使用简化MRI方法产前预测大于胎龄儿:与传统二维超声估测的比较
回顾性分析两组单胎孕妇数据,比较MRI估测胎儿体重与二维超声估测胎儿体重在预测大于胎龄儿中的表现。MRI在分娩前48小时内及超过48小时均显示预测大于胎龄儿的AUC显著高于超声,且半自动测量胎儿体积耗时中位数为3.5分钟。
要点
- 分娩前48小时内MRI-EFW预测出生体重≥90th百分位的AUC较US-EFW高0.085,差异有统计学意义。
- 分娩前48小时内MRI-EFW预测出生体重≥95th百分位的AUC较US-EFW高0.036,差异有统计学意义。
- 分娩前超过48小时MRI-EFW预测出生体重≥95th百分位的AUC较US-EFW高0.077,差异有统计学意义。
核心结论
- 使用目的设计的半自动MRI平面测量法不耗时,MRI-EFW在分娩前立即或远离分娩时预测大于胎龄儿的表现显著优于US-EFW。
研究设计与样本
- 回顾性研究,从数据库检索2011年3月至2016年5月间单胎孕妇数据,第一组为分娩前48小时内完成US-EFW和MRI-EFW者270例,第二组为孕35+0至37+6周之间、分娩前超过48小时完成评估者83例。
- US-EFW基于Hadlock等公式,MRI-EFW基于Baker等公式,MRI-EFW采用半自动方法测量胎儿体积并记录测量时间。
主要发现
- 第一组270例中48例(17.8%)新生儿出生体重≥90th百分位,30例(11.1%)≥95th百分位;第二组83例中9例(10.8%)新生儿出生体重≥95th百分位。
- 全部353例胎儿胎儿体积平面测量中位时间为3.5分钟(范围1.5-5.5分钟)。
- 分娩前48小时内MRI预测大于胎龄儿的AUC显著高于US:出生体重≥90th百分位时AUC差值=0.085,标准误=0.020,P<0.001;≥95th百分位时AUC差值=0.036,标准误=0.014,P=0.01。
- 分娩前超过48小时,MRI-EFW预测出生体重≥95th百分位的AUC优于US-EFW(AUC差值=0.077,标准误=0.039,P=0.045)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To evaluate the performance of a simple semi-automated method for estimation of fetal weight (EFW) using magnetic resonance imaging (MRI) as compared with two-dimensional (2D) ultrasound (US) for the prediction of large-for-dates neonates. METHODS: Data of two groups of women with singleton pregnancy between March 2011 and May 2016 were retrieved from our database and evaluated retrospectively: the first group included women who underwent US-EFW and MRI-EFW within 48 h before delivery and the second group included women who had these evaluations between 35 + 0 weeks and 37 + 6 weeks of gestation, more than 48 h before delivery. US-EFW was based on Hadlock et al. and MRI-EFW on the formula described by Baker et al. For MRI-EFW, planimetric measurement of the fetal body volume (FBV) was performed using a semi-automated method and the time required for measurement was noted. Outcome measure was the performance of MRI-EFW vs US-EFW in the prediction of large-for-dates neonates, both ≤ 48 h and > 48 h before delivery. Receiver-operating characteristics (ROC) curves for each method were compared using the DeLong method. RESULTS: Of the 270 women included in the first group, 48 (17.8%) newborns had birth weight ≥ 90th centile and 30 (11.1%) ≥ 95th centile. The second group included 83 women, and nine (10.8%) newborns had birth weight ≥ 95th centile. Median time needed for FBV planimetric measurements in all 353 fetuses was 3.5 (range, 1.5-5.5) min. The area under the ROC curve (AUC) for prediction of large-for-dates neonates by prenatal MRI performed within 48 h before delivery was significantly higher than that by US (for birth weight ≥ 90th centile, difference between AUCs = 0.085, standard error (SE) = 0.020, P < 0.001; for birth weight ≥ 95th centile, difference between AUCs = 0.036, SE = 0.014, P = 0.01). Similarly, MRI-EFW was better than US-EFW in predicting birth weight ≥ 95th centile when both examinations were performed > 48 h prior to delivery (difference between AUCs = 0.077, SE = 0.039, P = 0.045). CONCLUSION: MRI planimetry using our purpose-designed semi-automated method is not time-consuming. The predictive performance of MRI-EFW performed immediately prior to or remote from delivery is significantly better than that of US-EFW for the prediction of large-for-dates neonates. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.
引用
- Kadji C, Cannie MM, De Angelis R, et al. Prenatal prediction of postnatal large-for-dates neonates using a simplified MRI method: comparison with conventional 2D ultrasound estimates. Ultrasound Obstet Gynecol. 2018. PMID: 28508549. doi:10.1002/uog.17523
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。