PubMed 文献 · Ultrasound Obstet Gynecol · 2018-08-05

该前瞻性盲法观察性队列研究纳入483例无并发症单胎妊娠妇女,自36周起每两周测量脑胎盘率(CPR)至分娩,分析437例。CPR<第10百分位阈值预测因产时胎儿窘迫(IFC)行剖宫产的敏感度为55.6%、特异度为87.9%,预测复合不良新生儿结局(ANO)的敏感度为28.2%、特异度为88.0%。CPR<第10百分位对IFC的预测价值仅为中等(AUC=0.72),对复合ANO的预测价值差(AUC=0.58)。

要点

  • CPR<第10百分位预测因IFC行剖宫产的敏感度55.6%、特异度87.9%。
  • CPR<第10百分位预测复合ANO的敏感度28.2%、特异度88.0%。
  • CPR<第10百分位对IFC的AUC=0.72,对复合ANO的AUC=0.58。

核心结论

  • CPR第10百分位阈值可能可作为足月低危妊娠因IFC行剖宫产风险评估工具的组成部分。

研究设计与样本

  • 前瞻性、盲法、观察性队列研究,纳入483例无并发症单胎妊娠妇女,自36周至分娩每两周测量CPR,记录产时及新生儿结局,最终437例纳入分析。

主要发现

  • 因IFC行急诊剖宫产者占4.1%,发生复合ANO者占17.8%。
  • CPR<第10百分位预测因IFC行剖宫产的敏感度为55.6%、特异度为87.9%。
  • CPR<第10百分位预测复合ANO的敏感度为28.2%、特异度为88.0%。
  • 与CPR≤1及<第5百分位相比,CPR<第10百分位对因IFC行剖宫产和复合ANO的总体检测性能最佳,但对因IFC行剖宫产的预测价值仅为中等(AUC=0.72),对复合ANO的预测价值差(AUC=0.58)。

关键数值与推荐

  • 复合ANO定义为出生时酸中毒、5分钟Apgar评分<7分和/或入住新生儿重症监护病房。
  • CPR<第10百分位预测因IFC行剖宫产:敏感度55.6%,特异度87.9%,AUC=0.72。
  • CPR<第10百分位预测复合ANO:敏感度28.2%,特异度88.0%,AUC=0.58。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Prediction of intrapartum fetal compromise in uncomplicated, term pregnancies is a global obstetric challenge. Currently, no widely accepted screening test for this condition exists, although the cerebroplacental ratio (CPR) shows promise. We aimed to evaluate prospectively the screening performance of the CPR 10th centile threshold for prediction of Cesarean section for intrapartum fetal compromise (IFC) and composite adverse neonatal outcome (ANO) after 36 weeks' gestation in low-risk women, and to compare this with CPR ≤ 1 and < 5th centile thresholds described previously in the literature. METHODS: This was a blinded, prospective, observational, cohort study of 483 women with uncomplicated singleton pregnancy who underwent fortnightly CPR measurements from 36 weeks to delivery, and their intrapartum and neonatal outcomes were recorded. The CPR 10th centile threshold screening performance was calculated for emergency Cesarean section for IFC and composite ANO (defined as acidosis at birth, 5-min Apgar score < 7 and/or admission to the neonatal intensive care unit). Comparison of screening performance of CPR ≤ 1 and < 5th and < 10th centile thresholds was also undertaken for these specified outcomes. RESULTS: In total, 437 women were included in the analysis, of whom 4.1% had an emergency Cesarean section for IFC and 17.8% had a composite ANO. Sensitivity and specificity for CPR < 10th centile were, respectively, 55.6% and 87.9% for prediction of Cesarean section for IFC, and 28.2% and 88.0% for composite ANO. Compared with CPR ≤ 1 and < 5th centile, CPR < 10th centile yielded the best overall test performance for detection of Cesarean section for IFC and composite ANO, although its predictive value was only fair for Cesarean section for IFC (area under the receiver-operating characteristics curve (AUC) = 0.72) and poor for composite ANO (AUC = 0.58). CONCLUSION: The CPR 10th centile threshold may be useful as a component of a risk assessment tool for Cesarean section for IFC in low-risk pregnancies at term. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Bligh LN, Alsolai AA, Greer RM, et al. Cerebroplacental ratio thresholds measured within 2 weeks before birth and risk of Cesarean section for intrapartum fetal compromise and adverse neonatal outcome. Ultrasound Obstet Gynecol. 2018. PMID: 28594099. doi:10.1002/uog.17542