低风险人群中孕早期与孕中期经阴道超声宫颈长度的前瞻性研究
丹麦三个大学医院的前瞻性纵向研究纳入3477名单胎孕妇,在孕11-14周、19-21周和23-24周经阴道测量宫颈长度。孕早期宫颈长度≤25 mm者孕中期短宫颈风险约为≥35 mm者的9倍;但短宫颈比例低,实施普遍筛查的价值取决于成本效益分析。
要点
- 孕11-14周宫颈长度≤25 mm者孕中期短宫颈风险为17%,而≥35 mm者为2%。
- 孕中期宫颈长度≤25 mm的比例为2.0%(67/3232),其中38.8%在19-21周被检出。
- 在类似本研究人群中,19-21周筛查短宫颈需超过1500名孕妇才能预防一例34周前自发性早产。
核心结论
- 孕早期宫颈长度与孕中期短宫颈风险存在关联,一旦观察到短宫颈,早产风险大幅增加。
- 是否在低风险人群中实施普遍宫颈长度筛查取决于成本效益分析,需考虑短宫颈及早产风险人群比例低。
研究设计与样本
- 前瞻性纵向研究,2013年11月1日至2014年12月1日在丹麦三个大学医院招募单胎妊娠孕妇。
- 排除多胎妊娠、子宫畸形、入选时已行宫颈环扎或孕酮治疗者。
- 4904名合格孕妇中3477名(71%)参与并记录孕11-14周宫颈长度,其中3232名(93.0%)三次扫描均测量。
- 由受训操作者经阴道超声测量宫颈长度,取外口至内口直线距离;宫颈长度≤25 mm者转诊母胎医学专家按标准化方案治疗。
主要发现
- 孕11-14周宫颈长度中位数为37 mm,孕19-21周和23-24周中位数均为40 mm。
- 宫颈长度≤25 mm的比例随孕周增加,从孕11-14周的0.41%(95% CI,0.19-0.62%)升至孕23-24周的1.79%(95% CI,1.34-2.24%)。
- 孕中期(19-21周或23-24周)宫颈长度≤25 mm的比例为2.0%(n=67),其中38.8%(n=26)在19-21周被检出。
- 孕11-14周宫颈长度≤25 mm者孕中期短宫颈风险为17%,孕11-14周宫颈长度≥35 mm者为2%,前者约为后者的9倍。
- 孕11-14周宫颈长度预测孕中期短宫颈的效能为50%,假阳性率10%。
关键数值与推荐
- 孕11-14周宫颈长度≤25 mm者孕中期短宫颈风险为17%,≥35 mm者为2%。
- 孕中期宫颈长度≤25 mm的比例为2.0%(n=67),其中38.8%(n=26)在19-21周被检出。
- 在类似本研究人群中,19-21周筛查短宫颈需超过1500名孕妇才能预防一例34周前自发性早产。
临床怎么用
- 宫颈长度≤25 mm者转诊母胎医学专家按标准化管理方案治疗。
- 作者指出是否在低风险人群实施普遍宫颈长度筛查取决于成本效益分析。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To assess cervical length (CL) longitudinally between the first and second trimesters and to determine the proportion of women with short CL. The study also aimed to assess if women with short CL at 19-24 weeks' gestation could be identified at the time of combined first-trimester screening (cFTS) at 11-14 weeks' gestation, in order to determine the potential value of implementation of CL screening for prediction of preterm delivery in a Danish population. METHODS: This was a prospective longitudinal study of women with singleton pregnancy attending three University Hospitals in Denmark for combined first-trimester screening from 1 November 2013 to 1 December 2014. Exclusion criteria were multiple pregnancy, uterine anomaly, cerclage or progesterone treatment at inclusion. CL was measured on transvaginal sonography at 11-14 weeks (Cx1), 19-21 weeks (Cx2) and 23-24 weeks (Cx3), by trained operators as a straight line from external to internal os. Women with CL ≤ 25 mm were referred to a maternal-fetal medicine specialist for treatment according to a standardized management protocol. RESULTS: Of the 4904 eligible women, 3477 (71%) participated and had Cx1 recorded. Of those, 3232 (93.0%) had CL measured on all three scans. Median Cx1 was 37 mm, and median Cx2 and Cx3 were 40 mm. The proportion of women with CL ≤ 25 mm increased with gestational age, from 0.41% (95% CI, 0.19-0.62%) at Cx1 to 1.79% (95% CI, 1.34-2.24%) at Cx3. In total, the proportion of women with second-trimester CL (Cx2 or Cx3) ≤ 25 mm was 2.0% (n = 67), of which 38.8% (n = 26) were detected at 19-21 weeks. The probability of short CL between 19 and 24 weeks was greater for those with shorter first-trimester CL. It was nearly nine-fold higher for women with Cx1 ≤ 25 mm compared with Cx1 ≥ 35 mm (17% vs 2%). The performance of Cx1 for prediction of short second-trimester CL was 50% at a 10% false-positive rate. It was found that more than 1500 women would need to be screened for short CL at 19-21 weeks to prevent one case of spontaneous preterm delivery before 34 weeks in a population such as the one in this study. CONCLUSIONS: There is an association between first-trimester CL and risk of short cervix in the second trimester. Once short CL was observed, risk of preterm delivery was greatly increased. However, whether universal CL screening should be implemented in this low-risk population depends on cost-benefit analysis taking into account the low proportions of women with short CL and at risk for preterm delivery. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.
引用
- Wulff CB, Rode L, Rosthøj S, et al. Transvaginal sonographic cervical length in first and second trimesters in a low-risk population: a prospective study. Ultrasound Obstet Gynecol. 2018. PMID: 28639717. doi:10.1002/uog.17556
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。