),LR- 0.32(95%CI 0.20-0.51),DOR 32(95%CI 12-85);TVS汇总敏感度0.67(95%CI 0.55-0.77),特异度0.86(95%CI 0.73-0.93),LR+ 4.8(95%CI 2.6-9.0),LR- 0.38(95%CI 0.29-0.50),DOR 12(95%CI 7-24)。

关键数值与推荐

  • 所有部位两种技术的汇总敏感度、特异度和DOR的置信区间均较宽。
  • 多数评估部位的敏感度和特异度异质性为中等或较高。
  • 根据QUADAS-2,纳入研究多数领域的质量被认为良好。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 所有部位两种技术的汇总敏感度、特异度和DOR的置信区间均较宽。
  • 多数评估部位的敏感度和特异度异质性为中等或较高。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To perform a systematic review of studies comparing the accuracy of transvaginal ultrasound (TVS) and magnetic resonance imaging (MRI) in diagnosing deep infiltrating endometriosis (DIE) including only studies in which patients underwent both techniques. METHODS: An extensive search was carried out in PubMed/MEDLINE and Web of Science for papers from January 1989 to October 2016 comparing TVS and MRI in DIE. Studies were considered eligible for inclusion if they reported on the use of TVS and MRI in the same set of patients for the preoperative detection of endometriosis in pelvic locations in women with clinical suspicion of DIE and using surgical data as a reference standard. Quality was assessed using the QUADAS-2 tool. A random-effects model was used to determine pooled sensitivity, specificity, positive and negative likelihood ratios (LR+ and LR-) and diagnostic odds ratio (DOR). RESULTS: Of 375 citations identified, six studies (n = 424) were considered eligible. For MRI in the detection of DIE in the rectosigmoid, pooled sensitivity was 0.85 (95% CI, 0.78-0.90), specificity was 0.95 (95% CI, 0.83-0.99), LR+ was 18.4 (95% CI, 4.7-72.4), LR- was 0.16 (95% CI, 0.11-0.24) and DOR was 116 (95% CI, 23-585). For TVS in the detection of DIE in the rectosigmoid, pooled sensitivity was 0.85 (95% CI, 0.68-0.94), specificity was 0.96 (95% CI, 0.85-0.99), LR+ was 20.4 (95% CI, 4.7-88.5), LR- was 0.16 (95% CI, 0.07-0.38) and DOR was 127 (95% CI, 14-1126). For MRI in the detection of DIE in the rectovaginal septum, pooled sensitivity was 0.66 (95% CI, 0.51-0.79), specificity was 0.97 (95% CI, 0.89-0.99), LR+ was 22.5 (95% CI, 6.7-76.2), LR- was 0.38 (95% CI, 0.23-0.52) and DOR was 65 (95% CI, 21-204). For TVS in the detection of DIE in the rectovaginal septum, pooled sensitivity was 0.59 (95% CI, 0.26-0.86), specificity was 0.97 (95% CI, 0.94-0.99), LR+ was 23.5 (95% CI, 9.1-60.5), LR- was 0.42 (95% CI, 0.18-0.97) and DOR was 56 (95% CI, 11-275). For MRI in the detection of DIE in the uterosacral ligaments, pooled sensitivity was 0.70 (95% CI, 0.55-0.82), specificity was 0.93 (95% CI, 0.87-0.97), LR+ was 10.4 (95% CI, 5.1-21.2), LR- was 0.32 (95% CI, 0.20-0.51) and DOR was 32 (95% CI, 12-85). For TVS in the detection of DIE in the uterosacral ligaments, pooled sensitivity was 0.67 (95% CI, 0.55-0.77), specificity was 0.86 (95% CI, 0.73-0.93), LR+ was 4.8 (95% CI, 2.6-9.0), LR- was 0.38 (95% CI, 0.29-0.50) and DOR was 12 (95% CI, 7-24). Confidence intervals of pooled sensitivities, specificities and DOR were wide for both techniques in all the locations considered. Heterogeneity was moderate or high for sensitivity and specificity for both TVS and MRI in most locations assessed. According to QUADAS-2, the quality of the included studies was considered good for most domains. CONCLUSION: The diagnostic performance of TVS and MRI is similar for detecting DIE involving rectosigmoid, uterosacral ligaments and rectovaginal septum. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Guerriero S, Saba L, Pascual MA, et al. Transvaginal ultrasound vs magnetic resonance imaging for diagnosing deep infiltrating endometriosis: systematic review and meta-analysis. Ultrasound Obstet Gynecol. 2018. PMID: 29154402. doi:10.1002/uog.18961

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。