文献速递产科

超声预测产钳分娩结局:一项多中心前瞻性队列研究

Sonographic prediction of outcome of vacuum deliveries: a multicenter, prospective cohort study.
PubMed 文献 · Am J Obstet Gynecol · 2017-03-19

本研究为2013至2016年在7个欧洲产科单位开展的前瞻性队列研究,纳入222例第二产程延长的初产妇,评估超声测量胎头位置和胎头会阴距离能否预测产钳分娩时长、分娩方式及胎儿结局。胎头会阴距离≤25 mm者产钳分娩中位时长6.0分钟,短于>25 mm者的8.0分钟;胎头会阴距离≤35 mm者剖宫产率3.9%,低于>35 mm者的22.0%(P<.01)。

要点

  • 胎头会阴距离≤25 mm者产钳分娩中位时长6.0分钟,短于>25 mm者的8.0分钟(对数秩检验<0.01)。
  • 胎头会阴距离≤35 mm者剖宫产7/181(3.9%),低于>35 mm者的9/41(22.0%)(P<.01)。
  • 胎头会阴距离≤35 mm者脐动脉pH<7.10为2/144(1.4%),低于>35 mm者的8/40(20.0%)(P<.01)。

核心结论

  • 超声有潜力预测第二产程延长产妇的分娩结局,所获信息可指导是否尝试产钳分娩或选择剖宫产、是否需要高年资医师在场以及是否在手术室进行产钳尝试。

研究设计与样本

  • 前瞻性队列研究,纳入2013至2016年7个欧洲产科单位中足月、第二产程延长的初产妇,共222例,按意向治疗分析。
  • 采用经腹部和经会阴超声分别测定胎头位置和胎头会阴距离,主要结局为产钳分娩时长与胎头会阴距离(预设切点25 mm)的关系。
  • 样本量按风险比1.5、80%把握度、α5%计算需220例;次要结局为分娩方式和出生后脐动脉血样。

主要发现

  • 胎头会阴距离≤25 mm者产钳分娩中位时长6.0分钟(95%CI 5.2-6.8),>25 mm者为8.0分钟(95%CI 7.1-8.9),对数秩检验<0.01。
  • 胎头会阴距离预测自然分娩的曲线下面积83%(95%CI 77-89%),预测剖宫产的曲线下面积83%(95%CI 74-92%)。
  • 胎头会阴距离≤35 mm者剖宫产7/181(3.9%),>35 mm者9/41(22.0%)(P<.01)。
  • 超声评估胎位为枕前位者占73%;枕前位且胎头会阴距离≤35 mm者剖宫产3/138(2.2%),非枕前位且>35 mm者6/17(35.3%)。
  • 脐动脉pH<7.10在胎头会阴距离≤35 mm者为2/144(1.4%),>35 mm者为8/40(20.0%)(P<.01)。

临床怎么用

  • 作者认为超声有潜力预测第二产程延长产妇的分娩结局,所获信息可指导是否尝试产钳分娩或选择剖宫产、是否需要高年资医师在场以及是否在手术室进行产钳尝试。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Safe management of the second stage of labor is of great importance. Unnecessary interventions should be avoided and correct timing of interventions should be focused. Ultrasound assessment of fetal position and station has a potential to improve the precision in diagnosing and managing prolonged or arrested labors. The decision to perform vacuum delivery is traditionally based on subjective assessment by digital vaginal examination and clinical expertise and there is currently no method of objectively quantifying the likelihood of successful delivery. Prolonged attempts at vacuum delivery are associated with neonatal morbidity and maternal trauma, especially so if the procedure is unsuccessful and a cesarean is performed. OBJECTIVE: The aim of the study was to assess if ultrasound measurements of fetal position and station can predict duration of vacuum extractions, mode of delivery, and fetal outcome in nulliparous women with prolonged second stage of labor. STUDY DESIGN: We performed a prospective cohort study in nulliparous women at term with prolonged second stage of labor in 7 European maternity units from 2013 through 2016. Fetal head position and station were determined using transabdominal and transperineal ultrasound, respectively. Our preliminary clinical experience assessing head-perineum distance prior to vacuum delivery suggested that we should set 25 mm for the power calculation, a level corresponding roughly to +2 below the ischial spines. The main outcome was duration of vacuum extraction in relation to ultrasound measured head-perineum distance with a predefined cut-off of 25 mm, and 220 women were needed to discriminate between groups using a hazard ratio of 1.5 with 80% power and alpha 5%. Secondary outcomes were delivery mode and umbilical artery cord blood samples after birth. The time interval was evaluated using survival analyses, and the outcomes of delivery were evaluated using receiver operating characteristic curves and descriptive statistics. Results were analyzed according to intention to treat. RESULTS: The study population comprised 222 women. The duration of vacuum extraction was shorter in women with head-perineum distance ≤25 mm (log rank test <0.01). The estimated median duration in women with head-perineum distance ≤25 mm was 6.0 (95% confidence interval, 5.2-6.8) minutes vs 8.0 (95% confidence interval, 7.1-8.9) minutes in women with head-perineum distance >25 mm. The head-perineum distance was associated with spontaneous delivery with area under the curve 83% (95% confidence interval, 77-89%) and associated with cesarean with area under the curve 83% (95% confidence interval, 74-92%). In women with head-perineum distance ≤35 mm, 7/181 (3.9%) were delivered by cesarean vs 9/41 (22.0%) in women with head-perineum distance >35 mm (P <.01). Ultrasound-assessed position was occiput anterior in 73%. Only 3/138 (2.2%) fetuses in occiput anterior position and head-perineum distance ≤35 mm vs 6/17 (35.3%) with nonocciput anterior position and head-perineum distance >35 mm were delivered by cesarean. Umbilical cord arterial pH <7.10 occurred in 2/144 (1.4%) women with head-perineum distance ≤35 mm compared to 8/40 (20.0%) with head-perineum distance >35 mm (P < .01). CONCLUSION: Ultrasound has the potential to predict labor outcome in women with prolonged second stage of labor. The information obtained could guide whether vacuum delivery should be attempted or if cesarean is preferable, whether senior staff should be in attendance, and if the vacuum attempt should be performed in the operating theater.

来源:Am J Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Kahrs BH, Usman S, Ghi T, et al. Sonographic prediction of outcome of vacuum deliveries: a multicenter, prospective cohort study. Am J Obstet Gynecol. 2017. PMID: 28327433. doi:10.1016/j.ajog.2017.03.009

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。