文献速递妇科生殖医学

四维技术在子宫输卵管超声造影中筛查输卵管通畅性的应用:一项探索性研究

Hysterosalpingo-Contrast Sonography With Four-Dimensional Technique for Screening Fallopian Tubal Patency: Let's Make an Exploration.
PubMed 文献 · J Minim Invasive Gynecol · 2016-12-27

本研究为前瞻性观察性研究,纳入204例不孕女性,于2015年7月至2016年6月在浙江大学医学院附属第二医院行四维子宫输卵管超声造影(4D-HyCoSy),并与二维子宫输卵管超声造影(2D-HyCoSy)结果对比。共评估408条输卵管,385条两种方法结果一致,一致率为94.4%。结论认为4D-HyCoSy是筛查输卵管通畅性的可行方法。

要点

  • 4D-HyCoSy与2D-HyCoSy评估输卵管状态的一致率为94.4%(385/408条输卵管)。
  • 4D-HyCoSy可获取动态图像,克服2D-HyCoSy的缺点。
  • 4D-HyCoSy是评估输卵管通畅性的可行筛查方法。

核心结论

  • 4D技术联合子宫输卵管超声造影是评估输卵管通畅性的可行筛查方法,与2D-HyCoSy技术一致率较高。

研究设计与样本

  • 前瞻性观察性研究(加拿大任务组分类II-2),纳入204例不孕女性,于2015年7月至2016年6月在浙江大学医学院附属第二医院行4D-HyCoSy。

主要发现

  • 共评估204例患者的408条输卵管,385条在4D-HyCoSy与2D-HyCoSy上显示相同状态,一致率为94.4%。

关键数值与推荐

  • 4D-HyCoSy过程中若任一输卵管未显影,立即重复操作以排除假阳性结果,随后以传统2D-HyCoSy确认输卵管状态。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

STUDY OBJECTIVE: To evaluate the practicability of transvaginal 4-dimensional (4D) hysterosalpingo-contrast sonography (HyCoSy) using SonoVue for screening of fallopian tube patency in infertile females. DESIGN: Prospective observational study (Canadian Task Force classification II-2). SETTING: The Second Affiliated Hospital of Zhejiang University. PATIENTS: 204 infertile females who underwent 4D-HyCoSy between July 2015 and June 2016. INTERVENTION: 4D-HyCoSy was performed to acquire dynamic images. If any of the fallopian tubes was not developing during the process, the procedure was repeated promptly, to exclude false-positive outcomes. Subsequently, tube status was confirmed by traditional 2-dimensional (2D)-HyCoSy. Finally, the results of the 4D-HyCoSy and the final 2D-HyCoSy were compared. MEASUREMENTS AND MAIN RESULTS: A total of 204 patients (408 tubes) were evaluated ith 4D-HyCoSy followed by 2D-HyCoSy. Of these 408 tubes, 385 demonstrated the same status on 4D-HyCoSy and 2D-HyCoSy, for an agreement rate of 94.4%. CONCLUSION: A 4D technique combined with HyCoSy is a practicable screening method for assessing fallopian tube patency. It overcomes the disadvantages of 2D-HyCoSy and has a relatively high degree of agreement with the more difficult 2D-HyCoSy technique.

来源:J Minim Invasive Gynecol,查看原文。版权归原作者所有。

引用

  1. Chen F, Quan J, Huang P, et al. Hysterosalpingo-Contrast Sonography With Four-Dimensional Technique for Screening Fallopian Tubal Patency: Let's Make an Exploration. J Minim Invasive Gynecol. 2016. PMID: 28034794. doi:10.1016/j.jmig.2016.12.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。