文献速递生殖医学

血清HCG浓度对单枚新鲜或玻璃化冷冻复苏囊胚移植后妊娠的预测价值

Predictive value of serum HCG concentrations in pregnancies achieved after single fresh or vitrified-warmed blastocyst transfer.
PubMed 文献 · Reprod Biomed Online · 2017-05-30

研究评估单枚新鲜或玻璃化冷冻复苏囊胚移植后血清HCG水平的差异。1130例单囊胚移植HCG阳性中,789例新鲜移植、341例冷冻复苏移植;869例临床宫内妊娠中,638例新鲜移植、231例冷冻复苏移植。冷冻复苏移植后临床宫内妊娠的HCG水平显著高于新鲜移植(383 ± 230 IU/l vs 334 ± 192 IU/l,P = 0.01)。预测临床妊娠的阈值:新鲜囊胚111 IU/l,冷冻复苏囊胚137 IU/l。

要点

  • 冷冻复苏囊胚移植后临床宫内妊娠的初始血清HCG水平显著高于新鲜囊胚移植。
  • 预测临床妊娠的HCG阈值:新鲜囊胚111 IU/l,冷冻复苏囊胚137 IU/l。
  • 咨询患者时需注意冷冻复苏囊胚移植后需更高HCG水平预测临床宫内妊娠。

核心结论

  • 新鲜或冷冻复苏囊胚移植后总体β-HCG水平相当,提示玻璃化冷冻很可能不影响胚胎产生β-HCG的能力。
  • 冷冻复苏囊胚移植后需要更高的HCG水平来预测临床宫内妊娠,临床咨询时应考虑这一点。

研究设计与样本

  • 评估单枚新鲜或玻璃化冷冻复苏囊胚移植后血清HCG水平差异的研究。
  • 1130例单囊胚移植HCG阳性,其中新鲜移植789例、冷冻复苏移植341例。
  • 评估869例临床宫内妊娠的初始血清HCG水平,其中新鲜移植638例、冷冻复苏移植231例。

主要发现

  • 临床宫内妊娠的HCG水平:冷冻复苏囊胚移植383 ± 230 IU/l vs 新鲜囊胚移植334 ± 192 IU/l(P = 0.01),冷冻复苏组显著更高。
  • 预测临床妊娠的阈值:新鲜囊胚111 IU/l,冷冻复苏囊胚137 IU/l。

关键数值与推荐

  • 预测临床妊娠的HCG阈值:新鲜囊胚111 IU/l,冷冻复苏囊胚137 IU/l。

临床怎么用

  • 作者指出,临床医生咨询患者时应考虑冷冻复苏囊胚移植后需要更高的HCG水平来预测临床宫内妊娠。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Possible differences between serum HCG levels in pregnancies achieved after transfer of a single fresh or a vitrified-warmed blastocyst were evaluated. Out of 1130 single blastocyst transfers resulting in positive HCG results, 789 were single fresh blastocyst transfers and 341 single vitrified-warmed blastocyst transfers. The initial serum HCG levels of 869 clinical intrauterine pregnancies were evaluated, 638 after the transfer of a single fresh blastocysts and 231 after the transfer of a single vitrified-warmed blastocysts. The HCG levels from cycles resulting in a clinical intrauterine pregnancy were significantly higher after the transfer of a single vitrified-warmed blastocyst (383 ± 230 IU/l) versus a fresh transfer (334 ± 192 IU/l; P = 0.01). Threshold values for predicting a clinical pregnancy for a fresh blastocyst were 111 IU/l and for a vitrified-warmed blastocyst 137 IU/l. Our study shows that the overall beta-HCG levels are comparable after the transfer of a fresh or vitrified-warmed blastocyst, suggesting that vitrification most probably does not affect the ability of the embryos to produce beta-HCG. This study further shows that when clinicians counsel patients, they should take into account that higher HCG levels are needed after a vitrified-warmed blastocyst transfer to predict a clinical intrauterine pregnancy.

来源:Reprod Biomed Online,查看原文。版权归原作者所有。

引用

  1. Oron G, Shavit T, Esh-Broder E, et al. Predictive value of serum HCG concentrations in pregnancies achieved after single fresh or vitrified-warmed blastocyst transfer. Reprod Biomed Online. 2017. PMID: 28625759. doi:10.1016/j.rbmo.2017.05.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。