文献速递产科母胎医学

妊娠晚期子宫动脉搏动指数的观察者内与观察者间可重复性

Intraobserver and interobserver reproducibility of third trimester uterine artery pulsatility index.
PubMed 文献 · Prenat Diagn · 2017-11-08

该前瞻性研究纳入101例已知体重指数的单胎妊娠孕妇,于孕30+0至40+0周由两名胎儿医学基金会认证操作者独立盲法测量子宫动脉搏动指数。观察者内和观察者间可重复性仅为差至中等,区分正常与病理测量的操作者间一致性为中等,未发现体重指数或孕龄与测量可重复性相关。

要点

  • 妊娠晚期子宫动脉搏动指数的观察者内与观察者间可重复性仅为差至中等。
  • 观察者内和观察者间区分正常与病理值的Cohen kappa分别为0.478和0.418,一致性中等。
  • 未发现母亲体重指数或孕龄与测量可重复性之间存在相关性。

核心结论

  • 妊娠晚期子宫动脉搏动指数经组内相关系数、一致性相关系数和Bland-Altman一致性界限评估,观察者内与观察者间可重复性仅为中等至差。
  • 操作者间在定义病理与正常测量时的一致性为中等。

研究设计与样本

  • 前瞻性研究,纳入已知体重指数的单胎妊娠孕妇,孕周30+0至40+0周,共101例获得测量。
  • 由两名胎儿医学基金会认证操作者独立、盲法进行子宫动脉搏动指数多普勒测量。
  • 采用一致性相关系数和组内相关系数评估可重复性,构建Bland-Altman图并计算一致性界限,对原始数值和百分位数均进行分析。
  • 将测量分为子宫动脉搏动指数<第95百分位/≥第95百分位两类,计算Cohen kappa系数评估操作者内和操作者间在定义正常与病理测量时的一致性。
  • 采用Spearman相关系数研究母亲体重指数和孕龄与子宫动脉测量准确性的相关性。

主要发现

  • 观察者内可重复性:原始值的组内相关系数为0.912、一致性相关系数为0.835;百分位数的组内相关系数为0.837、一致性相关系数为0.716。
  • 观察者间可重复性:原始值的组内相关系数为0.809、一致性相关系数为0.732;百分位数的组内相关系数为0.677、一致性相关系数为0.576。
  • 一致性界限较宽,最小为-0.30至0.35,最大为-0.53至0.62。
  • Cohen kappa系数操作者内为0.478、操作者间为0.418,显示区分正常与病理值的一致性为中等。
  • 未发现母亲体重指数和孕龄与测量可重复性之间存在相关性。

关键数值与推荐

  • 可重复性结果依据True Reproducibility of Ultrasound Techniques综述报告的截断值进行解读。
  • 子宫动脉搏动指数百分位数分类阈值为第95百分位。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: The primary aim of the study was to investigate intraobserver and interobserver reproducibility of uterine artery (UtA) pulsatility index (PI) in the third trimester of pregnancy. The secondary aim of the study was to examine whether high maternal body mass index (BMI) or gestational age (GA) influence the reliability of this measurement. METHODS: Singleton pregnancies in women with known BMI were recruited between 30+0 and 40+0 weeks. UtA PI Doppler measurements were performed prospectively, independently, and blindly by 2 Fetal Medicine Foundation-accredited operators. Intraobserver and interobserver reproducibility was assessed by concordance correlation coefficient (CCC) and intraclass correlation coefficient (ICC); Bland-Altman plots were built and limits of agreement (LoA) were calculated. The analysis was performed for both raw numbers and percentiles. To estimate the intraoperator and interoperator agreement in defining normal and pathological measurements, the assessments were divided in 2 categories-UtA PI <95th percentile/ ≥95th percentile-and Cohen's kappa coefficients were calculated. Results were interpreted according to the cutoffs reported by the True Reproducibility of Ultrasound Techniques review. Correlation between maternal BMI and GA and accuracy of UtA measurements was studied with Spearman's correlation coefficient. RESULTS: Measurements were available in 101 women. For intraobserver reproducibility, ICCs and CCCs were calculated for raw values and percentiles and were 0.912 and 0.835, and 0.837 and 0.716, respectively. For interobserver reproducibility, ICCs and CCCs were 0.809 and 0.732, and 0.677 and 0.576, respectively. This indicates a poor-moderate reproducibility of third trimester UtA PI. LoA were also wide (from a minimum of -0.30-0.35 to a maximum of -0.53-0.62). Cohen's kappa coefficients were 0.478 and 0.418, showing a moderate intraoperator and interoperator agreement in distinguishing between normal and pathological values. No correlation was found between maternal BMI and GA and reproducibility of the measurements. CONCLUSIONS: Intraobserver and interobserver reproducibility of third trimester UtA PI as assessed by ICC, CCC, and LoA is only moderate-poor. The agreement between operators in defining pathological and normal measurements is moderate.

来源:Prenat Diagn,查看原文。版权归原作者所有。

引用

  1. Marchi L, Gaini C, Franchi C, et al. Intraobserver and interobserver reproducibility of third trimester uterine artery pulsatility index. Prenat Diagn. 2017. PMID: 28960414. doi:10.1002/pd.5163

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。