文献速递生殖医学

人植入前胚胎早期时差成像标志物自动与手动标注的前瞻性研究

Prospective study of automated versus manual annotation of early time-lapse markers in the human preimplantation embryo.
PubMed 文献 · Hum Reprod · 2017-01-01

本研究前瞻性纳入本机构2014年8月至2016年2月在Eeva™系统(8台显微镜)中培养的1477枚胚胎,比较Eeva™ version 2.2自动标注与经认证胚胎学家手动标注2细胞期(P2)和3细胞期(P3)时差标志物的一致性及囊胚预测效能。手动标注对更高比例胚胎给出评级且囊胚预测敏感性优于自动标注,但P3相关性较低,30.0%胚胎存在不一致。

要点

  • 手动标注对更高比例胚胎给出评级,囊胚预测敏感性优于Eeva™自动标注。
  • P2相关性(ρ=0.75;ICC=0.82;95%CI 0.82-0.83)高于P3(ρ=0.39;ICC=0.20;95%CI 0.16-0.26)。
  • 30.0%(443/1477)胚胎评级不一致,手动标注将其中82.6%上调评级。

核心结论

  • 手动标注优于Eeva™ version 2.2自动标注,因手动标注对更高比例胚胎给出评级且囊胚预测敏感性更高。
  • 基于不一致比例及手动标注的更优表现,使用Eeva™系统的诊所应考虑手动标注P2和P3以确认Eeva™自动评级。

研究设计与样本

  • 前瞻性队列研究,纳入本机构2014年8月至2016年2月在Eeva™系统(8台显微镜)中培养的胚胎1477枚。
  • 由10人胚胎学家团队中的一人手动标注每枚胚胎,若自动与手动评级不同则由第二人独立标注。
  • 计算Spearman相关(ρ)、加权kappa统计量及组内相关系数(ICC)及95%CI,并计算不一致胚胎比例及各方法囊胚预测的敏感性、特异性、阳性预测值(PPV)和阴性预测值(NPV)。

主要发现

  • H、M、L评级分布因标注方法不同而异(P < 0.0001)。
  • Eeva™与手动标注的相关性P2(ρ=0.75;ICC=0.82;95%CI 0.82-0.83)高于P3(ρ=0.39;ICC=0.20;95%CI 0.16-0.26)。
  • Eeva™较胚胎学家更可能将胚胎评为NR(11.1% vs. 3.0%,P < 0.0001)。
  • 不一致发生于30.0%(443/1477)胚胎,与直接分裂(P2 ≤ 5 h)和短P3(≤0.25 h)及Eeva™系统内在因素相关。
  • 按评级不一致比例:H 9.3%、M 18.1%、L 41.3%、NR 31.4%(P < 0.0001);微孔位置周边31.2% vs 中心23.8%(P = 0.02);Eeva™显微镜(n=8)范围22.9-42.6%(P < 0.0001)。

临床怎么用

  • 使用Eeva™系统的诊所应考虑手动标注P2和P3以确认Eeva™自动评级(作者建议)。

局限性

  • 手动标注由同一团队胚胎学家完成,但研究 staff 由公司申办方培训并认证。
  • 仅评估两个时差标志物,结果不能推广至其他参数;同样不能推广至未来版本Eeva™或其他自动图像分析系统。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

STUDY QUESTION: How does automated time-lapse annotation (Eeva™) compare to manual annotation of the same video images performed by embryologists certified in measuring durations of the 2-cell (P2; time to the 3-cell minus time to the 2-cell, or t3-t2) and 3-cell (P3; time to 4-cell minus time to the 3-cell, or t4-t3) stages? SUMMARY ANSWER: Manual annotation was superior to the automated annotation provided by Eeva™ version 2.2, because manual annotation assigned a rating to a higher proportion of embryos and yielded a greater sensitivity for blastocyst prediction than automated annotation. WHAT IS KNOWN ALREADY: While use of the Eeva™ test has been shown to improve an embryologist's ability to predict blastocyst formation compared to Day 3 morphology alone, the accuracy of the automated image analysis employed by the Eeva™ system has never been compared to manual annotation of the same time-lapse markers by a trained embryologist. STUDY DESIGN, SIZE, DURATION: We conducted a prospective cohort study of embryos (n = 1477) cultured in the Eeva™ system (n = 8 microscopes) at our institution from August 2014 to February 2016. PARTICIPANTS/MATERIALS, SETTING, METHODS: Embryos were assigned a blastocyst prediction rating of High (H), Medium (M), Low (L), or Not Rated (NR) by Eeva™ version 2.2 according to P2 and P3. An embryologist from a team of 10, then manually annotated each embryo and if the automated and manual ratings differed, a second embryologist independently annotated the embryo. If both embryologists disagreed with the automated Eeva™ rating, then the rating was classified as discordant. If the second embryologist agreed with the automated Eeva™ score, the rating was not considered discordant. Spearman's correlation (ρ), weighted kappa statistics and the intra-class correlation (ICC) coefficients with 95% confidence intervals (CI) between Eeva™ and manual annotation were calculated, as were the proportions of discordant embryos, and the sensitivity, specificity, positive predictive value (PPV) and NPV of each method for blastocyst prediction. MAIN RESULTS AND THE ROLE OF CHANCE: The distribution of H, M and L ratings differed by annotation method (P < 0.0001). The correlation between Eeva™ and manual annotation was higher for P2 (ρ = 0.75; ICC = 0.82; 95% CI 0.82-0.83) than for P3 (ρ = 0.39; ICC = 0.20; 95% CI 0.16-0.26). Eeva™ was more likely than an embryologist to rate an embryo as NR (11.1% vs. 3.0%, P < 0.0001). Discordance occurred in 30.0% (443/1477) of all embryos and was not associated with factors such as Day 3 cell number, fragmentation, symmetry or presence of abnormal cleavage. Rather, discordance was associated with direct cleavage (P2 ≤ 5 h) and short P3 (≤0.25 h), and also factors intrinsic to the Eeva™ system, such as the automated rating (proportion of discordant embryos by rating: H: 9.3%; M: 18.1%; L: 41.3%; NR: 31.4%; P < 0.0001), microwell location (peripheral: 31.2%; central: 23.8%; P = 0.02) and Eeva™ microscope (n = 8; range 22.9-42.6%; P < 0.0001). Manual annotation upgraded 82.6% of all discordant embryos from a lower to a higher rating, and improved the sensitivity for predicting blastocyst formation. LIMITATIONS, REASONS FOR CAUTION: One team of embryologists performed the manual annotations; however, the study staff was trained and certified by the company sponsor. Only two time-lapse markers were evaluated, so the results are not generalizable to other parameters; likewise, the results are not generalizable to future versions of Eeva™ or other automated image analysis systems. WIDER IMPLICATIONS OF THE FINDINGS: Based on the proportion of discordance and the improved performance of manual annotation, clinics using the Eeva™ system should consider manual annotation of P2 and P3 to confirm the automated ratings generated by Eeva™. STUDY FUNDING/COMPETING INTEREST(S): These data were acquired in a study funded by Progyny, Inc. There are no competing interests. TRIAL REGISTRATION NUMBER: N/A.

来源:Hum Reprod,查看原文。版权归原作者所有。

引用

  1. Kaser DJ, Farland LV, Missmer SA, et al. Prospective study of automated versus manual annotation of early time-lapse markers in the human preimplantation embryo. Hum Reprod. 2017. PMID: 28854587. doi:10.1093/humrep/dex229

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。