文献速递产科母胎医学

MRI在胎儿肾脏异常产前诊断中的价值

[Value of MRI in prenatal diagnosis of abnormal fetal kidneys].
PubMed 文献 · Zhonghua Fu Chan Ke Za Zhi · 2016-01-01

回顾性分析2014年12月至2016年3月51例经随访证实胎儿肾脏异常的孕妇的MRI与超声资料,比较异常肾与对侧正常肾的DWI信号及ADC值,并比较MRI与超声诊断准确率。MRI对胎儿肾脏异常形态显示准确,诊断准确率94%(63/67)与超声85%(57/67)无统计学差异(P=0.070)。

要点

  • MRI能准确显示胎儿异常肾脏的形态学特征。
  • 异常肾与对侧正常肾的DWI信号强度及ADC值无统计学显著差异(P分别为0.165和0.184)。
  • MRI与产前超声诊断胎儿肾脏异常的准确率分别为94%(63/67)和85%(57/67),两者无统计学差异(P=0.070)。

核心结论

  • MRI在胎儿肾脏异常的产前诊断和评估中具有重要作用。

研究设计与样本

  • 回顾性分析2014年12月至2016年3月51例经随访证实胎儿肾脏异常的孕妇的临床与MRI资料。
  • 比较异常肾与对侧正常肾、不同个体正常肾与异常肾的DWI信号强度及ADC值,并比较MRI与超声评估胎儿肾脏异常的准确率。

主要发现

  • 异常肾DWI信号强度368±125、ADC值(1.516±0.420)×10⁻³ mm²/s,与对侧正常肾410±125、(1.362±0.251)×10⁻³ mm²/s相比,P分别为0.165和0.184,无统计学显著差异。
  • 正常肾DWI信号强度401±124高于肾囊肿182±40(P<0.01)。
  • 正常肾ADC值(1.306±0.252)×10⁻³ mm²/s低于肾囊肿(2.912±0.235)×10⁻³ mm²/s(P<0.01)和多囊性发育不良肾(1.870±0.654)×10⁻³ mm²/s(P=0.045)。
  • MRI与产前超声诊断胎儿肾脏异常的准确率分别为94%(63/67)和85%(57/67),两者无统计学差异(P=0.070)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Objective: To investigate the value of MRI in the prenatal diagnosis of abnormal fetal kidneys. Methods: From December 2014 to March 2016, 51 women underwent MRI and were confirmed as having fetuses with abnormal fetal kidneys when follow up. Their clinical and MRI profiles were analyzed retrospectively, including MRI manifestation, the fetal kidney signal intensity of diffusion-weighted imaging (DWI) and apparent diffusion coefficient (ADC). The signal intensity of DWI and ADC of the abnormal kidney and the normal opposite kidney, and those of the normal and abnormal kidneys in different individuals were compared. The accuracies of MRI and ultrasound in evaluating abnormal fetal kidneys were also compared. Results: MRI could accurately demonstrate the morphological features of abnormal fetal kidneys. There was no statistically significant difference between DWI signal intensity and ADC value of the abnormal kidney[368 ± 125, (1.516 ± 0.420) × 10-3 mm2/s] and the normal opposite one[410 ± 125, (1.362 ± 0.251) × 10-3 mm2/s], P values were 0.165 and 0.184, respectively. The DWI signal intensity of normal kidneys (401 ± 124) was higher than that of renal cysts (182 ± 40, P <0.01), and the ADC value of normal kidneys[(1.306 ± 0.252) × 10-3 mm2/s] was lower than that of renal cysts[(2.912 ± 0.235) × 10-3 mm2/s] and multicystic dysplastic kidneys[(1.870±0.654) ×10-3 mm2/s], P values were <0.01 and 0.045, respectively. The diagnostic accuracy of MRI and prenatal ultrasound for abnormal fetal kidneys were 94% (63/67) and 85% (57/67), respectively. However, there was no statistical difference between the two methods (P=0.070). Conclusion: MRI have an important role in the prenatal diagnosis and evaluation of abnormal fetal kidneys.

来源:Zhonghua Fu Chan Ke Za Zhi,查看原文。版权归原作者所有。

引用

  1. Liu HD, Yu H, Zhao JG, et al. [Value of MRI in prenatal diagnosis of abnormal fetal kidneys]. Zhonghua Fu Chan Ke Za Zhi. 2016. PMID: 28057124. doi:10.3760/cma.j.issn.0529-567X.2016.12.004

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。