吲哚菁绿激光血管造影评估全腹腔镜子宫切除术中阴道残端灌注的初步研究
该初步可行性试验对20例因良性疾病行全腹腔镜子宫切除术的患者,按1:1随机分配阴道切开能量方式(超声刀 vs 单极)和残端缝合线(倒刺线 vs 非倒刺线),静脉注射吲哚菁绿后行激光血管造影,评估阴道残端灌注。所有患者残端均可见荧光,未发生与静脉注射吲哚菁绿相关的并发症;作者认为该技术可用于评估阴道残端血管灌注,并可能促进未来关于阴道残端裂开原因的前瞻性研究。
要点
- 20例良性病变行全腹腔镜子宫切除术患者中,静脉注射吲哚菁绿后阴道残端均可见荧光。
- 超声刀组开放残端周长67.5%±17.4%、闭合残端长度74.4%±20.5%灌注充分;单极组分别为59.1%±17.4%和66.3%±15.4%。
- 倒刺线组闭合残端长度71.5%±15.1%灌注充分,非倒刺线组为68.9%±20.9%。
核心结论
- 吲哚菁绿激光血管造影可在全腹腔镜子宫切除术中评估阴道残端血管灌注。
- 该技术可能促进未来探讨阴道残端裂开(一种潜在导致严重并发症的情况)原因的前瞻性研究。
研究设计与样本
- 初步可行性试验(加拿大任务组分类II-2),学术附属医院,20例因良性疾病行全腹腔镜子宫切除术的女性。
- 参与者按1:1随机分配阴道切开能量方式(超声刀 vs 单极)和阴道残端缝合线(倒刺线 vs 非倒刺线)。
- 静脉注射吲哚菁绿后,激光血管造影在缝合前后捕获阴道残端图像;三名审阅者分析荧光图像,确定开放时残端周长灌注充分百分比和闭合时残端长度灌注充分比例。
主要发现
- 所有参与者阴道残端均可见吲哚菁绿荧光。
- 给药后吲哚菁绿在盆腔出现平均时间:缝合前19.8±6.8秒,缝合后26.0±22.2秒。
- 超声刀组开放残端周长67.5%±17.4%和闭合残端长度74.4%±20.5%灌注充分,单极组分别为59.1%±17.4%和66.3%±15.4%。
- 倒刺线组闭合残端长度71.5%±15.1%灌注充分,非倒刺线组为68.9%±20.9%。
- 归一化至宫颈杯周长后,超声刀需1.0±0.2秒/毫米,单极需0.8±0.3秒/毫米(p=0.162);线性回归显示归一化能量激活时间与开放残端周长灌注充分百分比(R²=0.007)或闭合残端长度(R²=0.005)无关联;无与静脉注射吲哚菁绿相关的并发症发生。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
STUDY OBJECTIVE: To determine feasibility of using laser angiography with indocyanine green (ICG) to assess vaginal cuff vascular perfusion during total laparoscopic hysterectomy (TLH). DESIGN: Pilot feasibility trial (Canadian Task Force classification II-2). SETTING: Academic-affiliated hospital. PATIENTS: Twenty women undergoing TLH for benign disease. INTERVENTIONS: Participants underwent 1:1 randomization of energy method used for colpotomy (ultrasonic vs monopolar) and vaginal cuff closure suture (barbed vs nonbarbed). After intravenous administration of ICG, laser angiography was used to capture images of the vaginal cuff before and after closure. Three reviewers analyzed fluorescent images of vaginal cuffs to determine percent of cuff perimeter with adequate perfusion when open and length of vaginal cuff adequately perfused when closed. MEASUREMENTS AND MAIN RESULTS: ICG fluorescence was visible at the vaginal cuff in all participants. Mean time to appearance of ICG in the pelvis after administration was 19.8 ± 6.8 seconds (mean ± SD) preclosure, and 26.0 ± 22.2 seconds postclosure. With ultrasonic energy 67.5% ± 17.4% of open cuff perimeter and 74.4% ± 20.5% of closed cuff length were adequately perfused, whereas with monopolar energy use 59.1% ± 17.4% of the open cuff perimeter and 66.3% ± 15.4% of closed cuff length were adequately perfused. Cuffs closed with barbed suture showed adequate perfusion along 71.5% ± 15.1% of the length, whereas those closed with nonbarbed suture showed 68.9% ± 20.9% adequate perfusion. When normalized to cervical cup circumference, ultrasonic energy required 1.0 ± .2 s/mm, whereas monopolar energy required .8 ± .3 s/mm (p = .162). Linear regression showed no association of normalized time of energy activation to percentage of perimeter of open cuff (R2 = .007) or length of closed cuff (R2 = .005) with adequate perfusion. No complications related to intravenous ICG administration occurred. CONCLUSION: Laser angiography with ICG allows evaluation of vascular perfusion at the vaginal cuff during TLH. This technique may facilitate future prospective studies examining causes for vaginal cuff dehiscence, a complication with potential for severe morbidity.