剖宫产术中皮肤闭合:胶水与皮内缝合的随机对照试验
该随机对照试验比较剖宫产皮肤闭合使用胶水(Dermabond)与单丝皮内缝合(Monocryl)的伤口并发症与瘢痕愈合,结果显示两组在患者与观察者瘢痕评估量表评分、手术时长、住院时长及手术部位感染或伤口裂开方面均无显著差异,两种方法均安全成功,可根据术者与患者偏好选择。
要点
- 胶水与单丝皮内缝合在剖宫产皮肤闭合中的患者与观察者瘢痕评估量表评分相似。
- 两组手术部位感染、伤口裂开、住院时长及失血量无显著差异。
- 缝合组术者满意度显著更高(P = .003),但两种方法均安全成功。
核心结论
- 使用胶水或单丝合成缝线进行皮肤闭合的结果相似,两种方法对于择期剖宫产后的皮肤闭合均安全成功,可根据术者和患者偏好使用。
研究设计与样本
- 随机对照试验,纳入择期剖宫产孕妇,随机分配至胶水(Dermabond)或单丝合成缝线(Monocryl)闭合表皮,所有患者均缝合皮下组织,结局评估者设盲,术后>8周评估瘢痕。
- 样本量需104名女性以达到80%把握度的临床显著效应。
主要发现
- 手术时长胶水组37 ± 10分钟 vs 缝合组39 ± 13分钟,P = .515。
- 术者对该技术的满意度缝合组显著更高(P = .003)。
- 两组在失血量、手术部位感染、产后住院时长或伤口裂开方面无显著差异。
- 术后8周患者与观察者瘢痕评估量表评分相似,患者P = .710,医生观察者P = .568。
关键数值与推荐
- 主要结局为患者与观察者瘢痕评估量表评分。
- 次要结局包括术者满意度、手术时长、剖宫产后住院时长及手术部位感染或伤口裂开(血肿或血清肿)并发症。
临床怎么用
- 作者结论认为两种方法均安全成功,可根据术者和患者偏好选择使用。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The optimal choice of skin closure at cesarean delivery has not yet been determined. OBJECTIVE: This study compared wound complications and scar healing following cesarean delivery between 2 methods of skin closure: glue (Dermabond; Ethicon, Somerville, NJ) and monofilament (Monocryl; Ethicon) epidermal sutures. STUDY DESIGN: We conducted a randomized controlled trial in which pregnant women undergoing a scheduled cesarean delivery were randomly assigned to skin (epidermis) closure with glue or with a monofilament synthetic suture. The subcutaneous tissue was sutured for all patients. Outcome assessors were blinded to group allocation. Scars were evaluated >8 weeks. Primary outcome measures were Patient and Observer Scar Assessment Scale scores. Secondary outcome measures were surgeon satisfaction, duration of surgery, duration of hospitalization after the cesarean delivery, and complications of surgical site infection or wound disruption (hematoma or seroma). A sample of 104 women was needed to achieve a clinically significant effect with a power of 80%. RESULTS: Demographic characteristics, patients' clinical background, prepregnancy body mass index, and subcutaneous thickness were similar in both groups. Length of surgery between the groups (37 ± 10 minutes for glue vs 39 ± 13 minutes for sutures, P = .515) was similar. Scores immediately after the wound closure were similar for both groups regarding surgeons' time estimate of closure (P = .181) and closure appearance (P = .082). Surgeons' satisfaction with the technique was significantly higher in the suture group (P = .003). No significant differences were found between the groups in blood loss, surgical site infection, length of postpartum hospitalization, or wound disruption. Glue and suture skin closure scores using Patient and Observer Scar Assessment Scale were similar 8 weeks after surgery, at P = .710 for patients and P = .568 for a physician observer. CONCLUSION: Skin closure using glue or a monofilament synthetic suture had similar results. Both methods were shown to be safe and successful for skin closure after a scheduled cesarean delivery and, therefore, can be used based on surgeon and patient preferences.
引用
- Daykan Y, Sharon-Weiner M, Pasternak Y, et al. Skin closure at cesarean delivery, glue vs subcuticular sutures: a randomized controlled trial. Am J Obstet Gynecol. 2017. PMID: 28153666. doi:10.1016/j.ajog.2017.01.009
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。