文献速递妇科

三维能量多普勒超声评估的肌瘤血管化可预测子宫肌瘤生长:一项前瞻性队列研究

Fibroid vascularisation assessed with three-dimensional power Doppler ultrasound is a predictor for uterine fibroid growth: a prospective cohort study.
PubMed 文献 · BJOG · 2017-04-12

在荷兰阿姆斯特丹VU医疗中心门诊连续纳入66例未治疗的前绝经期子宫肌瘤女性,基线和第3、6、12个月行三维能量多普勒超声,分析基线血管指数与12个月时肌瘤体积及年生长率的关系。基线血管指数与12个月肌瘤体积相关(P=0.02),血管指数每增加1%对应12个月时肌瘤体积大7.00 cm³;血管指数也与年生长率相关(P=0.04)。

要点

  • 基线血管指数与12个月肌瘤体积相关(P=0.02)。
  • 血管指数每增加1%,12个月时肌瘤体积大7.00 cm³。
  • 基线血管指数与肌瘤年生长率相关(P=0.04)。

核心结论

  • 在未治疗的子宫肌瘤女性中,基线三维能量多普勒测得的血管指数与12个月时肌瘤绝对体积变化及年生长率相关。

研究设计与样本

  • 前瞻性队列研究,于2012年3月至2014年3月在阿姆斯特丹VU医疗中心门诊连续纳入诊断不超过两个肌瘤且接受期待治疗的前绝经期女性。
  • 共66名女性(平均年龄42岁)完成12个月随访且未接受治疗。
  • 基线和第3、6、12个月行三维超声包括能量多普勒,使用VOCAL软件计算体积和血管参数。

主要发现

  • 基线血管指数与12个月时肌瘤体积相关(P=0.02)。
  • 基线血管指数每增加1%,12个月时肌瘤体积大7.00 cm³。
  • 基线血管指数也与肌瘤年生长率相关(P=0.04)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To analyse fibroid vascularisation measured with three-dimensional (3D) power Doppler in relation to absolute fibroid volume change during 12 months of follow up and in relation to fibroid growth rate per year. DESIGN: A prospective cohort study was performed between March 2012 and March 2014. SETTING: Outpatient clinic of the VU medical centre, Amsterdam. POPULATION OR SAMPLE: All premenopausal women diagnosed with a maximum of two fibroids with expectant management were consecutively included. METHODS: Three-dimensional ultrasound including power Doppler was performed at baseline, 3, 6 and 12 months. Volume and vascular parameters were calculated using VOCAL software. MAIN OUTCOME MEASURES: The relationship between vascular index (VI) at baseline and fibroid volume over time was analysed using linear mixed model analyses for repeated measurements. Second, the relationship between VI at baseline and fibroid growth rate per year was calculated using linear regression analyses. Analyses were adjusted for possible confounders. RESULTS: In all, 66 women (mean age 42 years) completed 12 months of follow up without treatment. Baseline fibroid vascularisation (VI) measured with 3D power Doppler is correlated with fibroid volume at 12 months (P = 0.02 ). An increase of 1% in VI at baseline was associated with a 7.00-cm3 larger fibroid volume at 12 months. Furthermore, vascularisation was also associated with fibroid growth rate per year (P = 0.04). CONCLUSION: In women with uterine fibroids without therapy, baseline vascularisation (VI) measured with 3D power Doppler is correlated with absolute fibroid volume change at 12 months and with fibroid growth rate per year. TWEETABLE ABSTRACT: Fibroid vascularisation correlates with absolute fibroid volume change and fibroid growth rate per year.

来源:BJOG,查看原文。版权归原作者所有。

引用

  1. Nieuwenhuis LL, Keizer AL, Stoelinga B, et al. Fibroid vascularisation assessed with three-dimensional power Doppler ultrasound is a predictor for uterine fibroid growth: a prospective cohort study. BJOG. 2017. PMID: 28211610. doi:10.1111/1471-0528.14608

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。