文献速递产科母胎医学

电子时空图像相关技术提高四维胎儿超声心动图检查效率

Electronic spatiotemporal image correlation improves four-dimensional fetal echocardiography.
PubMed 文献 · Ultrasound Obstet Gynecol · 2018-02-07

一项随机对照试验纳入100例孕中期超声正常的患者,比较电子时空图像相关技术(eSTIC)与传统STIC获取四维胎儿心脏容积的诊断质量。eSTIC组获得最佳或满意诊断质量的比例为94%,高于传统STIC组的76%(P < 0.0001)。eSTIC未能获得充分质量容积均因胎儿体位不佳。

要点

  • eSTIC组获得最佳或满意诊断质量的比例为94%,传统STIC组为76%(P < 0.0001)。
  • eSTIC未能获得充分质量容积均因胎儿体位不佳。
  • 在标准胎儿解剖检查时间范围内,eSTIC可在超过90%的病例中获得可详细离线评估胎儿心脏的容积。

核心结论

  • 与标准机械探头相比,电子四维探头有助于获取孕中期胎儿的心脏超声容积。
  • 在本研究操作中,eSTIC在超过90%的病例中于标准胎儿解剖检查时间范围内获得最佳或满意诊断质量的容积,允许对胎儿心脏进行详细离线评估。

研究设计与样本

  • 随机对照试验,纳入100例孕中期超声正常的患者。
  • 半数病例使用传统机械四维探头获取胎儿心脏STIC容积,其余病例使用电子四维探头获取eSTIC容积。
  • 检查保持在标准胎儿解剖检查所分配的时间范围内,最多尝试两次获取四维心脏容积。
  • 数据集存储在计算机上,随后分析并分类为最佳、满意或不足质量,分类取决于是否能够执行扩展基础心脏检查,包括获取三血管气管切面以及矢状面清晰重建主动脉弓和动脉导管弓。

主要发现

  • eSTIC容积数据集获得最佳或满意诊断质量的比例为94%,传统STIC为76%(P < 0.0001)。
  • 未能获得充分质量eSTIC容积在所有病例中均因胎儿体位不佳。

临床怎么用

  • 与标准机械探头相比,电子四维探头有助于获取孕中期胎儿的心脏超声容积。
  • 在本研究操作中,eSTIC在超过90%的病例中于标准胎儿解剖检查时间范围内获得最佳或满意诊断质量的容积,允许对胎儿心脏进行详细离线评估。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To compare the efficiency of electronic spatiotemporal image correlation (eSTIC) with that of conventional STIC to acquire four-dimensional (4D) fetal cardiac volumes of diagnostic quality. METHODS: This was a randomized controlled trial of 100 patients in mid-gestation with normal sonograms. In half of the cases, STIC volumes of the fetal heart were obtained with a conventional mechanical 4D probe and in the remaining cases eSTIC volumes were obtained with an electronic 4D probe. Examinations were kept within the timeframe allotted for a standard examination of fetal anatomy, and a maximum of two attempts were made at obtaining a 4D cardiac volume. Datasets were stored on a computer and subsequently analyzed and categorized as being of optimal, satisfactory or inadequate quality, depending on whether or not it was possible to perform an extended basic cardiac examination, including obtaining a three vessels and trachea view, as well as a clear reconstruction of both the aortic and ductal arches in the sagittal plane. RESULTS: The eSTIC volume datasets were more frequently of optimal or satisfactory diagnostic quality compared with conventional STIC (94% vs 76%, P < 0.0001). Failure to obtain an eSTIC volume of adequate quality was in all cases the consequence of an unfavorable position of the fetus. CONCLUSIONS: Compared with a standard mechanical probe, the electronic 4D probe facilitates acquisition of sonographic cardiac volumes in mid-trimester fetuses. In our hands, eSTIC volumes of optimal or satisfactory diagnostic quality, allowing a detailed offline evaluation of the fetal heart, were obtained in more than 90% of cases within the time frame of a standard examination of fetal anatomy. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Guasina F, Bellussi F, Morganelli G, et al. Electronic spatiotemporal image correlation improves four-dimensional fetal echocardiography. Ultrasound Obstet Gynecol. 2018. PMID: 28337810. doi:10.1002/uog.17474

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。