文献速递生殖医学

评估六种已发表的时间-lapse成像胚胎选择算法预测着床的效能,以论证开发特定院内形态动力学选择算法的必要性

Examining the efficacy of six published time-lapse imaging embryo selection algorithms to predict implantation to demonstrate the need for the development of specific, in-house morphokinetic selection algorithms.
PubMed 文献 · Fertil Steril · 2017-01-06

该回顾性观察分析纳入2014年9月至2015年9月共884个IVF/ICSI周期(977枚胚胎),在EmbryoScope中培养,评估六种已发表胚胎选择算法预测着床的效能。结果显示各算法阳性预测值38.29%–44.28%、阴性预测值61.10%–76.19%、AUC 0.543–0.629,仅两种算法分类间着床率差异有统计学意义。作者认为现有算法外部应用时可能失去诊断价值,需开发针对患者、治疗和环境的院内算法。

要点

  • 六种已发表胚胎选择算法在977枚已知着床结局胚胎中AUC为0.543–0.629,预测效能有限。
  • 各算法阳性预测值38.29%–44.28%,阴性预测值61.10%–76.19%。
  • 仅两种算法分类间着床率差异有统计学意义,作者认为现有算法外部应用可能失去诊断价值。

核心结论

  • 结果强调需要开发针对患者、治疗和环境特异的院内胚胎选择算法。
  • 数据提示现有胚胎选择算法在外部应用时可能不具临床适用性并失去诊断价值。

研究设计与样本

  • 回顾性观察分析,纳入2014年9月至2015年9月共884个IVF或ICSI治疗周期(977枚胚胎)。
  • 胚胎在EmbryoScope中以5% O2、89% N2、6% CO2、37°C条件使用G-TL(Vitrolife)培养。
  • 无干预措施,评估六种已发表胚胎选择算法预测着床的效能。

主要发现

  • 六种算法的阳性预测值分别为42.57%、41.52%、44.28%、38.91%、38.29%、40.45%。
  • 六种算法的阴性预测值分别为62.12%、68.26%、71.35%、76.19%、61.10%、64.14%。
  • 六种算法的敏感度分别为16.70%、75.33%、72.94%、98.67%、51.19%、62.33%,特异度分别为85.83%、33.33%、42.33%、2.67%、48.17%、42.33%。
  • 六种算法的AUC分别为0.584、0.558、0.573、0.612、0.543、0.629。
  • 两种胚胎选择算法的胚胎分类间着床率差异有统计学意义(Fisher精确检验和Kruskal-Wallis检验)。

关键数值与推荐

  • 效能评估指标包括特异度、敏感度、阳性预测值、阴性预测值、受试者工作特征曲线下面积(AUC)和似然比(LR)。

临床怎么用

  • 作者认为需要开发针对患者、治疗和环境特异的院内胚胎选择算法。
  • 作者提示现有胚胎选择算法在外部应用时可能不具临床适用性并失去诊断价值。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To study the efficacy of six embryo-selection algorithms (ESAs) when applied to a large, exclusive set of known implantation embryos. DESIGN: Retrospective, observational analysis. SETTING: Fertility treatment center. PATIENT(S): Women undergoing a total of 884 in vitro fertilization (IVF) or intracytoplasmic sperm injection (ICSI) treatment cycles (977 embryos) between September 2014 and September 2015 with embryos cultured using G-TL (Vitrolife) at 5% O2, 89% N2, 6% CO2, at 37°C in EmbryoScope instruments. INTERVENTION(S): None. MAIN OUTCOME MEASURE(S): Efficacy of each ESA to predict implantation defined using specificity, sensitivity, positive predictive value (PPV), negative predictive value (NPV), area under the receiver operating characteristic curve (AUC), and likelihood ratio (LR), with differences in implantation rates (IR) in the categories outlined by each ESA statistically analyzed (Fisher's exact and Kruskal-Wallis tests). RESULT(S): When applied to an exclusive cohort of known implantation embryos, the PPVs of each ESA were 42.57%, 41.52%, 44.28%, 38.91%, 38.29%, and 40.45%. The NPVs were 62.12%, 68.26%, 71.35%, 76.19%, 61.10%, and 64.14%. The sensitivity was 16.70%, 75.33%, 72.94%, 98.67%, 51.19%, and 62.33% and the specificity was 85.83%, 33.33%, 42.33%, 2.67%, 48.17%, and 42.33%, The AUC were 0.584, 0.558, 0.573, 0.612, 0.543, and 0.629. Two of the ESAs resulted in statistically significant differences in the embryo classifications in terms of IR. CONCLUSION(S): These results highlight the need for the development of in-house ESAs that are specific to the patient, treatment, and environment. These data suggest that currently available ESAs may not be clinically applicable and lose their diagnostic value when externally applied.

来源:Fertil Steril,查看原文。版权归原作者所有。

引用

  1. Barrie A, Homburg R, McDowell G, et al. Examining the efficacy of six published time-lapse imaging embryo selection algorithms to predict implantation to demonstrate the need for the development of specific, in-house morphokinetic selection algorithms. Fertil Steril. 2017. PMID: 28069186. doi:10.1016/j.fertnstert.2016.11.014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。