孤立性完全性肺静脉异位连接胎儿的左心房大小及左心房-降主动脉距离Z评分
前瞻性横断面研究纳入333例20至40周正常单胎胎儿,建立左心房大小及左心房-降主动脉距离(LDD)的Z评分参考范围,并回顾10例产后确诊孤立性完全性肺静脉异位连接(TAPVC)胎儿。TAPVC胎儿左心房大小Z评分显著降低(80%低于-2),LDD Z评分显著升高(100%大于2);LDD Z评分>2.22鉴别TAPVC与正常心脏的敏感性100%、特异性98.5%。
要点
- 建立了20至40周正常胎儿左心房大小及LDD基于孕龄和胎儿生物学指标的Z评分参考范围。
- TAPVC胎儿左心房大小Z评分显著降低,80%(8/10)低于-2。
- TAPVC胎儿LDD Z评分显著升高,100%(10/10)大于2;LDD Z评分>2.22鉴别敏感性100%、特异性98.5%。
核心结论
- 提供了正常胎儿左心房大小及LDD基于孕龄和胎儿生物学指标的Z评分数据,可用于TAPVC的定量评估。
- LDD增大和左心房减小可能是产前诊断TAPVC的标记物。
研究设计与样本
- 前瞻性横断面研究纳入333例20至40周正常单胎胎儿,采用二维超声心动图获取6项心血管测量指标。
- 回顾10例产后确诊孤立性TAPVC胎儿的超声心动图,在存档图像上进行测量。
- 采用均值与标准差的回归分析,基于孕龄和胎儿生物学变量确定Z评分参考范围。
主要发现
- 正常病例中多数变量的均值和标准差最适合用简单线性回归模型描述,但基于孕龄的LDD均值最适合二次回归拟合。
- TAPVC胎儿左心房大小Z评分显著降低,其中80%(8/10)低于-2。
- TAPVC胎儿LDD Z评分显著升高,其中100%(10/10)大于2。
- LDD Z评分>2.22鉴别TAPVC与正常心脏的敏感性为100%、特异性为98.5%。
关键数值与推荐
- LDD Z评分>2.22鉴别TAPVC与正常心脏的敏感性100%、特异性98.5%。
- TAPVC胎儿中80%(8/10)左心房大小Z评分低于-2。
- TAPVC胎儿中100%(10/10)LDD Z评分大于2。
临床怎么用
- 原文未据此给出临床推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To construct Z-score reference ranges for fetal left atrial (LA) size and left atrium-descending aorta distance (LDD or 'post-LA distance') at 20 to 40 weeks' gestation and to compare these parameters between fetuses with isolated total anomalous pulmonary venous connection (TAPVC) and normal fetuses. METHODS: Three hundred thirty-three normal singleton fetuses from 20 to 40 weeks' gestation were enrolled in a prospective cross-sectional study. Six cardiovascular dimensions were obtained by two-dimensional echocardiography. Z-score reference ranges of these measurements were determined against gestational age (GA) and fetal biometric variables, using regression analysis of the mean and standard deviation. Also, we reviewed fetal echocardiograms from ten fetuses with postnatal diagnosis of isolated TAPVC and made the measurements on archived images. Subsequently, all parameters were compared between the normal and TAPVC groups. RESULTS: A simple linear regression model was the best description of the mean and standard deviation of most variables in normal cases, with the exception of the mean LDD based on GA, which was best fitted by a quadratic regression. Fetuses with TAPVC had significantly lower LA size Z-scores [80% (8/10) of which were under -2] and increased LDD Z-scores [100% (10/10) of which were greater than 2]. Using an LDD Z-score of >2.22 was both highly sensitive (100%) and specific (98.5%) for distinguishing between TAPVC and normal hearts. CONCLUSION: Normal data and Z-scores of fetal LA size and LDD were provided against GA and fetal biometry. This could be useful for quantitative assessment of fetal TAPVC. Increased post-LA distance and decreased LA size may be markers for the prenatal diagnosis of TAPVC. © 2017 John Wiley & Sons, Ltd.
引用
- Mao YK, Zhao BW, Zheng FH, et al. Z-scores for fetal left atrial size and left atrium-descending aorta distance in fetuses with isolated total anomalous pulmonary venous connection. Prenat Diagn. 2017. PMID: 28753739. doi:10.1002/pd.5119
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。