低胎儿分数下无创产前筛查:全基因组测序与单核苷酸多态性方法的比较
该研究通过计算模型(参数来自已发表数据)比较全基因组测序(WGS)与单核苷酸多态性(SNP)方法在低胎儿分数下检测常见胎儿三体(T21、T18、T13)的性能,并回顾临床经验数据评估非整倍体检出率。SNP方法性能取决于三体起源,对最常见的母源M1不分离三体性能最低,在胎儿分数低于约3%时无法保持可接受性能;WGS方法特异性不依赖胎儿分数,在低胎儿分数样本中对三体的敏感性>80%。结论认为WGS方法在多数实验室发出无结果报告的胎儿分数阈值以下能检出更多非整倍体,避免不必要的侵入性操作。
要点
- SNP方法性能取决于三体起源,对母源M1不分离三体性能最低。
- SNP方法在胎儿分数低于约3%时无法保持可接受性能。
- WGS方法特异性不依赖胎儿分数,低胎儿分数样本中三体敏感性>80%。
核心结论
- WGS方法在多数实验室发出无结果报告的胎儿分数阈值以下能检出更多非整倍体,避免不必要的侵入性操作。
研究设计与样本
- 采用参数来自最新已发表数据的计算模型,比较WGS与SNP方法在低胎儿分数下检测常见胎儿三体(T21、T18、T13)的性能。
- 回顾临床经验数据,基于对近期侵入性筛查建议的依从性确定非整倍体检出率。
主要发现
- SNP方法性能取决于三体起源,对最常见的母源M1不分离三体性能最低。
- SNP方法在胎儿分数低于约3%时无法保持可接受性能。
- WGS方法保持高特异性且不依赖胎儿分数,在低胎儿分数样本中对三体的敏感性>80%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Performance of noninvasive prenatal screening (NIPS) methodologies when applied to low fetal fraction samples is not well established. The single-nucleotide polymorphism (SNP) method fails samples below a predetermined fetal fraction threshold, whereas some laboratories employing the whole-genome sequencing (WGS) method report aneuploidy calls for all samples. Here, the performance of the two methods was compared to determine which approach actually detects more fetal aneuploidies. METHODS: Computational models were parameterized with up-to-date published data and used to compare the performance of the two methods at calling common fetal trisomies (T21, T18, T13) at low fetal fractions. Furthermore, clinical experience data were reviewed to determine aneuploidy detection rates based on compliance with recent invasive screening recommendations. RESULTS: The SNP method's performance is dependent on the origin of the trisomy, and is lowest for the most common trisomies (maternal M1 nondisjunction). Consequently, the SNP method cannot maintain acceptable performance at fetal fractions below ~3%. In contrast, the WGS method maintains high specificity independent of fetal fraction and has >80% sensitivity for trisomies in low fetal fraction samples. CONCLUSION: The WGS method will detect more aneuploidies below the fetal fraction threshold at which many labs issue a no-call result, avoiding unnecessary invasive procedures. © 2017 Counsyl Inc. Prenatal Diagnosis published by John Wiley & Sons, Ltd.
引用
- Artieri CG, Haverty C, Evans EA, et al. Noninvasive prenatal screening at low fetal fraction: comparing whole-genome sequencing and single-nucleotide polymorphism methods. Prenat Diagn. 2017. PMID: 28317136. doi:10.1002/pd.5036
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。